Wide Frequency Characterization of Intra-Body Communication for Leadless Pacemakers

被引:21
|
作者
Maldari, Mirko [1 ,2 ]
Albatat, Mohammad [3 ]
Bergsland, Jacob [3 ]
Haddab, Youcef [1 ]
Jabbour, Chadi [2 ]
Desgreys, Patricia [2 ]
机构
[1] Microport CRM, F-92140 Clamart, France
[2] Inst Polytech Paris, Telecom Paris, LTCI, F-91120 Palaiseau, France
[3] Oslo Univ Hosp, Rikshosp, Intervent Ctr, Oslo, Norway
基金
欧盟地平线“2020”;
关键词
Solid modeling; Electrodes; Pacemakers; Lead; Heart; Computational modeling; Probes; Intra-body communication; human body communication; leadless pacemaker; COMPLICATIONS; POPULATION; IMPEDANCE; COHORT; AREA;
D O I
10.1109/TBME.2020.2980205
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Leadless Cardiac Pacemakers (LCP) have the potential to revolutionize Cardiac Rhythm Management (CRM). Current LCPs can only pace a single location of the heart limiting their use to patients requiring singlechamber stimulation. A Multi-node system of synchronized LCPs could be used in a significantly larger patient population. Synchronization using standard communication techniques involves high power consumption decreasing the longevity of the device. In this work, we investigate Galvanic Intra Body Communication (IBC) as a method to synchronize multi-node LCP systems. First, an accurate computational torso model was used for quasi-static simulations to estimate channel pathloss in the frequency range [40 kHz-20 MHz]. The model was then verified with in-vivo measurements using a novel experimental setup, where two LCP devices were placed in the right atrium, right ventricle and left ventricle. All channels involved in a potential multi-node LCP system were characterized. The orientation of the transducers relative to each other had a great impact on the results, with the attenuation level ranging between 55 dB and 70 dB between the best and worst orientations. The best results were achieved in the MHz range. Coupled with the fact that it does not require additional electrodes, this study suggests Galvanic IBC be superior to conventional communication methods for LCP devices. This analysis defines a methodology for galvanic IBC channel characterization for LCP systems, which is an important step for the design of efficient transceivers for IBC applications. More experiments with larger datasets are needed to bring this method to practice.
引用
收藏
页码:3223 / 3233
页数:11
相关论文
共 50 条
  • [31] A Study on Intra-Body Communication for Personal Healthcare Monitoring System
    Alshehab, Abdullah
    Kobayash, Nao
    Kikuchi, Ryosuke
    Ruiz, Jordi
    Shimamoto, Shigeru
    Ishibashi, Hiroshi
    2008 10TH IEEE INTERNATIONAL CONFERENCE ON E-HEALTH NETWORKING, APPLICATIONS AND SERVICES, 2008, : 219 - +
  • [32] Signal Analysis for Touch Application Using Intra-Body Communication
    Kato, Ryota
    Toyoshima, Yutaro
    Nezu, Kenta
    Shinagawa, Mitsuru
    Seo, Ken
    Saito, Daisuke
    Oohashi, Kyoji
    TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 619 - 623
  • [33] Reliability of the Fat Tissue Channel for Intra-body Microwave Communication
    Asan, Noor Badariah
    Velander, Jacob
    Redzwan, Syaiful
    Augustine, Robin
    Hassan, Emadeldeen
    Noreland, Daniel
    Voigt, Thiemo
    Blokhuis, Taco J.
    2017 IEEE CONFERENCE ON ANTENNA MEASUREMENTS & APPLICATIONS (CAMA), 2017, : 310 - 313
  • [34] Characterization of an Intra-Body Wireless Link in the UHF Band
    Mghar, Fatiha
    Diet, Antoine
    Gannouni, Chadi
    Pichon, Lionel
    Meyer, Olivier
    Koulouridis, Stavros
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2022, 111 : 247 - 259
  • [35] Low Profile Implantable Antenna for Fat Intra-Body Communication
    Mandal, Bappaditya
    Joseph, Laya
    Ebrahimizadeh, Javad
    Perez, Mauricio D.
    Mitra, Debasis
    Augustine, Robin
    2020 14TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP 2020), 2020,
  • [36] Channel Characteristics Analysis of Galvanic Coupling Intra-Body Communication
    Li, Jia Wen
    Chen, Xi Mei
    Sekar, Booma Devi
    Lam, Chan Tong
    Du, Min
    Mak, Peng Un
    Vai, Mang I.
    Gao, Yue Ming
    Pun, Sio Hang
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2022, 6 (03): : 364 - 372
  • [37] Characterization of an Intra-Body Wireless Link in the UHF Band
    Mghar F.
    Diet A.
    Gannouni C.
    Pichon L.
    Meyer O.
    Koulouridis S.
    Progress In Electromagnetics Research M, 2022, 111 : 247 - 259
  • [38] Stochastic Noise Model for Intra-body Terahertz Nanoscale Communication
    Elayan, Hadeel
    Stefanini, Cesare
    Shubair, Raed M.
    Jornet, Josep M.
    ACM NANOCOM 2018: 5TH ACM INTERNATIONAL CONFERENCE ON NANOSCALE COMPUTING AND COMMUNICATION, 2018,
  • [39] Intra-Body Channel Characterization of Medical Implant Devices
    De Santis, Valerio
    Feliziani, Mauro
    10TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, 2011, : 816 - 819
  • [40] Intra-Body Communication Model Based on Variable Biological Parameters
    Khorshid, Ahmed E.
    Eltawil, Ahmed M.
    Kurdahi, Fadi
    2015 49TH ASILOMAR CONFERENCE ON SIGNALS, SYSTEMS AND COMPUTERS, 2015, : 948 - 951