Development of In Vivo Measurement System for Temperature Rise in Animal Tissue under Exposure to Ultrasound with Acoustic Radiation Force

被引:1
|
作者
Nitta, Naotaka [1 ]
Kudo, Nobuki [2 ]
Kamakura, Tomoo [3 ]
Ishiguro, Yasunao [4 ]
Sasanuma, Hideki [4 ]
Taniguchi, Nobuyuki [4 ]
Akiyama, Iwaki [4 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Human Technol Res Inst, Tsukuba, Ibaraki, Japan
[2] Hokkaido Univ, Grad Sch Informat Sci & Technol, Lab Biomed Engn, Sapporo, Hokkaido 060, Japan
[3] Univ Elect Commun, Grad Sch Informat & Engn, Tokyo, Japan
[4] Jichi Med Univ, Tokyo, Japan
来源
2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2013年
关键词
acoustic radiation force; temperature rise; measurement system; SOFT-TISSUE;
D O I
10.1109/ULTSYM.2013.0100
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Acoustic radiation force (ARF) has been recently used for the tissue elasticity measurement and imaging. On the other hand, it is predicted that the higher temperature rises occur. In vivo measurement of temperature rise in animal experiments is important, whereas the measurement using thermocouples have some problems such as position mismatch of a temperature measuring junction of thermocouple and a focal point of ultrasound and so on. Therefore, in vivo measurement system for solving the above problems was developed in this study. The feasibility of the developed system was verified by the experiments using a tissue mimicking materials (TMM), TMM with a bone mode, an extracted porcine liver and a bone of chicken. Moreover, relations between conditions of ultrasound irradiation and temperature rises were investigated using the system. These results showed that temperature rises at focus on the surface of bone may exceed an allowable temperature rise which WFUMB guideline recommends, even though the acoustic intensity is within the limits of acoustic output regulation in diagnostic ultrasound devices.
引用
收藏
页码:386 / 389
页数:4
相关论文
共 24 条
  • [21] Acoustic Radiation Force Impulse imaging of in vivo vastus medialis muscle under varying isometric load
    Nightingale, K
    Nightingale, R
    Stutz, D
    Trahey, G
    ULTRASONIC IMAGING, 2002, 24 (02) : 100 - 108
  • [22] The arrhythmogenic effect of ultrasonic exposure with acoustic radiation force (ARF) impulse on the rabbit heart with ultrasound contrast agent perfluorobutane
    Yasunao Ishiguro
    Hideki Sasanuma
    Naotaka Nitta
    Nobuyuki Taniguchi
    Yukiyo Ogata
    Yoshikazu Yasuda
    Iwaki Akiyama
    Journal of Medical Ultrasonics, 2015, 42 : 47 - 50
  • [23] The arrhythmogenic effect of ultrasonic exposure with acoustic radiation force (ARF) impulse on the rabbit heart with ultrasound contrast agent perfluorobutane
    Ishiguro, Yasunao
    Sasanuma, Hideki
    Nitta, Naotaka
    Taniguchi, Nobuyuki
    Ogata, Yukiyo
    Yasuda, Yoshikazu
    Akiyama, Iwaki
    JOURNAL OF MEDICAL ULTRASONICS, 2015, 42 (01) : 47 - 50
  • [24] In-vivo Assessing the Age-Related Stiffness of Crystalline Lens in Rabbits by Acoustic Radiation Force based Ultrasound Elastography
    Wang, Qingmin
    Lv, Zhen
    Gao, Xuehua
    Zhang, Pengpeng
    Lin, Haoming
    Guo, Yanrong
    Chen, Xin
    Wang, Tianfu
    Chen, Siping
    Zhang, Xinyu
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,