Silicon Mach-Zehnder interferometer racetrack microring for sensing

被引:2
|
作者
Xiong, Yule [1 ]
Ye, Winnie N. [1 ]
机构
[1] Carleton Univ, Dept Elect, Ottawa, ON K1S 5B6, Canada
来源
SILICON PHOTONICS IX | 2014年 / 8990卷
关键词
microring resonator; Mach-Zehnder interferometer; multimode interference; sensing; RING-RESONATOR;
D O I
10.1117/12.2037405
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
SOI-based microring resonators (MRRs) have attracted extensive attentions as ultra-compact sensors. Recently, a new structure design combining a ring and a Mach-Zehnder interferometer (MZI) was proposed as sensors for biomedical applications, and as modulators for communications applications. In this design, the MZI uses two identical couplers, where one arm is formed by connecting the access waveguide of the couplers, while the other arm is part of the microring. Such a device may have only one major resonance with a high extinction ratio in a very broad wavelength span (quasi-free spectral range, quasi-FSR), which offers a very large measurement range for sensing applications. 2x2 multimode interference (MMI) couplers are used to couple the microring and the bus waveguides as MMI couplers have broader wavelength responses. We present the first experimental demonstration of the MMI-coupled MZI racetrack microrings for sensing applications. Two types of MMI-coupled MZI racetrack microrings are discussed: one with wire waveguides, and the other using slotted waveguides. For the MZI racetrack microring using wire waveguides, we achieve a quasi-FSR of 34.3 nm near the wavelength of 1520 nm. The corresponding major resonance of the MZI racetrack microring demonstrates a high extinction ratio of similar to 22.4 dB with a full-width-half-maximum (FWHM) of 1.94 nm, and a quality factor Q of similar to 800. On the other hand, the quasi-FSR of the MZI racetrack microring with slot waveguides is 23.2 nm near the wavelength of 1540 nm; and the extinction ratio of the major resonance is similar to 24.5 dB with lambda(FWHM)=0.82 nm and Q=similar to 1,900. To demonstrate the uses for sensing applications, we measure the resonance shifts corresponding to the concentration change of the ambient aqueous solutions of sucrose. DI water is used as the reference for calibration to avoid any other variations, e. g. temperature change. Experiments show that the sensitivities of the MZI racetrack microring sensors with wire and slot waveguides are 101.7 nm/RIU and 166.7 nm/RIU, respectively.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] A modified Sagnac/Mach-Zehnder interferometer for distributed disturbance sensing
    Chtcherbakov, AA
    Swart, PL
    Spammer, SJ
    Lacquet, BM
    FOURTH PACIFIC NORTHWEST FIBER OPTIC SENSOR WORKSHOP, 1998, 3489 : 60 - 64
  • [32] DC current sensing capability of microfibre Mach-Zehnder interferometer
    Sulaiman, A.
    Harun, S. W.
    Aryangar, I.
    Ahmad, H.
    ELECTRONICS LETTERS, 2012, 48 (15) : 943 - 945
  • [33] Design of Mach-Zehnder Interferometer and Ring Resonator for Biochemical Sensing
    Irawan, Dedi
    Saktioto, Toto
    Ali, Jalil
    Yupapin, Preecha
    PHOTONIC SENSORS, 2015, 5 (01) : 12 - 18
  • [34] A Mach-Zehnder interferometer based on silicon oxides for biosensor applications
    Hong, Jongin
    Choi, Jung Sung
    Han, Gayoung
    Kang, Jae Kwang
    Kim, Chang-Min
    Kim, Tae Song
    Yoon, Dae Sung
    ANALYTICA CHIMICA ACTA, 2006, 573 : 97 - 103
  • [35] Vertical Plasmonic Mach-Zehnder interferometer for sensitive optical sensing
    Gan, Qiaoqiang
    Gao, Yongkang
    Bartoli, Filbert J.
    OPTICS EXPRESS, 2009, 17 (23): : 20747 - 20755
  • [36] Photonic Crystal Fiber Mach-Zehnder Interferometer pH Sensing
    Mohammed, Ayad Z.
    4TH ELECTRONIC AND GREEN MATERIALS INTERNATIONAL CONFERENCE 2018 (EGM 2018), 2018, 2045
  • [37] Nested ring Mach-Zehnder interferometer
    Darmawan, S.
    Landobasa, Y. M.
    Chin, M. K.
    OPTICS EXPRESS, 2007, 15 (02): : 437 - 448
  • [38] MACH-ZEHNDER INTERFEROMETER AS AN INSTRUCTIONAL TOOL
    NACHMAN, P
    AMERICAN JOURNAL OF PHYSICS, 1995, 63 (01) : 39 - 43
  • [39] Coupling-induced phase shift in a microring-coupled Mach-Zehnder interferometer
    Darmawan, S.
    Tobing, Landobasa Y. M.
    Mei, T.
    OPTICS LETTERS, 2010, 35 (02) : 238 - 240
  • [40] Coherence and contextuality in a Mach-Zehnder interferometer
    Wagner, Rafael
    Camillini, Anita
    Galvao, Ernesto F.
    QUANTUM, 2024, 8