Determination of morphine, oripavine and pseudomorphine using capillary electrophoresis with acidic potassium permanganate chemiluminescence detection

被引:51
作者
Barnett, NW [1 ]
Hindson, BJ [1 ]
Lewis, SW [1 ]
机构
[1] Deakin Univ, Sch Biol & Chem Sci, Geelong, Vic 3217, Australia
关键词
D O I
10.1039/a906327g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and robust capillary electrophoresis chemiluminescence detection system for the determination of morphine, oripavine and pseudomorphine is described, based upon the reaction of these analytes with acidic potassium permanganate in the presence of sodium polyphosphate. The reagent solution was contained in a quartz detection cell which also held both the capillary and the anode. The resultant chemiluminescence was monitored directly using a photomultiplier tube mounted flush against the base of the detection cell. To ensure that no migration of the permanganate anion occurred, the anode was placed at the detector end whilst the electroosmotic flow was reversed by the addition of hexadimethrine bromide (0.001% m/v) to the electrolyte. The three analytes were separated counter to the electroosmotic flow via their interaction with alpha-cyclodextrin. The methodology realised detection limits (3 x S/N) of 2.5 x 10(-7) M for both morphine and oripavine and 5 x 10(-7) M for pseudomorphine. The relative standard deviations of the migration times and the peak heights for the three analytes ranged from 0.6 up to 0.8% and from 1.5 up to 2.1%, respectively.
引用
收藏
页码:91 / 95
页数:5
相关论文
共 50 条
[31]   SURFACE-CHARGE REVERSED CAPILLARY ZONE ELECTROPHORESIS OF INORGANIC AND ORGANIC-ANIONS [J].
OEFNER, PJ .
ELECTROPHORESIS, 1995, 16 (01) :46-56
[32]  
Regehr MF, 1996, J CAPILLARY ELECTROP, V3, P117
[33]   ACRIDINIUM CHEMILUMINESCENCE DETECTION WITH CAPILLARY ELECTROPHORESIS [J].
RUBERTO, MA ;
GRAYESKI, ML .
ANALYTICAL CHEMISTRY, 1992, 64 (22) :2758-2762
[34]   INVESTIGATION OF ACRIDINIUM LABELING FOR CHEMILUMINESCENCE DETECTION OF PEPTIDES SEPARATED BY CAPILLARY ELECTROPHORESIS [J].
RUBERTO, MA ;
GRAYESKI, ML .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1994, 6 (06) :545-550
[35]  
Shultz LL, 1998, J MICROCOLUMN SEP, V10, P329
[36]   FABRICATION AND EVALUATION OF POSTCAPILLARY JUNCTIONS VIA MICROSCALE MOLDING FOR USE AS REACTORS AND FLOW MULTIPLEXERS IN CAPILLARY ELECTROKINETIC SEPARATIONS [J].
STALLER, TD ;
SEPANIAK, MJ .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 1995, 23 (04) :235-254
[37]   Coelectroosmotic separations of anions in non-aqueous capillary electrophoresis [J].
Tjornelund, J ;
Bazzanella, A ;
Lochmann, H ;
Bächmann, K .
JOURNAL OF CHROMATOGRAPHY A, 1998, 811 (1-2) :211-217
[38]   Migration behavior of dyestuff-containing liposomes in capillary electrophoresis with chemiluminescence detection [J].
Tsukagoshi, K ;
Okumura, Y ;
Nakajima, R .
JOURNAL OF CHROMATOGRAPHY A, 1998, 813 (02) :402-407
[39]   Characterization of dyestuff-containing liposome by capillary zone electrophoresis using on-line chemiluminescence detection [J].
Tsukagoshi, K ;
Akasaka, H ;
Nakajima, R ;
Hara, T .
CHEMISTRY LETTERS, 1996, (06) :467-468
[40]   Electrophoretic behavior of dyestuff-containing liposome in a capillary with original on-line chemiluminescence detection [J].
Tsukagoshi, K ;
Okumura, Y ;
Akasaka, H ;
Nakajima, R ;
Hara, T .
ANALYTICAL SCIENCES, 1996, 12 (06) :869-874