Blood flow through sutured and coupled microvascular anastomoses: A comparative computational study

被引:31
作者
Wain, Richard A. J. [1 ,2 ,3 ]
Whitty, Justin P. M. [2 ]
Dalal, Milind D. [3 ]
Holmes, Michael C. [4 ]
Ahmed, Waqar [5 ]
机构
[1] Christie Hosp NHS Fdn Trust, Dept Plast & Reconstruct Surg, Manchester M20 4BX, Lancs, England
[2] Univ Cent Lancashire, Sch Comp Engn & Phys Sci, Preston PR1 2HE, Lancs, England
[3] Lancashire Teaching Hosp NHS Fdn Trust, Royal Preston Hosp, Dept Plast & Reconstruct Surg, Preston PR2 9HT, Lancs, England
[4] Univ Cent Lancashire, Grad Res Sch, Preston PR1 2HE, Lancs, England
[5] Univ Cent Lancashire, Sch Postgrad Med & Dent, Preston PR1 2HE, Lancs, England
关键词
Microvascular; Anastomosis; Computational modelling; Sutured; Coupled; Coupler; FREE TISSUE TRANSFER; SHEAR-STRESS; BREAST RECONSTRUCTION; CLINICAL-EXPERIENCE; VENOUS THROMBOSIS; GLYCOPROTEIN-IB; FLAP; ATHEROSCLEROSIS; SUBENDOTHELIUM; COAGULATION;
D O I
10.1016/j.bjps.2014.03.016
中图分类号
R61 [外科手术学];
学科分类号
摘要
This study uses computational fluid dynamics (CFD) to model blood flow through idealised sutured and coupled arterial anastomoses to investigate the affect of each technique on intravascular blood flow. Local flow phenomena are examined in detail to study characteristics that potentially initiate thrombus formation; for example, changes in velocity profile, wall shear stress (WSS), and shear strain rate (SSR). Idealised geometries of sutured and coupled anastomoses were created with dimensions identical to microvascular suture material and a commercially available coupling device using CFD software. Vessels were modelled as non-compliant 1 mm diameter ducts, and blood was simulated as a Newtonian fluid, in keeping with previous studies. All analyses were steady-state and performed on arteries. The sutured simulation revealed a reduced boundary velocity profile; high WSS; and high SSR at the suture sites. The coupled anastomosis simulation showed a small increase in maximum WSS at the anastomotic region compared to a pristine vessel, however, this was less than half that of the sutured model. The coupled vessel displayed an average WSS equivalent to a pristine vessel simulation. Taken together these observations demonstrate a theoretically more thrombogenic profile in a sutured anastomosis when compared to a coupled vessel. Data from simulations on a coupled anastomosis reveal a profile that is nearly equivalent to that of a pristine vessel. Based purely on the combination of less favourable flow properties shown using these idealised arterial models, the sutured method is potentially more thrombogenic than a coupled anastomosis. (C) 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:951 / 959
页数:9
相关论文
共 38 条
[31]  
ROTH GJ, 1991, BLOOD, V77, P5
[32]   THE ROLE OF PLATELET MEMBRANE GLYCOPROTEIN-IB AND IIB-IIIA IN PLATELET ADHERENCE TO HUMAN ARTERY SUBENDOTHELIUM [J].
SAKARIASSEN, KS ;
NIEVELSTEIN, PFEM ;
COLLER, BS ;
SIXMA, JJ .
BRITISH JOURNAL OF HAEMATOLOGY, 1986, 63 (04) :681-691
[33]   Wall shear stress and early atherosclerosis: A review [J].
Shaaban, AM ;
Duerinckx, AJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (06) :1657-1665
[34]   Threshold Response of Initiation of Blood Coagulation by Tissue Factor in Patterned Microfluidic Capillaries Is Controlled by Shear Rate [J].
Shen, Feng ;
Kastrup, Christian J. ;
Liu, Ying ;
Ismagilov, Rustem F. .
ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2008, 28 (11) :2035-U226
[35]   Routine use of microvascular coupling device for arterial anastomosis in breast reconstruction [J].
Spector, JA ;
Draper, LB ;
Levine, JP ;
Ahn, CY .
ANNALS OF PLASTIC SURGERY, 2006, 56 (04) :365-368
[36]   ROLE OF SHEAR RATE AND PLATELETS IN PROMOTING FIBRIN FORMATION ON RABBIT SUBENDOTHELIUM - STUDIES UTILIZING PATIENTS WITH QUANTITATIVE AND QUALITATIVE PLATELET DEFECTS [J].
WEISS, HJ ;
TURITTO, VT ;
BAUMGARTNER, HR .
JOURNAL OF CLINICAL INVESTIGATION, 1986, 78 (04) :1072-1082
[37]   Venous thrombosis in coupled versus sutured microvascular anastomoses [J].
Yap, Lok H. ;
Constantinides, Joannis ;
Butler, Charles E. .
ANNALS OF PLASTIC SURGERY, 2006, 57 (06) :666-669
[38]   Clinical experience with non-penetrating vascular clips in free-flap reconstructions [J].
Zeebregts, C ;
Acosta, R ;
Bölander, L ;
van Schilfgaarde, R ;
Jakobsson, O .
BRITISH JOURNAL OF PLASTIC SURGERY, 2002, 55 (02) :105-110