New Method to Generate Observation Target for Contrast Sensitivity and Color Vision Inspection of the Human Eye

被引:0
作者
Zhang Jiyan [1 ]
Gao Mingliang [1 ]
Chen Yan [1 ]
Zhou Taogeng [2 ]
机构
[1] Natl Inst Metrol, Div Med & Biol Measurements, 18 Bei San Huan Dong Lu, Beijing 100013, Peoples R China
[2] Beijing Inst Technol, Opt Measurement Lab, Beijing 100081, Peoples R China
来源
PROCEEDINGS OF 2013 IEEE 11TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI) | 2013年
关键词
contrast; contrast sensitivity; color vision; integrating sphere; color mixing system; calibration;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Contrast sensitivity and color vision are two important aspects to evaluate the visual function of the human eye. The inspection is widely used in clinical ophthalmology, and of great significance for early diagnosis and identification of ophthalmic diseases. By analyzing the existing principles and shortcomings of the human eye contrast sensitivity and color difference inspection methods, a new method for generating observation target of contrast sensitivity and color vision inspection is proposed in this paper. By using double optical path design idea and integrating sphere and self-developed color mixing systems, two beams of uniform light with specific color and specific luminance can be produced. With subsequent reuse of the optical path, on one hand, accurate measurement of the human visual contrast and the color difference threshold value can be achieved, and on the other hand, measurement and calibration of contrast sensitivity tester and color tester widely used in clinical can be solved by developing assistant calibration transfer tools. Moreover, output parameters for contrast sensitivity and color difference can be precisely adjusted according to need and achieved real-time control and calibration with this method. The research has set the foundation for future establishment of visual threshold measuring device which is especially suitable for scientific and experimental research in clinical ophthalmology and metrology.
引用
收藏
页码:905 / 909
页数:5
相关论文
共 36 条
[31]   Human vision with a lesion of the parvocellular pathway: an optic neuritis model for selective contrast sensitivity deficits with severe loss of midget ganglion cell function [J].
Al-Hashmi, Amal M. ;
Kramer, Daniel J. ;
Mullen, Kathy T. .
EXPERIMENTAL BRAIN RESEARCH, 2011, 215 (3-4) :293-305
[32]   Visual Acuity, Contrast Sensitivity and Color Vision Three Years After Iodine-125 Brachytherapy for Choroidal and Ciliary Body Melanoma [J].
Tsui, Irena ;
Beardsley, Robert M. ;
McCannel, Tara A. ;
Oliver, Scott C. ;
Chun, Melissa W. ;
Lee, Steve P. ;
Chow, Phillip E. ;
Agazaryan, Nzhde ;
Yu, Fei ;
Straatsma, Bradley R. .
OPEN OPHTHALMOLOGY JOURNAL, 2015, 9 :131-135
[33]   Contrast Sensitivity Testing in Healthy and Blurred Vision Conditions Using a Novel Optokinetic Nystagmus Live-Detection Method [J].
Essig, Peter ;
Sauer, Yannick ;
Wahl, Siegfried .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (12)
[34]   A new maximum color contrast sensitivity test for detecting early changes of visual function in age-related macular degeneration [J].
Liutkeviciene, Rasa ;
Cebatoriene, Dzastina ;
Zaliuniene, Dalia ;
Lukauskiene, Rita ;
Jasinskas, Vytautas .
Medicina-Lithuania, 2014, 50 (05) :281-286
[35]   A new psychophysical method for determining the photopic spectral-luminosity function of the human eye [J].
Rovamo, J ;
Koljonen, T ;
Nasanen, R .
VISION RESEARCH, 1996, 36 (17) :2675-2680
[36]   New experimental diffractive-optical data on E.Land's Retinex mechanism in human color vision. (Part 1) - art. no. 638406 [J].
Lauinger, N. .