Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology

被引:29
|
作者
Borba, Marcia [1 ]
Miranda, Walter Gomes, Jr. [2 ]
Cesar, Paulo Francisco [2 ]
Griggs, Jason Allan [3 ]
Della Bona, Alvaro [1 ]
机构
[1] Univ Passo Fundo UPF, Sch Dent, Grad Program Dent, Passo Fundo, RS, Brazil
[2] Univ Sao Paulo, USP, Sch Dent, Dept Biomat & Oral Biochem, Sao Paulo, Brazil
[3] Univ Mississippi, Med Ctr, Sch Dent, Dept Biomed Mat Sci,UMMC, Jackson, MS 39216 USA
基金
美国国家卫生研究院; 巴西圣保罗研究基金会;
关键词
Computer-Aided Design; Denture; Partial; Fixed; Ceramics; DIFFERENT CAD/CAM SYSTEMS; LOAD-BEARING CAPACITY; ALL-CERAMIC CROWNS; FRACTURE-RESISTANCE; INTERNAL GAPS; CLINICAL FIT; RESTORATIONS; FRAMEWORKS; THICKNESS; STRENGTH;
D O I
10.1590/S1806-83242013000500003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs) (Y-TZP - LAVA, 3M-ESPE), using a novel methodology based on micro-computed tomography (micro-CT) technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm(2) connector cross-sections using a LAVA (TM) CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross-sectional images. Five measuring points were selected, as follows: MG - marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (alpha = 0.05). There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 mu m). OA had the highest median gap dimension (125 mu m), followed by the AOT point (105 mu m). CA and AW gap width values were statistically similar, 66 and 65 mu m respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations.
引用
收藏
页码:396 / 402
页数:7
相关论文
共 29 条
  • [1] Are Endodontically Treated Incisors Reliable Abutments for Zirconia-based Fixed Partial Dentures in the Esthetic Zone?
    Tunjan, Rene
    Rosentritt, Martin
    Sterzenbach, Guido
    Happe, Arndt
    Frankenberger, Roland
    Seemann, Rainer
    Naumann, Michael
    JOURNAL OF ENDODONTICS, 2012, 38 (04) : 519 - 522
  • [2] Zirconia ceramic fixed partial dentures after cyclic fatigue tests and clinical evaluation: a systematic review
    Gjurin, Sonja Zarkovic
    Oezcan, Mutlu
    Oblak, Cedomir
    ADVANCES IN APPLIED CERAMICS, 2019, 118 (1-2) : 62 - 69
  • [3] Zirconia-based dental crown to support a removable partial denture: a three-dimensional finite element analysis using contact elements and micro-CT data
    Rocha, Eduardo Passos
    Anchieta, Rodolfo Bruniera
    de Almeida, Erika Oliveira
    Freitas, Amilcar Chagas, Jr.
    Martini, Ana Paula
    Sotto-Maior, Bruno Sales
    Luersen, Marco Antonio
    Ko, Ching Chang
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (16) : 1744 - 1752
  • [4] Flexural strength of small connector designs of zirconia-based partial fixed dental prostheses
    Hamza, Tamer A.
    Attia, Mazen A.
    El-Hossary, Mohamed Mahmoud Khalil
    Mosleh, Ihab E.
    Shokry, Tamer E.
    Wee, Alvin G.
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (02) : 224 - 229
  • [5] Evaluation of the fit of zirconia three-unit fixed partial dentures fabricated by different impression techniques
    Moustapha, Ghassan
    Azzam, Khaled
    AlShwaimi, Emad
    Silwadi, Munir
    Ferraris, Marco
    Salameh, Ziad
    JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2019, 10 (03)
  • [6] A retrospective evaluation of zirconia-fixed partial dentures in general practices: An up to 13-year study
    Haff, Anna
    Lof, Hanna
    Gunne, Johan
    Sjogren, Goran
    DENTAL MATERIALS, 2015, 31 (02) : 162 - 170
  • [7] Prospective Evaluation of Zirconia Posterior Fixed Partial Dentures: 7-Year Clinical Results
    Rinke, Sven
    Gersdorff, Nikolaus
    Lange, Katharina
    Roediger, Matthias
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (02) : 164 - 171
  • [8] Prospective Evaluation of Zirconia Posterior Fixed Partial Dentures: Four-Year Clinical Results
    Roediger, Matthias
    Gersdorff, Nikolaus
    Huels, Alfons
    Rinke, Sven
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (02) : 141 - 148
  • [9] Biomechanical evaluation of 3-unit fixed partial dentures on monotype and two-piece zirconia dental implants
    Melo de Matos, Jefferson David
    Scalzer Lopes, Guilherme da Rocha
    Nomura Nakano, Leonardo Jiro
    Ramos, Nathalia de Carvalho
    Lucena de Vasconcelos, John Eversong
    Bottino, Marco Antonio
    Mendes Tribst, Joao Paulo
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (03) : 239 - 246
  • [10] Comparative Evaluation of the Dimensional Accuracy of Silicone-Based Putty Reline Impressions with Different Spacer Acquisition Techniques in Fixed Partial Dentures
    Sindi, Abdulelah Sameer
    Otudi, Hanan Salem A.
    Muslihi, Asma Ahmed A.
    Althurwi, Roaa Abdu
    Sayed, Mohammed E.
    Al-Makramani, Bandar M. A.
    Al-Sanabani, Fuad A.
    Ageel, Mohammad Abker Ahmed
    Jawbahi, Sultan A. Y.
    Kumar, Lakshya
    Hassan, Saeed Awod Bin
    Al Malwi, Ahmed Abdullah
    Kaleem, Sultan Mohammed
    Mattoo, Khurshid
    MEDICAL SCIENCE MONITOR, 2025, 31