Advancements in accuracy of the alanine dosimetry system. Part 2. The influence of the irradiation temperature

被引:57
|
作者
Nagy, V [1 ]
Puhl, JM [1 ]
Desrosiers, MF [1 ]
机构
[1] Natl Inst Stand & Technol, Ionizing Radiat Div, Gaithersburg, MD 20899 USA
关键词
alanine; EPR dosimetry; temperature coefficient;
D O I
10.1016/S0969-806X(99)00339-4
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Systematic measurements of the temperature coefficient for alanine electron paramagnetic resonance (EPR) response have been performed for irradiation in the temperature range (10-50)degrees C and in the absorbed dose range (1-100) kGy at the dose rate 9.5 kGy/h. During the Co-60(.)-ray irradiation, (.)-L-alanine dosimeters were kept in a sealed aluminum holder that provided an effective heat exchange with the temperature-controlled environment. The time between the irradiation and signal measurements was standardized, and a reference sample fixed in the resonant cavity was used to correct the signals for small variations in the spectrometer sensitivity. The temperature coefficient for each dose was determined from approximately 30 experimental points processed by the weighted least-squares technique after the necessary statistical tests were done. The temperature coefficients thus determined were considerably lower than previously reported. The dose dependence of the temperature coefficient features a minimum at (20-30) kGy (about 0.135%/K) with higher values at 1 kGy (0.17%/K) and at 100 kGy ((0.175-0.19) %/K). With the exception of very high doses, no significant distinction was found between the temperature coefficients of Bruker and NIST dosimeters, which differ in shape and binder content. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [1] Advancements in accuracy of the alanine dosimetry system. Part 1. The effects of environmental humidity
    Sleptchonok, OF
    Nagy, V
    Desrosiers, MF
    RADIATION PHYSICS AND CHEMISTRY, 2000, 57 (02) : 115 - 133
  • [2] Advancements in accuracy of the alanine EPR dosimetry system Part III: Usefulness of an adjacent reference sample
    Nagy, V
    Sleptchonok, OF
    Desrosiers, MF
    Weber, RT
    Heiss, AH
    RADIATION PHYSICS AND CHEMISTRY, 2000, 59 (04) : 429 - 441
  • [3] The impact of irradiation temperature estimations on the accuracy of dosimetry
    Desrosiers, M. F.
    Ostapenko, T.
    Puhl, J. M.
    RADIATION PHYSICS AND CHEMISTRY, 2009, 78 (7-8) : 457 - 460
  • [5] Is there an influence of the surrounding material on the response of the alanine dosimetry system?
    Anton, Mathias
    Kapsch, Ralf-Peter
    Hackel, Thomas
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07): : 2029 - 2035
  • [6] Evaluation of an improved orthognathic articulator system. 2. Accuracy of occlusal wafers
    Paul, P. E.
    Barbenel, J. C.
    Walker, F. S.
    Khambay, B. S.
    Moos, K. F.
    Ayoub, A. F.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 41 (02) : 155 - 159
  • [7] NONUNIFORM IRRADIATION OF THE CANINE INTESTINE .2. DOSIMETRY
    ZEMAN, GH
    MOHAUPT, TH
    TAYLOR, PL
    MACVITTIE, TJ
    DUBOIS, A
    VIGNEULLE, RM
    RADIATION RESEARCH, 1990, 121 (01) : 54 - 62
  • [8] INFLUENCE OF THE IRRADIATION TEMPERATURE ON THE FREE-RADICAL RESPONSE OF ALANINE
    WIESER, A
    SIEGELE, R
    REGULLA, DF
    APPLIED RADIATION AND ISOTOPES, 1989, 40 (10-12) : 957 - 959
  • [9] Development of an open parallel intelligent CNC milling system. Part 2. Milling experiment
    Liu, Y
    Cheng, T
    Zuo, L
    Wang, C
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2000, 16 (08): : 542 - 546
  • [10] Development of an Open Parallek Intelligent CNC Milling System. Part 2. Milling Experiment
    Y. Liu
    T. Cheng
    L. Zuo
    C. Wang
    The International Journal of Advanced Manufacturing Technology, 2000, 16 : 542 - 546