Comparison of position, morphology and calcification of Coronary Plaque with 320-row dynamic volume CT (DVCT) and coronary angiography (CAG)

被引:0
|
作者
Li, Xiaoyan [1 ]
Zhang, Guoming [1 ]
Zhang, Hongming [1 ]
机构
[1] Gen Hosp Jinan Mil Reg, Dept Cardiol, Jinan 250031, Peoples R China
关键词
Calcification; Coronary angiography; Dynamic volume CT; Position; Plaque morphology; MULTISLICE COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; ARTERY CALCIUM; QUANTIFICATION; ACCURACY; DISEASE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The judgment of coronary stenosis by 320-row dynamic volume CT (DVCT) and coronary angiography (CAG) is not entirely consistent. We compared them in this study. Methods: We studied 92 patients (265 lesions) with CAG and DVCT. According to the degree of matching in stenosis judgment, all lesions were divided into consistent group and inconsistent group. The position of lesions, the degree of bending, plaque morphology, and calcification proportion were analyzed. Results: There were 236 lesions in consistent group and 29 lesions in inconsistent group. In inconsistent group, there were more LCX lesions, distal lesions, ostial lesions and tortuous lesions than those in consistent group (P < 0.05). At the same time, the proportion of nubbly type plaque, mixed plaque, nubbly and nodular type calcification in the main plaque in inconsistent group were higher than those in consistent group (P < 0.05). The lesions in inconsistent group showed higher calcification load, such as higher segmental coronary calcium score, more calcification points and higher calcification proportion than those in consistent group (P < 0.05). Conclusion: When coronary lesion is in ostial, distal or tortuous position, and when the main plaque is nubbly type or with heavy calcification load, the judgment of stenosis by DVCT and CAG is more apt to inconsistent.
引用
收藏
页码:824 / 829
页数:6
相关论文
共 50 条
  • [1] The effect of heart rate on coronary plaque measurements in 320-row coronary CT angiography
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Sakabe, Daisuke
    Oda, Seitaro
    Nakaura, Takeshi
    Yuki, Hideaki
    Nagayama, Yasunori
    Hirata, Kenichiro
    Iyama, Yuji
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (12) : 1977 - 1985
  • [2] Comparison of 320-Row Computed Tomography Coronary Angiography With Conventional Angiography for the Assessment of Coronary Artery Disease With Different Atherosclerotic Plaque Characteristics
    Yang, Qing-Hui
    Chen, Yan-Jun
    Liu, Qian-Qian
    Dong, Min
    Wen, Liang
    Song, Xiang
    Lv, Yan-Jie
    Gong, Ying-Zi
    Li, Xue-Qi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (06) : 646 - 653
  • [3] Subtracted Computed Tomography Angiography in the Evaluation of Coronary Arteries With Severe Calcification or Stents Using a 320-Row Computed Tomography Scanner
    Chen, Chun-Chi
    Wu, Patricia Wanping
    Tsay, Pei-Kwei
    Wang, Chun-Chieh
    Toh, Cheng-Hong
    Wan, Yung-Liang
    JOURNAL OF THORACIC IMAGING, 2020, 35 (05) : 317 - 325
  • [4] Evaluation of CT coronary artery angiography with 320-row detector CT in a high-risk population
    Gang, S.
    Min, L.
    Li, L.
    Guo-Ying, L.
    Lin, X.
    Qun, J.
    Hua, Z.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1013) : 562 - 570
  • [5] Clinical significance of transluminal attenuation gradient in 320-row area detector coronary CT angiography
    Kato, Etsuro
    Fujimoto, Shinichiro
    Takamura, Kazuhisa
    Kawaguchi, Yuko
    Aoshima, Chihiro
    Hiki, Makoto
    Kumamaru, Kanako K.
    Daida, Hiroyuki
    HEART AND VESSELS, 2018, 33 (05) : 462 - 469
  • [6] The usefulness of low radiation dose subtraction coronary computed tomography angiography for patients with calcification using 320-row area detector CT
    Takamura, Kazuhisa
    Fujimoto, Shinichiro
    Kawaguchi, Yuko
    Kato, Etsuro
    Aoshima, Chihiro
    Hiki, Makoto
    Kumamaru, Kanako K.
    Daida, Hiroyuki
    JOURNAL OF CARDIOLOGY, 2019, 73 (1-2) : 58 - 64
  • [7] Diagnostic performance of coronary angiography utilizing intraprocedural 320-row computed tomography with minimal contrast medium
    Chimura, Misato
    Ohtani, Tomohito
    Yokoi, Kensuke
    Shiraki, Tatsuya
    Katsimichas, Themistoklis
    Kitao, Takashi
    Awata, Masaki
    Mizote, Isamu
    Hikoso, Shungo
    Sumitsuji, Satoru
    Sakata, Yasushi
    HEART AND VESSELS, 2020, 35 (10) : 1341 - 1348
  • [8] Evaluation of the Effect of Intracoronary Attenuation on Coronary Plaque Measurements Using a Dual-phase Coronary CT Angiography Technique on a 320-row CT Scanner-In Vivo Validation Study
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Oda, Seitaro
    Funama, Yoshinori
    Nakaura, Takeshi
    Yuki, Hideaki
    Hirata, Kenichiro
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    ACADEMIC RADIOLOGY, 2016, 23 (03) : 315 - 320
  • [9] 320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose
    Chuanchen Zhang
    Zhaoqi Zhang
    Zixu Yan
    Lei Xu
    Wei Yu
    Rui Wang
    The International Journal of Cardiovascular Imaging, 2011, 27 : 1059 - 1068
  • [10] 320-row CT coronary angiography: effect of 100-kV tube voltages on image quality, contrast volume, and radiation dose
    Zhang, Chuanchen
    Zhang, Zhaoqi
    Yan, Zixu
    Xu, Lei
    Yu, Wei
    Wang, Rui
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) : 1059 - 1068