Accurate estimation of transduction efficiency necessitates a multiplex real-time PCR

被引:61
|
作者
Klein, D
Bugl, B
Günzburg, WH
Salmons, B
机构
[1] Univ Vet Sci, Inst Virol, A-1210 Vienna, Austria
[2] Bavarian Nord Res Inst GmbH, Martinsried, Germany
关键词
real-time PCR; retroviral vector; transduction efficiency; TaqMan; gene therapy;
D O I
10.1038/sj.gt.3301112
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Transduction efficiency can be easily monitored during preclinical trials by inclusion of marker genes. However, the use of such marker genes should be avoided in the final clinical gene therapy application since their products are often immunogenic, making it difficult to monitor transduction, especially if the vector is applied in vivo. In these cases PCR-based methods like the real-time PGR might provide a powerful tool to estimate biodistribution. To investigate the accuracy of this method, we have developed and tested a real-time PCR assay for the quantification of the enhanced green fluorescent protein (EGFP) gene and compared the results with transduction efficiencies estimated by FACS analysis. Although our real-time PCR assay itself was characterized by a high precision over a wide dynamic range of quantification, significant differences in the transduction efficiency compared with FACS data were initially observed Accurate determination could only be achieved using an optimized multiplex real-time PCR assay, which allows the simultaneous calculation of cell number and EGFP copy number in the same tube. In view of future needs for methods allowing precise and accurate analysis of biodistribution in gene therapy trials, our data highlight the necessity critically to check both parameters in the implemented assay.
引用
收藏
页码:458 / 463
页数:6
相关论文
共 50 条
  • [1] Accurate estimation of transduction efficiency necessitates a multiplex real-time PCR
    D Klein
    B Bugl
    W H Günzburg
    B Salmons
    Gene Therapy, 2000, 7 : 458 - 463
  • [2] Real-time multiplex PCR assays
    Wittwer, CT
    Herrmann, MG
    Gundry, CN
    Elenitoba-Johnson, KSJ
    METHODS, 2001, 25 (04) : 430 - 442
  • [3] Real-time PCR: An effective tool for measuring transduction efficiency in hematopoietic progenitor cells
    Villella, AD
    Yao, J
    Getty, RR
    Cornetta, K
    Williams, DA
    Pollok, KE
    MOLECULAR THERAPY, 2003, 7 (05) : S180 - S180
  • [4] Multiplex real-time PCR detection of Vibrio cholerae
    Gubala, Aneta J.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2006, 65 (02) : 278 - 293
  • [5] Multiplex real-time PCR assay for Legionella species
    Kim, Seung Min
    Jeong, Yoojung
    Sohn, Jang Wook
    Kim, Min Ja
    MOLECULAR AND CELLULAR PROBES, 2015, 29 (06) : 414 - 419
  • [6] Real-time multiplex PCR for the diagnosis of syphilis and chancroid
    Alexander, S
    Cole, M
    Martin, I
    Gundugola, K
    Bignell, CJ
    Ison, C
    SEXUALLY TRANSMITTED INFECTIONS, 2006, 82 : A2 - A3
  • [7] Multiplex real-time PCR for dermatophytes detection and identification
    Arabatzis, M.
    van Coppenraet, L. Bruijnesteijn
    Kuijper, E.
    de Hoog, S.
    Lavrijsen, A.
    Templeton, K.
    van der Raaij-Helmer, E.
    Velegraki, A.
    Summerbell, R.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2006, 126 : 128 - 128
  • [8] Real-Time Multiplex PCR Analysis in Infectious Uveitis
    Minkus, Caroline L.
    Bispo, Paulo J. M.
    Papaliodis, George N.
    Sobrin, Lucia
    SEMINARS IN OPHTHALMOLOGY, 2019, 34 (04) : 252 - 255
  • [9] Standardisation and validation of multiplex real-time PCR systems
    Hoffmann, B.
    Depner, K.
    Beer, M.
    New Diagnostic Technology: Applications in Animal Health and Biologics Controls, 2006, 126 : 53 - 54
  • [10] High-multiplex real-time PCR design
    Agee, Sara