Simultaneous voltammetric determination of paracetamol and ascorbic acid using a boron-doped diamond electrode modified with Nafion and lead films

被引:60
作者
Tyszczuk-Rotko, Katarzyna [1 ]
Beczkowska, Ilona [1 ]
Wojciak-Kosior, Magdalena [2 ]
Sowa, Ireneusz [2 ]
机构
[1] Marie Curie Sklodowska Univ, Fac Chem, Dept Analyt Chem & Instrumental Anal, PL-20031 Lublin, Poland
[2] Med Univ Lublin, Dept Analyt Chem, Chair Chem, PL-20093 Lublin, Poland
关键词
Differential pulse voltammetry; Boron-doped diamond electrode; Nafion and lead films; Paracetamol and ascorbic acid determination; STRIPPING VOLTAMMETRY; ACETAMINOPHEN; OXIDATION; DOPAMINE;
D O I
10.1016/j.talanta.2014.06.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper describes the fabrication and application of a novel sensor (a boron-doped diamond electrode modified with Nafion and lead films) for the simultaneous determination of paracetamol and ascorbic acid by differential pulse voltammetry. The main advantage of the lead film and polymer covered boron-doped diamond electrode is that the sensitivity of the stripping responses is increased and the separation of paracetamol and ascorbic acid signals is improved due to the modification of the boron-doped diamond surface by the lead layer. Additionally, the repeatability of paracetamol and ascorbic acid signals is improved by the application of the Nafion film coating. In the presence of oxygen, linear calibration curves were obtained in a wide concentration range from 5 x 10(-7) to 2 x 10(-4) mol L-1 for paracetamol and from 1 x 10(-6) to 5 x 10(-4) mol L-1 for ascorbic acid. The analytical utility of the differential pulse voltammetric method elaborated was tested in the assay of paracetamol and ascorbic acid in commercially available pharmaceutical formulations and the method was validated by high performance liquid chromatography coupled with diode array detector. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:384 / 391
页数:8
相关论文
共 34 条
  • [11] Carbon Nanotube Based Sensor for Simultaneous Determination of Acetaminophen and Ascorbic Acid Exploiting Multiple Response Optimization and Measures in the Presence of Surfactant
    Duarte, Eduardo Henrique
    Kubota, Lauro Tatsuo
    Teixeira Tarley, Cesar Ricardo
    [J]. ELECTROANALYSIS, 2012, 24 (12) : 2291 - 2301
  • [12] Development and validation of a liquid chromatographic method for the determination of ascorbic acid, dehydroascorbic acid and acetaminophen in pharmaceuticals
    Gioia, M. G.
    Andreatta, P.
    Boschetti, S.
    Gatti, R.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (02) : 331 - 339
  • [13] Differential pulse voltammetric simultaneous determination of acetaminophen and ascorbic acid using single-walled carbon nanotube-modified carbon-ceramic electrode
    Habibi, Biuck
    Jahanbakhshi, Mojtaba
    Pournaghi-Azar, Mohammad Hossein
    [J]. ANALYTICAL BIOCHEMISTRY, 2011, 411 (02) : 167 - 175
  • [14] Simultaneous determination of uric acid and ascorbic acid using glassy carbon electrodes in acetate buffer solution
    John, SA
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 579 (02): : 249 - 256
  • [15] A study of Nafion-coated bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry
    Kefala, G
    Economou, A
    Voulgaropoulos, A
    [J]. ANALYST, 2004, 129 (11) : 1082 - 1090
  • [16] Adsorptive stripping voltammetry of nickel and cobalt at in situ plated lead film electrode
    Korolczuk, M
    Tyszczuk, K
    Grabarczyk, M
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (12) : 1185 - 1189
  • [17] Modification of electrodes using conductive porous layers to confer selectivity for the voltammetric detection of paracetamol in the presence of ascorbic acid, dopamine and uric acid
    Kutluay, Aysegul
    Aslanoglu, Mehmet
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 185 : 398 - 404
  • [18] Electroanalytical applications of boron-doped diamond microelectrode arrays
    Lawrence, Nathan S.
    Pagels, Markus
    Meredith, Andrew
    Jones, Timothy G. J.
    Hall, Clive E.
    Pickles, C. S. Jim
    Godfried, Herman P.
    Banks, Craig E.
    Compton, Richard G.
    Jiang, Li
    [J]. TALANTA, 2006, 69 (04) : 829 - 834
  • [19] Comparison of paracetamol-induced hepatotoxicity in the rat in vivo with progression of cell injury in vitro in rat liver slices
    Martin, FL
    McLean, AEM
    [J]. DRUG AND CHEMICAL TOXICOLOGY, 1998, 21 (04) : 477 - 494
  • [20] Maslarska V., 2013, INT J PHARM PHARM SC, V5, P417