Improved sample preparation and GC-MS analysis of priority organic pollutants

被引:5
作者
Polyakova, Olga V. [1 ]
Mazur, Dmitry M. [1 ]
Lebedev, Albert T. [1 ]
机构
[1] Moscow MV Lomonosov State Univ, Dept Chem, Moscow 119991, Russia
关键词
Priority pollutants; Gas chromatography/mass spectrometry; High-resolution mass spectrometry; Quantitative analysis; Express-analysis; Accelerated water sample preparation; LIQUID-LIQUID MICROEXTRACTION; CONTINUOUS-FLOW MICROEXTRACTION; GAS CHROMATOGRAPHY/MASS SPECTROMETRY; HEADSPACE SOLVENT MICROEXTRACTION; MASS-SPECTROMETRY; WATER SAMPLES; SINGLE DROP; PHASE MICROEXTRACTION; ENVIRONMENTAL-ANALYSIS; BACK-EXTRACTION;
D O I
10.1007/s10311-014-0464-4
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Mass spectrometry is a major tool for analysing organic pollutants. However, scientists often complain about laborious sample preparation. The development of new commercial high-resolution mass spectrometers gives a chance to improve simultaneously speed, reliability, and sensitivity of the analysis. Here, we used the time-of-flight high-resolution mass spectrometer Pegasus GC-HRT to identify and quantify 55 priority organic pollutants in water samples. This mass spectrometer has a high resolution of 50,000, a high mass accuracy of about 1 ppm and a very high acquisition rate of up to 200 full mass range spectra per second. 1 mL water samples were extracted with 1 mL dichloromethane. Results show that the sample preparation and analysis are achieved 30 times faster, requiring 1,000 times less water and 350 times less solvent than the classic 8270 method of the United States Environmental Protection Agency. The detection limit is 1 mu g/L. The quantification limit is 10 mu g/L. Our procedure, named accelerated water sample preparation, is simpler, faster, cheaper, safer and more reliable than 8270 Method.
引用
收藏
页码:419 / 427
页数:9
相关论文
共 37 条
[1]  
Alberici RM, 2012, COMPREHENSIVE ENV MA, P147
[2]   Modified solvent microextraction with back extraction combined with liquid chromatography-fluorescence detection for the determination of citalopram in human plasma [J].
Bagheri, Habib ;
Khalilian, Faezeh ;
Babanezhad, Esmaeil ;
Es-haghi, Ali ;
Rouini, Mohammad-Reza .
ANALYTICA CHIMICA ACTA, 2008, 610 (02) :211-216
[3]   Recent Advances in Environmental Analysis [J].
Ballesteros-Gomez, Ana ;
Rubio, Soledad .
ANALYTICAL CHEMISTRY, 2011, 83 (12) :4579-4613
[4]   Application of continuous-flow liquid phase microextraction to the analysis of phenolic compounds in wastewater samples [J].
Chen, Xinmiao ;
Zhang, Taozhi ;
Liang, Pei ;
Li, Yalan .
MICROCHIMICA ACTA, 2006, 155 (3-4) :415-420
[5]   Membrane-introduction mass spectrometry (MIMS) [J].
Davey, Nicholas G. ;
Krogh, Erik T. ;
Gill, Chris G. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (09) :1477-1485
[6]   Use of continuous-flow microextraction and liquid chromatography for determination of phoxim in water samples [J].
Guo, L ;
Liang, P ;
Zhang, TZ ;
Liu, Y ;
Liu, S .
CHROMATOGRAPHIA, 2005, 61 (9-10) :523-526
[7]   Ambient Sampling/Ionization Mass Spectrometry: Applications and Current Trends [J].
Harris, Glenn A. ;
Galhena, Asiri S. ;
Fernandez, Facundo M. .
ANALYTICAL CHEMISTRY, 2011, 83 (12) :4508-4538
[8]   Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640
[9]   Continuous flow microextraction combined with high-performance liquid chromatography for the analysis of pesticides in natural waters [J].
He, Yi ;
Lee, Hian Kee .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1122 (1-2) :7-12
[10]   Ambient ionization mass spectrometry: A tutorial [J].
Huang, Min-Zong ;
Cheng, Sy-Chi ;
Cho, Yi-Tzu ;
Shiea, Jentaie .
ANALYTICA CHIMICA ACTA, 2011, 702 (01) :1-15