Prevalence of non-cardiac findings in a large series of patients undergoing cardiac multi-detector computed tomography scans

被引:16
作者
Chia, Pow-Li [1 ]
Kaw, Gregory [2 ]
Wansaicheong, Gervais [2 ]
Ho, Kheng-Thye [1 ]
机构
[1] Tan Tock Seng Hosp, Dept Cardiol, Singapore 308433, Singapore
[2] Tan Tock Seng Hosp, Dept Diagnost Radiol, Singapore 308433, Singapore
关键词
Cardiac multi-detector computed tomography; Non-cardiac findings; Cardiac imaging; Computed tomography; CORONARY-ARTERY CALCIFICATION; EXTRACARDIAC FINDINGS; HEPATITIS-B; ANGIOGRAPHY; CALCIUM; CT; STENOSES; QUANTIFICATION; ULTRASOUND; ACCURACY;
D O I
10.1007/s10554-009-9455-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of our study was to determine the prevalence of non-cardiac findings in a large series of patients undergoing contrast-enhanced cardiac multi-detector computed tomography (MDCT) scans. Non-cardiac findings were classified according to the organ of involvement and level of significance. We retrospectively reviewed scans and reports of 1,061 patients performed between 1 April 2004 and 31 April 2006. Non-cardiac findings were considered significant if they warranted further radiological or clinical follow-up. A total of 103 non-cardiac findings were reported in 85 (8.0%) of the 1,061 patients. Of these lesions, 48 (46.7%) were significant and 55 (53.3%) were not. The significant lesions were found in 33 of the 1,061 patients (3.1%). Among the significant abnormalities, the three most common were pulmonary nodules (16.7%), emphysema (16.7%) and possible hepatic carcinomas (12.6%). Patients with non-cardiac findings were significantly older than those without (mean age 60 +/- A 6 years vs. 55 +/- A 8 years; P < 0.0001). The prevalence of active smoking was significantly higher in patients with non-cardiac findings (28.2 vs. 17.8%; P = 0.03). The prevalence of non-cardiac abnormalities detected by cardiac MDCT was 8% and about half of these findings were deemed significant. These lesions commonly occurred in the lungs and the liver. Age and active smoking were predictive of the presence of non-cardiac abnormalities.
引用
收藏
页码:537 / 543
页数:7
相关论文
共 27 条
[1]   Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation [J].
Achenbach, S ;
Ropers, D ;
Pohle, FK ;
Raaz, D ;
von Erffa, J ;
Yilmaz, A ;
Muschiol, G ;
Daniel, WG .
EUROPEAN HEART JOURNAL, 2005, 26 (19) :1978-1986
[2]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[3]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[4]   THE CHANGING EPIDEMIOLOGY OF HEPATITIS-B IN THE UNITED-STATES - NEED FOR ALTERNATIVE VACCINATION STRATEGIES [J].
ALTER, MJ ;
HADLER, SC ;
MARGOLIS, HS ;
ALEXANDER, WJ ;
HU, PY ;
JUDSON, FN ;
MARES, A ;
MILLER, JK ;
MOYER, LA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1990, 263 (09) :1218-1222
[5]   Prediction of coronary events with electron beam computed tomography [J].
Arad, Y ;
Spadaro, LA ;
Goodman, K ;
Newstein, D ;
Guerci, AD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) :1253-1260
[6]  
BACHAR NG, 2007, J COMPUT ASSIST TOMO, V31, P1
[7]   Comparison of electron beam computed tomography with intracoronary ultrasound and coronary angiography for detection of coronary atherosclerosis [J].
Baumgart, D ;
Schmermund, A ;
Goerge, G ;
Haude, M ;
Ge, JB ;
Adamzik, M ;
Sehnert, C ;
Altmaier, K ;
Groenemeyer, D ;
Seibel, R ;
Erbel, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (01) :57-64
[8]   Helical and single-slice conventional CT versus electron beam CT for the quantification of coronary artery calcification [J].
Becker, CR ;
Jakobs, TF ;
Aydemir, S ;
Becker, A ;
Knez, A ;
Schoepf, UJ ;
Bruening, R ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :543-547
[9]   Coronary artery calcium measurement: Agreement of multirow detector and electron beam CP [J].
Becker, CR ;
Kleffel, T ;
Crispin, A ;
Knez, A ;
Young, J ;
Schoepf, UJ ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1295-1298
[10]   Frequency and severity of "incidentalomas" encountered during electron beam computed tomography for coronary calcium in middle-aged army personnel [J].
Elgin, EE ;
O'Malley, PG ;
Feuerstein, I ;
Taylor, AJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (05) :543-+