Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Balloon-Expandable Transcatheter Heart Valve A Single-Center Experience

被引:46
|
作者
Husser, Oliver [1 ]
Pellegrini, Costanza [1 ]
Kessler, Thorsten [1 ]
Burgdorf, Christof [1 ]
Thaller, Hannah [1 ]
Mayr, N. Patrick [2 ]
Ott, Ilka [1 ]
Kasel, Albert M. [1 ]
Schunkert, Heribert [1 ,3 ]
Kastrati, Adnan [1 ,3 ]
Hengstenberg, Christian [1 ,3 ]
机构
[1] Tech Univ Munich, Deutsch Herzzentrum Munchen, Klin Herz & Kreislauferkrankungen, D-80636 Munich, Germany
[2] Tech Univ Munich, Deutsch Herzzentrum Munchen, Inst Anasthesiol, D-80636 Munich, Germany
[3] Deutsch Zentrum Herz & Kreislauf Forsch DZHK eV, German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, Munich, Germany
关键词
aortic valve stenosis; outcome; SAPIEN; 3; transfemoral transcatheter aortic valve implantation; VARC-2; PERMANENT PACEMAKER IMPLANTATION; SAPIEN; 3; EDWARDS SAPIEN; VASCULAR COMPLICATIONS; RISK; STENOSIS; METAANALYSIS; DEFINITIONS; PREDICTORS; COREVALVE;
D O I
10.1016/j.jcin.2015.08.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES Evaluation of 30-day outcomes after transcatheter aortic valve replacement (TAVR) with the novel balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV) (Edwards Lifesciences, Irvine, California) emphasizing the updated Valve Academic Research Consortium (VARC-2) criteria. BACKGROUND Preliminary data on clinical performance with the S3 THV are promising. However, information regarding 30-day outcome is limited. METHODS A total of 250 consecutive patients undergoing transfemoral TAVR with the S3 THV at our center were enrolled, and outcomes according to VARC-2 criteria were analyzed at 30 days. RESULTS The mean age was 81.0 +/- 6.2 years, median logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) and Society of Thoracic Surgeons score were 12.1% and 4.4%, respectively. VARC-2-defined device success was achieved in 244 patients (97.6%); moderate paravalvular leakage developed in 5 patients (2.0%). One patient (0.4%) died of a noncardiac cause and 8 patients (3.2%) had a stroke. Life-threatening bleeding and major vascular complications occurred in 12 (4.8%) and 9 (3.6%) of the patients, respectively. From discharge to 30 days, 5 patients (2.0%) were hospitalized due to valve-related symptoms or worsening of heart failure. The VARC-2 composite early safety endpoint was observed in 25 patients (10.0%). Permanent pacemaker implantation rate at 30 days was 15.2%. Myocardial infarction, coronary obstruction requiring intervention, valve-related dysfunction, and endocarditis were not observed. CONCLUSIONS We found very good 30-day results using the novel S3 THV with a low rate of clinical events according to VARC-2 criteria. The S3 THV is associated with high procedural success and favorable early safety profile. The need for pacemaker implantations appears to be more frequent than with its predecessor. (C) 2015 by the American College of Cardiology Foundation.
引用
收藏
页码:1809 / 1816
页数:8
相关论文
共 50 条
  • [21] BALLOON-EXPANDABLE VERSUS SELF-EXPANDABLE TRANSCATHETER AORTIC VALVE REPLACEMENT
    Okumura, L.
    Sanchez, L.
    Alves, M.
    Candolfi, P.
    VALUE IN HEALTH, 2021, 24 : S68 - S68
  • [22] Transcatheter Aortic Valve Replacement With a Balloon-expandable Valve for the Treatment of Noncalcified Bicuspid Aortic Valve Disease
    Urena, Marina
    Doyle, Daniel
    Dumont, Eric
    Ribeiro, Henrique Barbosa
    Bilodeau, Sylvie
    Rodes-Cabau, Josep
    REVISTA ESPANOLA DE CARDIOLOGIA, 2014, 67 (04): : 327 - 329
  • [23] Procedural and clinical outcomes of the valve-in-valve technique for severe aortic insufficiency after balloon-expandable transcatheter aortic valve replacement
    Giri, Jay
    Bortnick, Anna E.
