The role of the laser pulse duration in infrared matrix-assisted laser desorption/ionization mass spectrometry

被引:35
作者
Menzel, C [1 ]
Dreisewerd, K [1 ]
Berkenkamp, S [1 ]
Hillenkamp, F [1 ]
机构
[1] Univ Munster, Inst Med Phys & Biophys, D-48149 Munster, Germany
关键词
D O I
10.1016/S1044-0305(02)00397-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The role of the laser pulse duration in matrix-assisted laser desorption/ionization mass spectrometry with infrared lasers (IR-MALDI-MS) emitting in the 3 mum wavelength range has been evaluated. Mass spectrometric performance and characteristics of the IR-MALDI process were examined by comparing a wavelength-tuneable mid-infrared optical parametric oscillator (OPO) laser of 6 ns pulse duration, tuned to wavelengths of 2.79 and 2.94 mum, with an Er:YAG laser (lambda = 2.94 mum) with two pulse durations of 100 and 185 ns, and an Er:YSGG laser (lambda = 2.79 mum) with a pulse duration of 75 ns. Threshold fluences for the desorption of cytochrome C ions were determined as a function of the laser pulse duration for various common IR-MALDI matrices. For the majority of these matrices a reduction in threshold fluence by a factor of 1.2-1.9 was found by going from the 75-100 ns long pulses of the Erbium lasers to the short 6 ns; OPO pulse. Within the experimental accuracy threshold fluences were equal for the 100 and the 185 ns pulse duration of the Er:YAG laser. Some pronounced pulse duration effects related to the ion formation from a glycerol matrix were also observed. The effect of the lasers pulse length on the duration of ion emission was furthermore investigated. (C) 2002 American Society for Mass Spectrometry.
引用
收藏
页码:975 / 984
页数:10
相关论文
共 25 条
[11]   LASER DESORPTION IONIZATION OF PROTEINS WITH MOLECULAR MASSES EXCEEDING 10000 DALTONS [J].
KARAS, M ;
HILLENKAMP, F .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2299-2301
[12]  
Menzel C, 1999, RAPID COMMUN MASS SP, V13, P26, DOI 10.1002/(SICI)1097-0231(19990115)13:1<26::AID-RCM443>3.0.CO
[13]  
2-N
[14]  
MENZEL C, 2001, P 49 ASMS C AM SOC M, V207, P73
[15]   Direct comparison of infrared and ultraviolet wavelength matrix-assisted laser desorption/ionization mass spectrometry of proteins [J].
Niu, SF ;
Zhang, WZ ;
Chait, BT .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (01) :1-7
[16]   MATRIX-ASSISTED INFRARED-LASER (2.94-MU-M) DESORPTION IONIZATION MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
OVERBERG, A ;
KARAS, M ;
BAHR, U ;
KAUFMANN, R ;
HILLENKAMP, F .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (08) :293-296
[17]   MATRIX-ASSISTED LASER DESORPTION OF LARGE BIOMOLECULES WITH A TEA-CO2-LASER [J].
OVERBERG, A ;
KARAS, M ;
HILLENKAMP, F .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (03) :128-131
[18]  
Sadeghi M, 1997, RAPID COMMUN MASS SP, V11, P393, DOI 10.1002/(SICI)1097-0231(19970228)11:4<393::AID-RCM868>3.0.CO
[19]  
2-S
[20]  
Sheffer JD, 1998, RAPID COMMUN MASS SP, V12, P1685, DOI 10.1002/(SICI)1097-0231(19981130)12:22<1685::AID-RCM389>3.0.CO