Optimization of an Optical Inspection System Based on the Taguchi Method for Quantitative Analysis of Point-of-Care Testing

被引:12
|
作者
Yeh, Chia-Hsien [1 ]
Zhao, Zi-Qi [1 ]
Shen, Pi-Lan [2 ]
Lin, Yu-Cheng [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 701, Taiwan
[2] Firstep Biores Inc, Tainan 701, Taiwan
关键词
optical inspection system; Taguchi method; detection limit; linearity; PARAMETERS; PINHOLES; PROTEIN; DESIGN; ASSAY;
D O I
10.3390/s140916148
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study presents an optical inspection system for detecting a commercial point-of-care testing product and a new detection model covering from qualitative to quantitative analysis. Human chorionic gonadotropin (hCG) strips (cut-off value of the hCG commercial product is 25 mIU/mL) were the detection target in our study. We used a complementary metal-oxide semiconductor (CMOS) sensor to detect the colors of the test line and control line in the specific strips and to reduce the observation errors by the naked eye. To achieve better linearity between the grayscale and the concentration, and to decrease the standard deviation (increase the signal to noise ratio, S/N), the Taguchi method was used to find the optimal parameters for the optical inspection system. The pregnancy test used the principles of the lateral flow immunoassay, and the colors of the test and control line were caused by the gold nanoparticles. Because of the sandwich immunoassay model, the color of the gold nanoparticles in the test line was darkened by increasing the hCG concentration. As the results reveal, the S/N increased from 43.48 dB to 53.38 dB, and the hCG concentration detection increased from 6.25 to 50 mIU/mL with a standard deviation of less than 10%. With the optimal parameters to decrease the detection limit and to increase the linearity determined by the Taguchi method, the optical inspection system can be applied to various commercial rapid tests for the detection of ketamine, troponin I, and fatty acid binding protein (FABP).
引用
收藏
页码:16148 / 16158
页数:11
相关论文
共 50 条
  • [21] Optimization of testing parameters on the wear behaviour of metal matrix composites based on the Taguchi method
    Sahin, Y
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2005, 408 (1-2): : 1 - 8
  • [22] Point-of-care testing for D-dimer in the exclusion of venous thromboembolism: a critical analysis
    Grand, Francois
    Blanc-Jouvan, Florence
    Delassasseigne, Celine
    Galinat, Hubert
    Roy, Pierre-Marie
    Talon, Laurie
    Toussaint-Hacquard, Marie
    Macchi, Laurent
    ANNALES DE BIOLOGIE CLINIQUE, 2023, 81 (05) : 461 - 474
  • [23] Point-of-care testing for streptomycin based on aptamer recognizing and digital image colorimetry by smartphone
    Lin, Bixia
    Yu, Ying
    Cao, Yujuan
    Guo, Manli
    Zhu, Debin
    Dai, Jiaxing
    Zheng, Minshi
    BIOSENSORS & BIOELECTRONICS, 2018, 100 : 482 - 489
  • [24] A dry chemistry-based electrochemiluminescence device for point-of-care testing of alanine transaminase
    Lai, Wei
    Shi, Yanyang
    Zhong, Jinbiao
    Zhou, Xinya
    Yang, Yang
    Chen, Zhenyu
    Zhang, Chunsun
    TALANTA, 2023, 256
  • [25] Analysis and optimization of a high-speed generator's cooling structure based on Taguchi method
    Tang, Chenqi
    Yu, Zhongjun
    Fu, Jia
    Yang, Juntan
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 63
  • [26] A Shake&Read distance-based microfluidic chip as a portable quantitative readout device for highly sensitive point-of-care testing
    Xie, Yi
    Wei, Xiaofeng
    Yang, Qizhen
    Guan, Zhichao
    Liu, Dan
    Liu, Xuan
    Zhou, Leiji
    Zhu, Zhi
    Lin, Zhenyu
    Yang, Chaoyong
    CHEMICAL COMMUNICATIONS, 2016, 52 (91) : 13377 - 13380
  • [27] Chitosan-modified nitrocellulose membrane for paper-based point-of-care testing
    Tang, Rui Hua
    Li, Min
    Liu, Li Na
    Zhang, Su Feng
    Alam, Nur
    You, Minli
    Ni, Yong Hao
    Li, Ze Dong
    CELLULOSE, 2020, 27 (07) : 3835 - 3846
  • [28] Quantitative assessment of disease markers using the naked eye: point-of-care testing with gas generation-based biosensor immunochromatographic strips
    Fu, Qiangqiang
    Wu, Ze
    Li, Jingxia
    Wu, Zengfeng
    Zhong, Hui
    Yang, Quanli
    Liu, Qihui
    Liu, Zonghua
    Sheng, Lianghe
    Xu, Meng
    Li, Tingting
    Yin, Zhinan
    Wu, Yangzhe
    JOURNAL OF NANOBIOTECHNOLOGY, 2019, 17 (1)
  • [29] DESIGN AND TESTING OF A SINGLE-ELEMENT ULTRASOUND VISCOELASTOGRAPHY SYSTEM FOR POINT-OF-CARE EDEMA QUANTIFICATION
    Pitre, John J., Jr.
    Koziol, Leo B.
    Kruger, Grant H.
    Vollmer, Alan
    Ophir, Jonathan
    Ammann, Jean-Jacques
    Weitzel, William F.
    Bull, Joseph L.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (09) : 2209 - 2219
  • [30] Parametric Optimization of Robot-based Single Point Incremental Forming Using Taguchi Method
    Ismail, Nazarul Abidin
    Ismail, Mohd Idris Shah
    Radzman, Mohamad Aizat Mohd
    Ariffin, Mohd Khairol Anuar Mohd
    As'arry, Azizan
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2019, 11 (01): : 217 - 224