Comprehensive Evaluation of Latest 2D/3D Monitors and Comparison to a Custom-Built 3D Mirror-Based Display in Laparoscopic Surgery

被引:0
作者
Wilhelm, Dirk [1 ,2 ]
Reiser, Silvano [2 ]
Kohn, Nils [1 ,2 ]
Witte, Michael [3 ]
Leiner, Ulrich [3 ]
Muehlbach, Lothar [3 ]
Ruschin, Detlef [3 ]
Reiner, Wolfgang [3 ]
Feussner, Hubertus [1 ,2 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, D-80290 Munich, Germany
[2] Tech Univ Munich, MITI working Grp minimally invas therapy & interv, Munich, Germany
[3] Fraunhofer Heinrich Hertz Inst, Berlin, Germany
来源
STEREOSCOPIC DISPLAYS AND APPLICATIONS XXV | 2014年 / 9011卷
关键词
Human Factors; Task Performance; Laparoscopy; 3D Gold Standard; 3D Display; 2D/3D Comparison; Medical Imaging; Autostereoscopy; SYSTEMS; VISION; PRECISION; 2-D;
D O I
10.1117/12.2040040
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Though theoretically superior, 3D video systems did not yet achieve a breakthrough in laparoscopic surgery. Furthermore, visual alterations, such as eye strain, diplopia and blur have been associated with the use of stereoscopic systems. Advancements in display and endoscope technology motivated a re-evaluation of such findings. A randomized study on 48 test subjects was conducted to investigate whether surgeons can benefit from using most current 3D visualization systems. Three different 3D systems, a glasses-based 3D monitor, an autostereoscopic display and a mirror-based theoretically ideal 3D display were compared to a state-of-the-art 2D HD system. The test subjects split into a novice and an expert surgeon group with high experience in laparoscopic procedures. Each of them had to perform a clearly defined laparoscopic suturing task. Multiple performance parameters like task completion time and stitching precision were measured and compared. Electromagnetic tracking provided information on the instrument's movement path length, velocity and economy. The NASA task load index was used to assess mental strain. Subjective ratings were added to assess usability, comfort and image quality of each display. Almost all performance parameters were superior for the 3D glasses-based display as compared to the 2D and the autostereoscopic one, but were often significantly exceeded by the mirror-based 3D display. Subjects performed the task on average 20% faster and with higher precision. Work-load parameters did not show significant differences. Experienced and non-experienced laparoscopists profited equally from 3D. The 3D mirror system gave clear evidence for additional potential of 3D visualization systems with higher resolution and motion parallax presentation.
引用
收藏
页数:14
相关论文
共 28 条
[1]   Evaluating motion and binocular parallax as depth cues for autostereoscopic displays [J].
Braun, Marius ;
Leiner, Ulrich ;
Ruschin, Detlef .
STEREOSCOPIC DISPLAYS AND APPLICATIONS XXII, 2011, 7863
[2]   Comparative study of 2-D and 3-D vision systems for minimally invasive surgery [J].
Buess, GF ;
vanBergen, P ;
Kunert, W ;
Schurr, MO .
CHIRURG, 1996, 67 (10) :1041-1046
[3]  
CARS, 2013, 27 INT C EXH COMP AS
[4]  
Cohen J., 1977, Statistical Power Analysis for the Behavioral Sciences
[5]   Visual integration of data and basic motor skills under laparoscopy - Influence of 2-D and 3-D video-camera systems [J].
Dion, YM ;
Gaillard, F .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (10) :995-1000
[6]   Influence of three-dimensional vision on surgical telemanipulator performance [J].
Falk, V ;
Mintz, D ;
Grünenfelder, J ;
Farm, JI ;
Burdon, TA .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 2001, 15 (11) :1282-1288
[7]  
Feng C, SURG ENDOSCOPY, V24, P2743
[8]  
Hofmeister J, 2001, Semin Laparosc Surg, V8, P12, DOI 10.1053/slas.2001.20835
[9]   The effects of different viewing conditions on performance in simulated minimal access surgery [J].
Huber, JW ;
Taffinder, N ;
Russell, RCG ;
Darzi, A .
ERGONOMICS, 2003, 46 (10) :999-1016
[10]   Stereoscopic vision provides a significant advantage for precision robotic laparoscopy [J].
Jourdan, IC ;
Dutson, E ;
Garcia, A ;
Vleugels, T ;
Leroy, J ;
Mutter, D ;
Marescaux, J .
BRITISH JOURNAL OF SURGERY, 2004, 91 (07) :879-885