Optimization of an Optical Inspection System Based on the Taguchi Method for Quantitative Analysis of Point-of-Care Testing

被引:12
作者
Yeh, Chia-Hsien [1 ]
Zhao, Zi-Qi [1 ]
Shen, Pi-Lan [2 ]
Lin, Yu-Cheng [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 701, Taiwan
[2] Firstep Biores Inc, Tainan 701, Taiwan
关键词
optical inspection system; Taguchi method; detection limit; linearity; PARAMETERS; PINHOLES; PROTEIN; DESIGN; ASSAY;
D O I
10.3390/s140916148
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study presents an optical inspection system for detecting a commercial point-of-care testing product and a new detection model covering from qualitative to quantitative analysis. Human chorionic gonadotropin (hCG) strips (cut-off value of the hCG commercial product is 25 mIU/mL) were the detection target in our study. We used a complementary metal-oxide semiconductor (CMOS) sensor to detect the colors of the test line and control line in the specific strips and to reduce the observation errors by the naked eye. To achieve better linearity between the grayscale and the concentration, and to decrease the standard deviation (increase the signal to noise ratio, S/N), the Taguchi method was used to find the optimal parameters for the optical inspection system. The pregnancy test used the principles of the lateral flow immunoassay, and the colors of the test and control line were caused by the gold nanoparticles. Because of the sandwich immunoassay model, the color of the gold nanoparticles in the test line was darkened by increasing the hCG concentration. As the results reveal, the S/N increased from 43.48 dB to 53.38 dB, and the hCG concentration detection increased from 6.25 to 50 mIU/mL with a standard deviation of less than 10%. With the optimal parameters to decrease the detection limit and to increase the linearity determined by the Taguchi method, the optical inspection system can be applied to various commercial rapid tests for the detection of ketamine, troponin I, and fatty acid binding protein (FABP).
引用
收藏
页码:16148 / 16158
页数:11
相关论文
共 50 条
  • [41] A miniaturised image based fluorescence detection system for point-of-care-testing of cocaine abuse
    Walczak, Rafal
    Krueger, Jan
    Moynihan, Shane
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (08)
  • [42] Validation of an electrochemical sensor based on gold nanoparticles as a point-of-care test for quantitative determination of glycated hemoglobin
    Boonprasert, Kanyarat
    Tharavanij, Thipaporn
    Pechyen, Chiravoot
    Ponsanti, Khanittha
    Tangnorawich, Benchamaporn
    Viyanant, Vithoon
    Na-Bangchang, Kesara
    [J]. PLOS ONE, 2023, 18 (06):
  • [43] Portable and multiplexed lateral flow immunoassay reader based on SERS for highly sensitive point-of-care testing
    Xiao, Rui
    Lu, Luchun
    Rong, Zhen
    Wang, Chongwen
    Peng, Yongjin
    Wang, Feng
    Wang, Jinhai
    Sun, Meijie
    Dong, Jian
    Wang, Dongfeng
    Wang, Luanluan
    Sun, Nanxi
    Wang, Shengqi
    [J]. BIOSENSORS & BIOELECTRONICS, 2020, 168
  • [44] Total internal reflection (TIRF)-based quantification of procalcitonin for sepsis diagnosis - A point-of-care testing application
    Rascher, Daniela
    Geerlof, Arie
    Kremmer, Elisabeth
    Kraemer, Petra
    Michael, Schmid
    Hartmann, Anton
    Rieger, Martin
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 59 : 251 - 258
  • [45] Development and applications of paper-based point-of-care testing platforms for electrochemical blood glucose detection
    Wang, Qi
    Feng, Yinan
    [J]. SENSOR REVIEW, 2025,
  • [46] A New Rapid Method for Clostridium difficile DNA Extraction and Detection in Stool Toward Point-of-Care Diagnostic Testing
    Freifeld, Alison G.
    Simonsen, Kari A.
    Booth, Christine S.
    Zhao, Xing
    Whitney, Scott E.
    Karre, Teresa
    Iwen, Peter C.
    Viljoen, Hendrik J.
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2012, 14 (03) : 274 - 279
  • [47] Optimization of green sand mould system using Taguchi based grey relational analysis
    Pulivarti, Srinivasa Rao
    Birru, Anil Kumar
    [J]. CHINA FOUNDRY, 2018, 15 (02) : 152 - 159
  • [48] TOPSIS BASED TAGUCHI METHOD FOR MULTI-RESPONSE SIMULATION OPTIMIZATION OF FLEXIBLE MANUFACTURING SYSTEM
    Ic, Yusuf Tansel
    Dengiz, Berna
    Dengiz, Orhan
    Cizmeci, Gozde
    [J]. PROCEEDINGS OF THE 2014 WINTER SIMULATION CONFERENCE (WSC), 2014, : 2147 - 2155
  • [49] Smartphone-Based Point-of-Care System Using Continuous-Wave Portable Doppler
    Jana, Biswabandhu
    Biswas, Rakesh
    Nath, Pallab Kumar
    Saha, Goutam
    Banerjee, Swapna
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (10) : 8352 - 8361
  • [50] Saliva-based creatine kinase MB measurement as a potential point-of-care testing for detection of myocardial infarction
    Mirzaii-Dizgah, Iraj
    Hejazi, Seyed Fakhreddin
    Riahi, Esmail
    Salehi, Mohammad Mohsen
    [J]. CLINICAL ORAL INVESTIGATIONS, 2012, 16 (03) : 775 - 779