摘要
Background: During the last few years, several different devices have been proposed for atrial septal defect (ASD) percutaneous closure. For the Amplatzer Septal Occluder (ASO) device, accurate balloon sizing is considered of paramount importance because the prosthesis waist has to be exactly adjusted to the defect diameter (+/- 1 mm). In this study, we aimed to demonstrate the possibility of marked misinterpreting of the actual defect size using the balloon technique in patients with secundum ASD and to evaluate the accuracy of intracardiac echocardiography (ICE) measurements as a new method for selecting the size of ASO device. Methods: Between February 1999 and December 2000, 166 consecutive adult patients underwent percutaneous transvenous secundum ASD occlusion using the ASO device. In 124 patients (control group), ASD were closed by conventional methods. In 13 patients (pilot group), balloon pulling technique was used in size selection, whereas ICE was used on-line to monitor device placement and off-line to assess its possibilities for accurate quantitative measurements and qualitative evaluation. In 31 patients (study group), ICE was used as the sole imaging tool both for guiding device selection and monitoring the procedure. All patients underwent complete transthoracic echocardiographic study before discharge and during follow-up visits at 3 and 12 months. Results: Successful device implantation was accomplished in 163 of the 166 patients (98.2%). Short-term follow-up results were available in all eligible patients at least 3 months. Complete occlusion was demonstrated in 91.4% and 92.2% of patients in the control and pilot groups, respectively, increasing to 97.3% in the study group (p < 0.01 vs. both control and pilot groups). There were no significant differences in mean ASO diameters in the control and pilot groups (20 +/- 7.7 and 22 +/- 5.4 mm, respectively), whereas the mean size of the devices used in the study group was significantly larger (27.4 +/- 6.2 mm, p < 0.01 vs. both control and pilot groups). In the pilot group, the underestimation effect of the balloon strategy was evident, with a mean 12.3% larger diameter required on ICE measurements. Moreover, a misalignment between the ASO and the atrial septum was seen on ICE in 9 of 13 patients of the pilot group, whereas good apposition of the ASO on the septum secundum was seen in all patients of the study group. Conclusion: ICE is a safe and effective method for selecting ASO size and continuous monitoring of the procedure. In contrast to the previously reported implantation procedure (device-to-defect ratio 1:1), a device 10-20% larger than invasively measured stretched defect diameter should be chosen and implanted on the basis of the ICE data. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:61 / 68
页数:8
相关论文
共 50 条
  • [31] Impact of the Amplatzer Atrial Septal Occluder Device on Left Ventricular Function in Pediatric Patients
    Biagio Castaldi
    Giuseppe Santoro
    Giovanni Di Salvo
    Gianpiero Gaio
    Maria Teresa Palladino
    Fabio D’Aiello
    Carola Iacono
    Giuseppe Pacileo
    Raffaele Calabrò
    Maria Giovanna Russo
    Pediatric Cardiology, 2013, 34 : 1645 - 1651
  • [32] Long-Term Follow Up of Secundum Atrial Septal Defect Closure with the Amplatzer Septal Occluder
    Knepp, Marc D.
    Rocchini, Albert P.
    Lloyd, Thomas R.
    Aiyagari, Ranjit M.
    CONGENITAL HEART DISEASE, 2010, 5 (01) : 32 - 37
  • [33] The repeating dislodgement of an Amplatzer Septal Occluder device during recovery from general anesthesia in an adult undergoing transcatheter closure of atrial septal defect : a case report
    Abe, Natsuki
    Go, Masanori
    Nakai, Kaori
    Kato, Michihisa
    Tanaka, Katsuya
    JOURNAL OF MEDICAL INVESTIGATION, 2019, 66 (1-2) : 194 - 198
  • [34] Stretched Size of Atrial Septal Defect Predicted by Intracardiac Echocardiography
    Lin, Ming-Chih
    Fu, Yun-Ching
    Jan, Sheng-Ling
    Ho, Chi-Lin
    Hwang, Betau
    INTERNATIONAL HEART JOURNAL, 2010, 51 (01) : 56 - 59
  • [35] Reliability of transthoracic echocardiography in estimating the size of Amplatzer septal occluder and guiding percutaneous closure of atrial septal defects
    Li Gui-shuang
    Kong Guang-ming
    Ji Qiu-shang
    Li Ji-fu
    Chen Yu-guo
    You Bei-an
    Zhang Yun
    CHINESE MEDICAL JOURNAL, 2008, 121 (11) : 973 - 976
  • [36] Sizing of atrial septal defects by intracardiac echocardiography for device closures
    Chien, Jen-Chung
    Hwang, Betau
    Fu, Yun-Ching
    Lee, Pi-Chang
    Hsieh, Kai-Sheng
    Jan, Sheng-Ling
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2008, 71 (08) : 399 - 405
  • [37] Novel technique to prevent prolapse of the amplatzer septal occluder through large atrial septal defect
    Wahab, HA
    Bairam, AR
    Cao, QL
    Hijazi, ZM
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (04) : 543 - 545
  • [38] Late failure of atrial septal defect occluder device
    Francois-Pierre, Mouthuy
    Nicolas, Floris
    Marie-France, Leloux
    Spiridon, Papadatos
    Denis, Pieters
    Christophe, Laruelle
    ACTA CARDIOLOGICA, 2021, 76 (06) : 676 - 677
  • [39] Impact of right ventricular size on ECG after percutaneous closure of atrial septal defect with Amplatzer Septal Occluder
    Di Bernardo, S
    Berger, F
    Fasnacht, M
    Bauersfeld, U
    SWISS MEDICAL WEEKLY, 2005, 135 (43-44) : 647 - 651
  • [40] Percutaneous transcatheter atrial septal defect closure with Amplatzer septal occluder device using three different techniques in three adult patients with complex ostium secundum type atrial defects
    Kilic, Teoman
    Sahin, Tayfun
    Ural, Ertan
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2013, 41 (02): : 148 - 153