Analysis of some pesticides in water samples using solid-phase microextraction-gas chromatography with different mass spectrometric techniques

被引:69
作者
Natangelo, M [1 ]
Tavazzi, S [1 ]
Fanelli, R [1 ]
Benfenati, E [1 ]
机构
[1] Ist Ric Farmacol Mario Negri, Dept Environm Hlth, I-20157 Milan, Italy
关键词
water analysis; environmental analysis; pesticides;
D O I
10.1016/S0021-9673(99)00850-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A solid-phase microextraction (SPME)-GC procedure has been developed for the analysis of four selected pesticides (propanil, acetochlor, myclobutanil and fenoxycarb) in water samples. Mass spectrometry (MS) was used and two different instruments, a quadrupole MS system and an ion trap operating in the MS-MS mode, were compared. A Carbowax-divinylbenzene SPME fiber was used. The performances of the two GC-MS instruments were comparable in terms of linearity (in the range of 0.1-10 mu g/l in water samples) and sensitivity (limits of detection were in the low ng/l range); the quadrupole MS instrument gave better precision than the ion trap MS-MS system, but generally the relative standard deviations for replicates were acceptable for both instruments (<15%). Specificity with these two instruments was comparable in the analysis of ground water samples. Recovery tests were made to assess the applicability of the SPME procedure in the quantitative analysis of contaminated groundwaters. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:193 / 201
页数:9
相关论文
共 26 条
  • [1] Solid-phase microextraction and gas chromatography with mass spectrometric detection for the determination of pesticides in aqueous samples
    Aguilar, C
    Peñalver, S
    Pocurull, E
    Borrull, F
    Marcé, RM
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 795 (01) : 105 - 115
  • [2] EXTENSION OF THE BIOAUTOGRAPH TECHNIQUE FOR MULTIRESIDUE DETERMINATION OF FUNGICIDE RESIDUES IN PLANTS AND WATER
    BALINOVA, A
    [J]. ANALYTICA CHIMICA ACTA, 1995, 311 (03) : 423 - 427
  • [3] ENVIRONMENTAL-PROTECTION-AGENCY AND OTHER METHODS FOR THE DETERMINATION OF PRIORITY PESTICIDES AND THEIR TRANSFORMATION PRODUCTS IN WATER
    BARCELO, D
    [J]. JOURNAL OF CHROMATOGRAPHY, 1993, 643 (1-2): : 117 - 143
  • [5] AUTOMATED-DETERMINATION OF S-TRIAZINE HERBICIDES USING SOLID-PHASE MICROEXTRACTION
    BARNABAS, IJ
    DEAN, JR
    FOWLIS, IA
    OWEN, SP
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (02) : 305 - 312
  • [6] Solid-phase microextraction for quantitative analysis of organophosphorus pesticides in environmental water samples
    Beltran, J
    Lopez, FJ
    Cepria, O
    Hernandez, F
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 808 (1-2) : 257 - 263
  • [7] SIMULTANEOUS ANALYSIS OF 50 PESTICIDES IN WATER SAMPLES BY SOLID-PHASE EXTRACTION AND GC-MS
    BENFENATI, E
    TREMOLADA, P
    CHIAPPETTA, L
    FRASSANITO, R
    BASSI, G
    DITORO, N
    FANELLI, R
    STELLA, G
    [J]. CHEMOSPHERE, 1990, 21 (12) : 1411 - 1421
  • [8] Bennett DA, 1997, J AOAC INT, V80, P1065
  • [9] Simultaneous determination of 60 pesticides in water using solid-phase microextraction and gas chromatography mass spectrometry
    BoydBoland, AA
    Magdic, S
    Pawliszyn, JB
    [J]. ANALYST, 1996, 121 (07) : 929 - 937
  • [10] SOLID-PHASE MICROEXTRACTION OF NITROGEN-CONTAINING HERBICIDES
    BOYDBOLAND, AA
    PAWLISZYN, JB
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 704 (01) : 163 - 172