    Wallen, Tyler
    Walsh, Elizabeth
    Bannan, Amr
    Desai, Nimesh
    Szeto, Wilson Y.
    Bavaria, Joseph
    Herrmann, Howard C.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (01) : 139 - 147
  • [24] Impact of Aortic Valve Calcification on Acute Elastic Recoil of a Balloon-Expandable Valve After Transcatheter Aortic Valve Replacement
    Yoshihara, Nagataka
    Akahori, Hirokuni
    Tanaka, Takamasa
    Yanaka, Koji
    Kimura, Toshio
    Miki, Kojiro
    Imanaka, Takahiro
    Ishihara, Masaharu
    CIRCULATION, 2019, 140
  • [25] Impact of Tricuspid Regurgitation on Outcomes of Transcatheter Aortic Valve Replacement With Balloon-Expandable Valves
    Zahr, Firas
    Elmariah, Sammy
    Vemulapalli, Sreekanth
    Kodali, Susheel K.
    Hahn, Rebecca T.
    Anderson, Allen S.
    Eleid, Mackram F.
    Davidson, Charles J.
    Sharma, Rahul P.
    O'Neill, William W.
    Bethea, Brian
    Thourani, Vinod H.
    Chakravarty, Tarun
    Gupta, Aakriti
    Makkar, Raj R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (16) : 1916 - 1931
  • [26] Efficacy of larger valve sizing with underfilling in balloon-expandable transcatheter aortic valve replacement
    Kawaguchi, Tomohiro
    Miyoshi, Toru
    Hayashi, Masaomi
    Ishizu, Kenichi
    Ugawa, Satoko
    Nosaka, Kazumasa
    Isotani, Akihiro
    Doi, Masayuki
    Shirai, Shinichi
    Ando, Kenji
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (07) : 2082 - 2091
  • [27] Outcomes of repeat transcatheter aortic valve replacement with balloon-expandable valves: a registry study
    Makkar, Raj R.
    Kapadia, Samir
    Chakravarty, Tarun
    Cubeddu, Robert J.
    Kaneko, Tsuyoshi
    Mahoney, Paul
    Patel, Dhairya
    Gupta, Aakriti
    Cheng, Wen
    Kodali, Susheel
    Bhatt, Deepak L.
    Mack, Michael J.
    Leon, Martin B.
    Thourani, Vinod H.
    LANCET, 2023, 402 (10412): : 1529 - 1540
  • [28] Balloon-Expandable Transcatheter Heart Valve Geometry in Low-Risk Bicuspid Patients Undergoing Transcatheter Aortic Valve Replacement
    Medranda, Giorgio
    Rogers, Toby
    Case, Brian
    Ali, Syed
    Shea, Corey
    Zhang, Cheng
    Asch, Federico
    Weissman, Gaby
    Shults, Christian
    Garcia-Garcia, Hector
    Ben-Dor, Itsik
    Satler, Lowell
    Waksman, Ron
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (19) : B153 - B154
  • [29] The Cusp-Overlap Technique for Transcatheter Aortic Valve Replacement With a Balloon-Expandable Valve
    Akodad, Mariama
    Blanke, Philipp
    Nestelberger, Thomas
    Alosail, Abdulmajeed
    Chatfield, Andrew
    Leipsic, Jonathon
    Tzimas, Georgios
    Lounes, Youcef
    Meier, David
    Sathananthan, Janarthanan
    Wood, David
    Webb, John
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B199 - B199
  • [30] Transcatheter Aortic Valve Replacement with a New Balloon Expandable Percutaneous Heart Valve
    Binder, Ronald
    Rodes-Cabau, Josep
    Wood, David
    Mok, Michael
    Leipsic, Jonathon
    De Larochelliere, Robert
    Toggweiler, Stefan
    Dumont, Eric
    Freeman, Melanie
    Willson, Alex
    Webb, John
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B237 - B237