Monitoring and estimation of the kinetics parameters in the binding process of tannic acid to bovine serum albumin with electrochemical quartz crystal impedance system

被引:16
|
作者
Liu, Meiling [1 ]
Zhang, Youyu [1 ]
Yang, Qin [1 ]
Xie, Qingji [1 ]
Yao, Shouzhuo [1 ]
机构
[1] Hunan Normal Univ, Coll Chem & Chem Engn, Minist Educ, Key Lab Chem Biol & Trad Chinese Med Res, Changsha 410081, Peoples R China
关键词
tannic acid; bovine serum albumin; piezoelectric quartz crystal impedance; electrochemical impedance; electrochemical piezoelectric quartz crystal impedance system; FT-IR;
D O I
10.1021/jf052489r
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Combined measurements of piezoelectric quartz crystal impedance (PQCI) and electrochemical impedance (EI) were utilized in situ to monitor the adsorption of bovine serum albumin (BSA) onto the newly prepared Au colloid- modified electrode and study the binding process of tannic acid (TA) to BSA on the BSA- modified electrode surface. The time courses of the resonant frequency and the equivalent parameters of the sensor were simultaneously obtained during BSA adsorption and TA-BSA binding. Compared with the bare gold electrode, the Au colloid- modified gold electrode showed better biocompatibility, and the absorption capacity for BSA was increased by similar to 2.4 times. The observed frequency decrease was ascribed to the mass increase of the sensor surface resulting from the TA-BSA binding, which is believed to result mainly from the hydrogen bonding from FT-IR characterization. The maximal molar binding ratio of TA binding to immobilized BSA obtained from the frequency shift of the adsorbed BSA and TA was estimated to be 10.3:1. On the basis of the frequency decrease with time, the kinetics of the binding was quantitatively studied. By way of fitting the experimental data, the kinetics parameters, that is, binding and dissociation constant (k(1), k(-1)), and the binding equilibrium constant (k(a)) were determined, giving values of 9.51 x 10(4) M-1 s(-1), 3.15 s(-1), and 3.1 x 10(4) M-1, respectively.
引用
收藏
页码:4087 / 4094
页数:8
相关论文
共 21 条
  • [1] Monitoring of the interaction of tannin with bovine serum albumin by electrochemical quartz-crystal impedance system and fluorescence spectrophotometry
    Zhang, YY
    Wang, ML
    Xie, QJ
    Wen, XH
    Yao, SZ
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 105 (02): : 454 - 463
  • [2] Monitoring for adsorption of human serum albumin and bovine serum albumin onto bare and polystyrene-modified silver electrodes by quartz crystal impedance analysis
    Mao, YA
    Wei, WZ
    Peng, H
    Zhang, JZ
    JOURNAL OF BIOTECHNOLOGY, 2001, 89 (01) : 1 - 10
  • [3] Effect of bovine serum albumin on gallic acid and tannic acid radical scavenging properties and binding kinetics with 2,2-diphenyl-1-picrylhydrazyl
    Grigoryan, Karine
    Shilajyan, Hasmik
    Savvaidis, Ioannis
    Mkhitaryan, Liana
    Zatikyan, Ashkhen
    PROCESS BIOCHEMISTRY, 2024, 141 : 30 - 38
  • [4] In situ monitoring of gold-surface adsorption and acidic denaturation of human serum albumin by an isolation-capacitance-adopted electrochemical quartz crystal impedance system
    Xie, QJ
    Xiang, CH
    Zhang, YY
    Yuan, Y
    Liu, MM
    Nie, LH
    Yao, SZ
    ANALYTICA CHIMICA ACTA, 2002, 464 (01) : 65 - 77
  • [5] Combined quartz crystal impedance and electrochemical impedance measurements during adsorption of bovine serum albumin onto bare and cysteine- or thiophenol-modified gold electrodes
    Xie, QJ
    Zhang, YY
    Xu, MC
    Li, ZL
    Yuan, Y
    Yao, SZ
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 478 (1-2): : 1 - 8
  • [6] Immobilization of bovine serum albumin as a sensitive biosensor for the detection of trace lead ion in solution by piezoelectric quartz crystal impedance
    Yin, Jian
    Wei, Wanzhi
    Liu, Xiaoying
    Kong, Bo
    Wu, Ling
    Gong, Shuguo
    ANALYTICAL BIOCHEMISTRY, 2007, 360 (01) : 99 - 104
  • [7] The detection of bovine serum albumin by using Cu2+ based on a piezoelectric quartz crystal impedance technique
    Cai, Y
    Yin, F
    Xie, QJ
    Zhang, YY
    Yao, SZ
    MICROCHEMICAL JOURNAL, 2001, 68 (01) : 71 - 76
  • [8] Real-time investigation of the interaction between primaquine phosphate and bovine serum albumin (BSA) by piezoelectric quartz crystal impedance analysis
    Long, YM
    Chen, JH
    Zhang, ZH
    Yao, SZ
    JOURNAL OF BIOTECHNOLOGY, 2003, 105 (1-2) : 105 - 116
  • [9] A piezoelectric quartz crystal impedance study on Cu2+-induced precipitation of bovine serum albumin in aqueous solution
    Cai, Y
    Xie, QJ
    Zhou, AH
    Zhang, YY
    Yao, SZ
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2001, 47 (03): : 209 - 219
  • [10] Evaluation the binding of chlorogenic acid with bovine serum albumin: Spectroscopic methods, electrochemical and molecular docking
    Jia, Wenchao
    Jin, Xiangying
    Liu, Wang
    Zhao, Bo
    Zhang, Manwen
    Yang, Yanyan
    Yin, Wenhua
    Zhang, Yukui
    Liu, Yanyan
    Zhou, Sangyang
    Qin, Dilan
    Xie, Danping
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 291