Complications of transvaginal monofilament polypropylene mesh in pelvic organ prolapse repair

被引:59
作者
Ganj, Farnaz A. [1 ]
Ibeanu, Okechukwu A. [1 ]
Bedestani, Ahmet [1 ]
Nolan, Thomas E. [1 ]
Chesson, Ralph R. [1 ]
机构
[1] Louisiana State Univ, Dept Obstet & Gynecol, Hlth Sci Ctr, New Orleans, LA 70112 USA
关键词
Polypropylene mesh; Pelvic organ prolapse (POP); ANTERIOR COMPARTMENT PROLAPSE; VAGINAL PROLAPSE; SURGERY; FLOOR; EROSION;
D O I
10.1007/s00192-009-0879-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
This study aimed to document intraoperative and postoperative complications associated with the use of transvaginal polypropylene mesh in the repair of pelvic organ prolapse (POP). This is a retrospective review of 127 cases of transvaginal repair of POP using synthetic mesh. Mean postoperative value (+/- SD) for pelvic organ prolapse quantification (POPQ) measurements Aa, Ap, and C were: -2.4 +/- 1.1 (cm), -2.4 +/- 0.9 (cm), and -7.7 +/- 1.2 (cm), respectively. The difference between preoperative and postoperative values of these points was significant (p < 0.0001). Mesh erosion rate was 13/127 (10.2%) with significant correlation between mesh erosion and concurrent vaginal hysterectomy (p = 0.008). Combined anterior and posterior vaginal mesh surgery increased the risk of intraoperative bleeding and blood transfusion (p < 0.05). Concurrent vaginal hysterectomy is associated with increased risk of vaginal mesh erosion. Combined anterior and posterior vaginal mesh repair is an increased risk factor for intraoperative bleeding and blood transfusion.
引用
收藏
页码:919 / 925
页数:7
相关论文
共 20 条
[1]   Perioperative morbidity using transvaginal mesh in pelvic organ prolapse repair [J].
Altman, Daniel ;
Falconer, Christian .
OBSTETRICS AND GYNECOLOGY, 2007, 109 (02) :303-308
[2]  
[Anonymous], [No title captured]
[3]   Risk evaluation of smoking and age on the occurrence of postoperative erosions after transvaginal mesh repair for pelvic organ prolapses [J].
Araco, Francesco ;
Gravante, Gianpiero ;
Sorge, Roberto ;
De Vita, Davide ;
Piccione, Emilio .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2008, 19 (04) :473-479
[4]   Intraligamentous nerves as a potential source of pain after sacrospinous ligament fixation of the vaginal apex [J].
Barksdale P.A. ;
Gasser R.F. ;
Gauthier C.M. ;
Elkins T.E. ;
Wall L.L. .
International Urogynecology Journal, 1997, 8 (3) :121-125
[5]   The role of synthetic and biological prostheses in reconstructive pelvic floor surgery [J].
Birch, C ;
Fynes, MM .
CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2002, 14 (05) :527-535
[6]   Dyspareunia and mesh erosion after vaginal mesh placement with a kit procedure [J].
Boyles, Sarah Hamilton ;
McCrery, Rebecca .
OBSTETRICS AND GYNECOLOGY, 2008, 111 (04) :969-975
[7]   The standardization of terminology of female pelvic organ prolapse and pelvic floor dysfunction [J].
Bump, RC ;
Mattiasson, A ;
Bo, K ;
Brubaker, LP ;
DeLancey, JOL ;
Klarskov, P ;
Shull, BL ;
Smith, ARB .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1996, 175 (01) :10-17
[8]   Vaginal mesh erosion after transvaginal repair of cystocele using Gynemesh or Gynemesh-Soft in 138 women: a comparative study [J].
Deffieux, X. ;
de Tayrac, R. ;
Huel, C. ;
Bottero, J. ;
Gervaise, A. ;
Bonnet, K. ;
Frydman, R. ;
Fernandez, H. .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2007, 18 (01) :73-79
[9]   Retroperitoneal hemorrhage after a vaginal mesh prolapse procedure [J].
Gangam, Nirupa ;
Kanee, Allan .
OBSTETRICS AND GYNECOLOGY, 2007, 110 (02) :463-464
[10]   Follow-up after polypropylene mesh repair of anterior and posterior compartments in patients with recurrent prolapse [J].
Gauruder-Burmester, A. ;
Koutouzidou, P. ;
Rohne, J. ;
Gronewold, M. ;
Tunn, R. .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2007, 18 (09) :1059-1064