The role of the laser pulse duration in infrared matrix-assisted laser desorption/ionization mass spectrometry

被引:35
作者
Menzel, C [1 ]
Dreisewerd, K [1 ]
Berkenkamp, S [1 ]
Hillenkamp, F [1 ]
机构
[1] Univ Munster, Inst Med Phys & Biophys, D-48149 Munster, Germany
关键词
D O I
10.1016/S1044-0305(02)00397-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The role of the laser pulse duration in matrix-assisted laser desorption/ionization mass spectrometry with infrared lasers (IR-MALDI-MS) emitting in the 3 mum wavelength range has been evaluated. Mass spectrometric performance and characteristics of the IR-MALDI process were examined by comparing a wavelength-tuneable mid-infrared optical parametric oscillator (OPO) laser of 6 ns pulse duration, tuned to wavelengths of 2.79 and 2.94 mum, with an Er:YAG laser (lambda = 2.94 mum) with two pulse durations of 100 and 185 ns, and an Er:YSGG laser (lambda = 2.79 mum) with a pulse duration of 75 ns. Threshold fluences for the desorption of cytochrome C ions were determined as a function of the laser pulse duration for various common IR-MALDI matrices. For the majority of these matrices a reduction in threshold fluence by a factor of 1.2-1.9 was found by going from the 75-100 ns long pulses of the Erbium lasers to the short 6 ns; OPO pulse. Within the experimental accuracy threshold fluences were equal for the 100 and the 185 ns pulse duration of the Er:YAG laser. Some pronounced pulse duration effects related to the ion formation from a glycerol matrix were also observed. The effect of the lasers pulse length on the duration of ion emission was furthermore investigated. (C) 2002 American Society for Mass Spectrometry.
引用
收藏
页码:975 / 984
页数:10
相关论文
共 25 条
[1]  
Berkenkamp S, 1997, RAPID COMMUN MASS SP, V11, P1399
[2]   Infrared MALDI mass spectrometry of large nucleic acids [J].
Berkenkamp, S ;
Kirpekar, F ;
Hillenkamp, F .
SCIENCE, 1998, 281 (5374) :260-262
[3]  
Caldwell KL, 1997, J MASS SPECTROM, V32, P1374, DOI 10.1002/(SICI)1096-9888(199712)32:12<1374::AID-JMS600>3.0.CO
[4]  
2-Y
[5]   Infrared matrix-assisted laser desorption and ionization by using a tunable mid-infrared free-electron laser [J].
Cramer, R ;
Hillenkamp, F ;
Haglund, RF .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (12) :1187-1193
[6]   Analysis of phospho- and glycopolypeptides with infrared matrix-assisted laser desorption and ionization [J].
Cramer, R ;
Richter, WJ ;
Stimson, E ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4939-4944
[7]  
Cramer R, 2000, RAPID COMMUN MASS SP, V14, P53
[8]   Matrix-assisted laser desorption/ionization with nitrogen lasers of different pulse widths [J].
Dreisewerd, K ;
Schurenberg, M ;
Karas, M ;
Hillenkamp, F .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1996, 154 (03) :171-178
[9]  
Feldhaus D, 2000, J MASS SPECTROM, V35, P1320, DOI 10.1002/1096-9888(200011)35:11<1320::AID-JMS66>3.0.CO
[10]  
2-S