Temperature Induced Inaccuracy in Composite Piezoresistive Micro/nano Cantilever Chemical/biological Sensors

被引:0
|
作者
Mathew, Ribu [1 ]
Sankar, A. Ravi [2 ]
机构
[1] VIT Bhopal Univ, Sch Elect & Elect Engn SEEE, Bhopal, India
[2] VIT Chennai, Sch Elect Engn SENSE, Chennai, Tamil Nadu, India
来源
2018 IEEE SENSORS | 2018年
关键词
Joule heating; thermal drift; micro/nano cantilever; surface stress; piezoresistor; sensor; DESIGN;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Over the years, piezoresistive micro/nano cantilevers have been explored as sensing platforms for realizing chemical/biological sensors. Even though, literature encompasses various design examples of such sensors, seldom a major limitation-joule heating induced thermal drift in sensor output is considered in the modeling and design stages. In this paper, we model and design a piezoresistive micro/nano cantilever surface stress sensor considering thermal drift component and estimate the temperature induced inaccuracy in the sensor output. The composite sensor design is performed at both material and geometric levels considering the interdependence between mechanical, thermal and electrical design variables. Results depict that the magnitude of thermal drift in sensor output is higher than the desired signal. Thus, thermal drift has detrimental impact on sensor measurement reliability. Simulation results show that the major component of thermal drift i.e. TCE induced cantilever defection increases at higher immobilization layer thickness and dc-bias voltage. Therefore, to obtain higher sensitivity ratio (electrical sensitivity to thermal sensitivity), lower immobilization layer thickness along with reduced bias voltage should be used. The present work has wide implications since it provides an in-sight into the modeling and design of piezoresistive micro/nano cantilevers with thermal drift phenomenon demonstrating the need for thermal drift aware design of such sensors.
引用
收藏
页码:247 / 250
页数:4
相关论文
共 50 条
  • [21] A thermal-driven silicon micro xy-stage integrated with piezoresistive sensors for nano-positioning
    Choi, Young-Soo
    Zhang, Yan
    Lee, Dong-Weon
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2012, 22 (05)
  • [22] Variability Induced Sensitivity Degradation in Coupled Nano/Micro Resonant Sensors
    Tao, Guowei
    Choubey, Bhaskar
    IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2018, 17 (04) : 709 - 713
  • [23] Evaluation of static measurement in piezoelectric cantilever sensors using a charge integration technique for chemical and biological detection
    Isarakorn, D.
    Linder, M.
    Briand, D.
    de Rooij, N. F.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (07)
  • [24] Integrated Resonant Micro/Nano Gravimetric Sensors for Bio/Chemical Detection in Air and Liquid
    Jia, Hao
    Xu, Pengcheng
    Li, Xinxin
    MICROMACHINES, 2021, 12 (06)
  • [25] Micro- and Nano-Structured Metal Oxides Based Chemical Sensors: An Overview
    Batra, Ashok K.
    Chilvery, A. K.
    Guggilla, Padmaja
    Aggarwal, Mohan
    Currie, James R., Jr.
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2014, 14 (02) : 2065 - 2085
  • [26] Dual-Mode Bioenabled Nano-Plasmonic Sensors for Biological and Chemical Detection
    Kong, Xianming
    Squire, Kenny
    Xi, Yuting
    LeDuff, Paul
    Rorrer, Gregory L.
    Wang, Alan X.
    FRONTIERS IN BIOLOGICAL DETECTION: FROM NANOSENSORS TO SYSTEMS VIII, 2016, 9725
  • [27] Fiber Optic Chemical and Biological Sensors: Perspectives and Challenges Approaching the Nano-Era
    Cusano, Andrea
    Cutolo, Antonello
    Giordano, Michele
    CURRENT ANALYTICAL CHEMISTRY, 2008, 4 (04) : 271 - 272
  • [28] High-Tactile Sensitivity of Piezoresistive Sensors With a Micro-Crack Structure Induced by Thin Film Tension
    Chen, Longlong
    Feng, Jiayu
    Li, Tongkuai
    Li, Xifeng
    Zhang, Jianhua
    IEEE ELECTRON DEVICE LETTERS, 2019, 40 (09) : 1519 - 1521
  • [29] Morphology Tailoring of Nano/Micro-Structured Conductive Polymers, Composites and their Applications in Chemical Sensors
    Ma, Xingfa
    Gao, Mingjun
    He, Xiaochun
    Li, Guang
    RECENT PATENTS ON NANOTECHNOLOGY, 2010, 4 (03) : 150 - 163
  • [30] Silicon micro-cantilever chemical sensors fabricated in double-layer silicon-on-insulator (SOI) wafer
    Chen, Chuanzhao
    Chen, Ying
    Xu, Pengcheng
    Li, Xinxin
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2016, 22 (08): : 1959 - 1965