Damage Patterns at the Head-Stem Taper Junction Helps Understand the Mechanisms of Material Loss

被引:24
作者
Hothi, Harry S. [1 ]
Panagiotopoulos, Andreas C. [1 ]
Whittaker, Robert K. [1 ]
Bills, Paul J. [2 ]
McMillan, Rebecca A. [1 ]
Skinner, John A. [1 ]
Hart, Alister J. [1 ]
机构
[1] Univ Coll London, Inst Orthopaed & Musculoskeletal Sci, Stanmore, Middx, England
[2] Univ Huddersfield, Ctr Precis Technol, Huddersfield, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
metal-on-metal; taper; material loss; wear; corrosion; retrieval; ON-METAL BEARINGS; CORROSION;
D O I
10.1016/j.arth.2016.06.045
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Material loss at the taper junction of metal-on-metal total hip arthroplasties has been implicated in their early failure. The mechanisms of material loss are not fully understood; analysis of the patterns of damage at the taper can help us better understand why material loss occurs at this junction. Methods: We mapped the patterns of material loss in a series of 155 metal-on-metal total hip arthroplasties received at our center by scanning the taper surface using a roundness-measuring machine. We examined these material loss maps to develop a 5-tier classification system based on visual differences between different patterns. We correlated these patterns to surgical, implant, and patient factors known to be important for head-stem taper damage. Results: We found that 63 implants had "minimal damage" at the taper (material loss <1 mm(3)), and the remaining 92 implants could be categorized by 4 distinct patterns of taper material loss. We found that (1) head diameter and (2) time to revision were key significant variables separating the groups. Conclusion: These material loss maps allow us to suggest different mechanisms that dominate the cause of the material loss in each pattern: (1) corrosion, (2) mechanically assisted corrosion, or (3) intraoperative damage or poor size tolerances leading to toggling of trunnion in taper. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:291 / 295
页数:5
相关论文
共 14 条
[1]  
[Anonymous], BONE JOINT J S12
[2]   Wear patterns of taper connections in retrieved large diameter metal-on-metal bearings [J].
Bishop, Nicholas ;
Witt, Florian ;
Pourzal, Robin ;
Fischer, Alfons ;
Ruetschi, Marcel ;
Michel, Markus ;
Morlock, Michael .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (07) :1116-1122
[3]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, P305
[4]   The Influence of Head Size on Corrosion and Fretting Behaviour at the Head-Neck Interface of Artificial Hip Joints [J].
Dyrkacz, Richard M. R. ;
Brandt, Jan-M. ;
Ojo, Olanrewaju A. ;
Turgeon, Thomas R. ;
Wyss, Urs P. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (06) :1036-1040
[5]   IN-VIVO CORROSION OF MODULAR HIP-PROSTHESIS COMPONENTS IN MIXED AND SIMILAR METAL COMBINATIONS - THE EFFECT OF CREVICE, STRESS, MOTION, AND ALLOY COUPLING [J].
GILBERT, JL ;
BUCKLEY, CA ;
JACOBS, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (12) :1533-1544
[6]  
Goldberg JR, 2002, CLIN ORTHOP RELAT R, P149
[7]  
Higgs G, 2013, BONE JOINT J B S15, V95-B, P108
[8]   The Reliability of a Scoring System for Corrosion and Fretting, and Its Relationship to Material Loss of Tapered, Modular Junctions of Retrieved Hip Implants [J].
Hothi, Harry S. ;
Matthies, Ashley K. ;
Berber, Reshid ;
Whittaker, Robert K. ;
Skinner, John A. ;
Hart, Alister J. .
JOURNAL OF ARTHROPLASTY, 2014, 29 (06) :1313-1317
[9]  
JACOBS JJ, 1995, CLIN ORTHOP RELAT R, P94
[10]  
Jacobs JJ, 2013, J BONE JOINT SURG AM, V95A, P1629, DOI [10.2106/JBJS.M.00137, 10.2106/JBJS.L.01370]