Wide Frequency Characterization of Intra-Body Communication for Leadless Pacemakers

被引:21
作者
Maldari, Mirko [1 ,2 ]
Albatat, Mohammad [3 ]
Bergsland, Jacob [3 ]
Haddab, Youcef [1 ]
Jabbour, Chadi [2 ]
Desgreys, Patricia [2 ]
机构
[1] Microport CRM, F-92140 Clamart, France
[2] Inst Polytech Paris, Telecom Paris, LTCI, F-91120 Palaiseau, France
[3] Oslo Univ Hosp, Rikshosp, Intervent Ctr, Oslo, Norway
基金
欧盟地平线“2020”;
关键词
Solid modeling; Electrodes; Pacemakers; Lead; Heart; Computational modeling; Probes; Intra-body communication; human body communication; leadless pacemaker; COMPLICATIONS; POPULATION; IMPEDANCE; COHORT; AREA;
D O I
10.1109/TBME.2020.2980205
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Leadless Cardiac Pacemakers (LCP) have the potential to revolutionize Cardiac Rhythm Management (CRM). Current LCPs can only pace a single location of the heart limiting their use to patients requiring singlechamber stimulation. A Multi-node system of synchronized LCPs could be used in a significantly larger patient population. Synchronization using standard communication techniques involves high power consumption decreasing the longevity of the device. In this work, we investigate Galvanic Intra Body Communication (IBC) as a method to synchronize multi-node LCP systems. First, an accurate computational torso model was used for quasi-static simulations to estimate channel pathloss in the frequency range [40 kHz-20 MHz]. The model was then verified with in-vivo measurements using a novel experimental setup, where two LCP devices were placed in the right atrium, right ventricle and left ventricle. All channels involved in a potential multi-node LCP system were characterized. The orientation of the transducers relative to each other had a great impact on the results, with the attenuation level ranging between 55 dB and 70 dB between the best and worst orientations. The best results were achieved in the MHz range. Coupled with the fact that it does not require additional electrodes, this study suggests Galvanic IBC be superior to conventional communication methods for LCP devices. This analysis defines a methodology for galvanic IBC channel characterization for LCP systems, which is an important step for the design of efficient transceivers for IBC applications. More experiments with larger datasets are needed to bring this method to practice.
引用
收藏
页码:3223 / 3233
页数:11
相关论文
共 37 条
  • [1] Albatat M., 2019, ANN BIOMED ENG, V48, P1
  • [2] Alquaydheb IbrahimN., 2019, Advances in Body Area Networks I, P267
  • [3] Measurement Issues in Galvanic Intrabody Communication: Influence of Experimental Setup
    Amparo Callejon, M.
    Reina-Tosina, Javier
    Naranjo-Hernandez, David
    Roa, Laura M.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (11) : 2724 - 2732
  • [4] [Anonymous], 2007, THESIS
  • [5] [Anonymous], SIMPLEWARE FE NURBS
  • [6] ELECTRODE-ELECTROLYTE INTERFACE IMPEDANCE - EXPERIMENTS AND MODEL
    BATES, JB
    CHU, YT
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1992, 20 (03) : 349 - 362
  • [7] Fundamental Characterization of Conductive Intracardiac Communication for Leadless Multisite Pacemaker Systems
    Bereuter, Lukas
    Kuenzle, Timon
    Niederhauser, Thomas
    Kucera, Martin
    Obrist, Dominik
    Reichlin, Tobias
    Tanner, Hildegard
    Haeberlin, Andreas
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2019, 13 (01) : 237 - 247
  • [8] Leadless cardiac resynchronization therapy: An in vivo proof-of-concept study of wireless pacemaker synchronization
    Bereuter, Lukas
    Niederhauser, Thomas
    Kucera, Martin
    Loosli, Dominic
    Steib, Immanuel
    Schildknecht, Marcel
    Zurbuchen, Adrian
    Noti, Fabian
    Tanner, Hildegard
    Reichlin, Tobias
    Haeberlin, Andreas
    [J]. HEART RHYTHM, 2019, 16 (06) : 936 - 942
  • [9] Leadless Dual-Chamber Pacing A Novel Communication Method for Wireless Pacemaker Synchronization
    Bereuter, Lukas
    Gysin, Mirco
    Kueffer, Thomas
    Kucera, Martin
    Niederhauser, Thomas
    Fuhrer, Juerg
    Heinisch, Paul
    Zurbuchen, Adrian
    Obrist, Dominik
    Tanner, Hildegard
    Haeberlin, Andreas
    [J]. JACC-BASIC TO TRANSLATIONAL SCIENCE, 2018, 3 (06): : 813 - 823
  • [10] Leadless pacemakers: a contemporary review
    Bhatia, Neal
    El-Chami, Mikhael
    [J]. JOURNAL OF GERIATRIC CARDIOLOGY, 2018, 15 (04) : 249 - 253