A New Mixture Refrigerant for Space Heating Air Source Heat Pump: Theoretical Modelling and Performance Analysis

被引:8
作者
Kong, Xiangrui [1 ]
Zhang, Yufeng [1 ]
Nie, Jinzhe [2 ]
机构
[1] Tianjin Univ, Sch Architecture, Tianjin 300072, Peoples R China
[2] Beijing Univ Civil Engn & Architecture, Beijing Key Lab Heating Gas Supply Ventilating &, Beijing 100044, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2018年 / 8卷 / 04期
基金
中国国家自然科学基金;
关键词
air source heat pump; HFC refrigerant; global warming potential; space heating; LOW-GWP ALTERNATIVES; WATER-HEATER; R410A; R22; OPTIMIZATION; SIMULATION; POLLUTION; R404A; R407C;
D O I
10.3390/app8040622
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Air source heat pump (ASHP) is becoming a substitute for small coal boilers in rural residential buildings of North China. However, the application of ASHP faces challenges of heating capacity, energy efficiency, ozone depletion potential (ODP) and global warming potential (GWP). Proper refrigerant is a key factor influences the performance of ASHP. In this paper, a new mixture refrigerant named RHR-1 is proposed, which aimed to improve energy efficiency, eliminate ODP and reduce GWP of ASHP refrigerant. The performance of RHR-1 was analyzed and compared with commonly used refrigerants including R134a, R410A, R407C and R22 in terms of heating coefficient of performance (COPh), compression ratio (CR) and discharging temperature (DT). The results show that, under the design cases, where supply water temperatures vary from 35 degrees C to 50 degrees C and outdoor air temperatures vary from 15 degrees C to 15 degrees C, the COPh of RHR-1 are in the range of 2.43-4.93. The COPh of RHR-1 is higher than other candidates when the supply water temperature is above 40 degrees C. The CR and DT of RHR-1 are in medium levels of the compared samples. A logarithmic regression equation was deduced to get the relationship of COPh with temperature difference between supply water and outdoor air which suggested the temperature difference should be controlled within 47.5 degrees C to get reasonable COPh. In addition, RHR-1 has no ODP, and its GWP is 279, which is much lower than other candidates. RHR-1 could be a reasonable refrigerant used in ASHP for space heating in North China.
引用
收藏
页数:16
相关论文
共 38 条
[1]   Testing, simulation and soft-optimization of R410A low-GWP alternatives in heat pump system [J].
Alabdulkarem, Abdullah ;
Eldeeb, Radia ;
Hwang, Yunho ;
Aute, Vikrant ;
Radermacher, Reinhard .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 60 :106-117
[2]   Performance investigation of ozone-friendly R404A and R507 refrigerants as alternatives to R22 in a window air-conditioner [J].
Bolaji, Bukola Olalekan .
ENERGY AND BUILDINGS, 2011, 43 (11) :3139-3143
[3]   Modelling the Contribution of Domestic Heat Pumps to Delivering UK Energy Policy Objectives [J].
Braun, David ;
Rowley, Paul .
APPLIED SCIENCES-BASEL, 2013, 3 (02) :338-354
[4]   Experimental evaluation of a vapour compression plant performance using R134a, R407C and R22 as working fluids [J].
Cabello, R ;
Torrella, E ;
Navarro-Esbrí, J .
APPLIED THERMAL ENGINEERING, 2004, 24 (13) :1905-1917
[5]  
Calm JM, 2011, CONGRES INT FROID, V23, P4120
[6]   Assessment for central heating systems with different heat sources: A case study [J].
Chen Chengmin ;
Zhang Yufeng ;
Ma Lijun .
ENERGY AND BUILDINGS, 2012, 48 :168-174
[7]   A comparative study on the performance and environmental characteristics of R410A and R22 residential air conditioners [J].
Chen, W. .
APPLIED THERMAL ENGINEERING, 2008, 28 (01) :1-7
[8]  
Chen Y., 2015, CHINA INDOOR AIR, V26, P246
[9]   Advances in heat pump systems: A review [J].
Chua, K. J. ;
Chou, S. K. ;
Yang, W. M. .
APPLIED ENERGY, 2010, 87 (12) :3611-3624
[10]   Simulation of Hybrid Photovoltaic Solar Assisted Loop Heat Pipe/Heat Pump System [J].
Dai, Nannan ;
Xu, Xinyi ;
Li, Shuhong ;
Zhang, Zheng .
APPLIED SCIENCES-BASEL, 2017, 7 (02)