Repeatability and Reproducibility Assessment of a PolyJet Technology Using X-ray Computed Tomography

被引:20
|
作者
Pilipovic, Ana [1 ]
Barsic, Gorana [1 ]
Katic, Marko [1 ]
Havstad, Maja Rujnic [1 ]
机构
[1] Univ Zagreb, Fac Mech Engn & Naval Architecture, Ivana Luc 5, Zagreb 10000, Croatia
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 20期
基金
欧盟地平线“2020”;
关键词
dimensional accuracy; PolyJet; repeatability; reproducibility; testing plate; X-ray computed tomography; DESIGN;
D O I
10.3390/app10207040
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Featured Application From the beginning of the use of additive technology in small series, a major problem has been the repeatability of the results. This repeatability is most evident in different dimensions of the finished product. Additionally, depending on the time of printing during the year, there are large differences in the same products. Such a problem is particularly apparent in the processes of additive production in which the material is applied in the liquid form. Such repeatability is, of course, a big problem for the industry which produces small series (e.g., designers). The results from this paper can be applied to processes in additive production that belong to the group of material jetting, but also to other processes where the input material is in the form of liquid, or where acrylates, epoxy resins, etc., are used. PolyJet consistently produces parts within +/- 100 mu m, at a 95% confidence interval. Accuracy and repeatability in the x and y axis are significantly better than in the z axis. Form errors (i.e., cylindricity) are larger than positional or dimensional errors. Holes with diameters less than 0.75 mm cannot be reliably produced using PolyJet. From the very start of their use until today, processes in Additive Manufacturing (AM) have found a way to grow from prototype production to individual and small-series production. Improvements in machinery, materials and other challenges in AM development have improved product quality, its mechanical properties and dimensional accuracy. Research in the field of dimensional accuracy must be focused on achieving better tolerances. From the beginning of AM, there has been a big issue in assuring dimensional repeatability and reproducibility of a part being printed over the course of several days. In order to examine that, a test plate was designed and built repeatedly with PolyJet technology over the course of several weeks. Measurements of dimensional accuracy and shape deviations of several typical features were carried out using X-ray Computed Tomography. Measurement results were analysed and presented in order to indicate the repeatability and reproducibility of PolyJet AM technology. Results show that PolyJet technology consistently produces parts within +/- 100 mu m, at a 95% confidence interval, under reproducibility conditions of over a 1-month period. Accuracy for measurands (distance) in the x and y axis was significantly better than it was for the z axis which was from 56 to 197 mu m, i.e., in the x and y axis, it was from -8 to 76 mu m. Shape errors (i.e., cylindricity) were larger than positional or dimensional errors; this can be attributed to relatively large surface roughness and small feature sizes on the test plate that was used.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [31] Traceable Porosity Measurements in Industrial Components Using X-Ray Computed Tomography
    Hermanek, Petr
    Zanini, Filippo
    Carmignato, Simone
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (05):
  • [32] Representative elementary volume analysis of sands using X-ray computed tomography
    Reza Razavi, Mohammad
    Muhunthan, Balasingam
    Al Hattamleh, Omar
    GEOTECHNICAL TESTING JOURNAL, 2007, 30 (03): : 212 - 219
  • [33] Density mapping of decaying wood using X-ray computed tomography.
    Herve, Vincent
    Mothe, Frederic
    Freyburger, Charline
    Gelhaye, Eric
    Frey-Klett, Pascale
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2014, 86 : 358 - 363
  • [34] Simple and fast porosity analysis of concrete using X-ray computed tomography
    du Plessis, Anton
    Olawuyi, Babatunde James
    Boshoff, William Peter
    le Roux, Stephan Gerhard
    MATERIALS AND STRUCTURES, 2016, 49 (1-2) : 553 - 562
  • [35] X-ray computed tomography for additive manufacturing: a review
    Thompson, A.
    Maskery, I.
    Leach, R. K.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (07)
  • [36] Simple and fast porosity analysis of concrete using X-ray computed tomography
    Anton du Plessis
    Babatunde James Olawuyi
    William Peter Boshoff
    Stephan Gerhard le Roux
    Materials and Structures, 2016, 49 : 553 - 562
  • [37] Characterizing Jetting in an Acoustic Fluidized Bed Using X-Ray Computed Tomography
    Escudero, David R.
    Heindel, Theodore J.
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (04):
  • [38] Assessment of the burrow system of Lumbricus terrestris, Aporrectodea giardi, and Aporrectodea caliginosa using X-ray computed tomography
    Jegou, D
    Cluzeau, D
    Wolf, HJ
    Gandon, Y
    Trehen, P
    BIOLOGY AND FERTILITY OF SOILS, 1998, 26 (02) : 116 - 121
  • [39] Assessment of the burrow system of Lumbricus terrestris, Aporrectodea giardi, and Aporrectodea caliginosa using X-ray computed tomography
    Jégou D.
    Cluzeau D.
    Wolf H.J.
    Gandon Y.
    Tréhen P.
    Biology and Fertility of Soils, 1997, 26 (2) : 116 - 121
  • [40] An Investigation of Hydrate Formation in Unsaturated Sediments Using X-Ray Computed Tomography
    Lei, Liang
    Liu, Zhichao
    Seol, Yongkoo
    Boswell, Ray
    Dai, Sheng
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2019, 124 (04) : 3335 - 3349