Low-Cycle-Fatigue (LCF) behavior and cyclic plasticity modeling of E250A mild steel

被引:20
作者
Narendra, Perumalla V. R. [1 ]
Prasad, Kartik [2 ]
Krishna, Ede Hari [2 ]
Kumar, Vikas [2 ]
Singh, Konjengbam Darunkumar [1 ]
机构
[1] Indian Inst Technol Guwahati, Dept Civil Engn, Gauhati, India
[2] DRDO, Def Met Res Lab, Hyderabad, Deccan, India
关键词
Low-Cycle-Fatigue (LCF); E250A constructional mild steel; Basquin-Coffin-Manson; Non-Linear Combined Hardening Material (NLCHM) model; Abaqus; STAINLESS-STEEL; HIGH-STRENGTH; MATERIAL PARAMETERS; FRACTURE-TOUGHNESS; STRUCTURAL-STEEL; PREDICTION; DAMAGE; OPTIMIZATION; PERFORMANCE; SIMULATION;
D O I
10.1016/j.istruc.2019.06.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A series of strain-controlled fully-reversed uni-axial tension-compression Low-Cycle-Fatigue (LCF) tests are carried out on IS 2062:E250A (Fe410W-A) mild steel specimens with strain amplitudes upto +/- 1.2%, to study the cyclic in-elastic material behavior. Accordingly, parameters of Cyclic-Stress-Strain (CSS) and Basquin-CoffinManson relationships are derived using the LCF test results. Further, the calibration of Non-Linear Combined (isotropic-kinematic) Hardening Material (NLCHM) model of cyclic plasticity is illustrated based on the experimental hysteresis response data. Finally, the efficiency of the calibrated NLCHM model parameters is substantiated by accurately simulating the material response from the tests conducted, using a non-linear FE software, Abaqus.
引用
收藏
页码:594 / 606
页数:13
相关论文
共 103 条
  • [21] ASTM, 2014, A3636M14 ASTM
  • [22] Determination of combined hardening material parameters under strain controlled cyclic loading by using the genetic algorithm method
    Badnava, H.
    Pezeshki, S. M.
    Nejad, Kh. Fallah
    Farhoudi, H. R.
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (10) : 3067 - 3072
  • [23] Low cycle fatigue behaviour of structural steel members and connections
    Ballio, G
    Calado, L
    Castiglioni, CA
    [J]. FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 1997, 20 (08) : 1129 - 1146
  • [24] Basquin O. H., 1910, Proc Am Soc Test Mater, V10, P625
  • [25] Bauschinger J., 1886, Mittheilungen aus dem Mechanisch- Technischen Laboratorium der Koniglichen Technischen Hochschule in Munchen, V13, P1
  • [26] Bernuzzi C., 2000, ISET J EARTHQ TECHNO, V37, P47
  • [27] Bhowmick A., 2016, INT J INNOV TECHNOL, V4, P2955
  • [28] Boardman B., 1990, ASM HDB PROPERTIES S, V1, P673
  • [29] The Chaboche nonlinear kinematic hardening model: calibration methodology and validation
    Broggiato, Giovanni B.
    Campana, Francesca
    Cortese, Luca
    [J]. MECCANICA, 2008, 43 (02) : 115 - 124
  • [30] Canadian Standards Association (CSA), 2013, CSA g40.20-13/g40.21-13