Effects of postural change on transesophageal echocardiography views and parameters in healthy dogs

被引:5
作者
Goya, Seijirow [1 ]
Wada, Tomoki [1 ]
Shimada, Kazumi [1 ]
Hirao, Daiki [1 ]
Fukushima, Ryuji [1 ]
Yamagishi, Norio [2 ]
Shimizu, Miki [3 ]
Tanaka, Ryou [1 ]
机构
[1] Tokyo Univ Agr & Technol, Fac Vet Med, Dept Vet Surg, 3-5-8 Saiwai Cho, Fuchu, Tokyo 1830052, Japan
[2] Iwate Univ, Fac Agr, Dept Vet Clin Med, 3-18-8 Ueda Cho, Morioka, Iwate 0208550, Japan
[3] Tokyo Univ Agr & Technol, Dept Vet Diagnost Imaging, Fac Vet Med, 3-5-8 Saiwai Cho, Fuchu, Tokyo 1830052, Japan
关键词
cardiovascular system; dog; echocardiography; ultrasound; SYSTOLIC-TIME INTERVALS; PATENT DUCTUS-ARTERIOSUS; ESOPHAGEAL DOPPLER; CARDIAC-SURGERY; VENTRICULAR VOLUMES; EJECTION FRACTION; STROKE VOLUME; OCCLUSION; POSITIONS; EXERCISE;
D O I
10.1292/jvms.16-0323
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The purpose of the present study is to investigate the effect of postural change on transesophageal echocardiography (TEE) views and parameters of interest anesthesia monitoring in healthy dogs. Twelve Beagle dogs were anesthetized and randomly positioned in one of four postures: right lateral-recumbency, left lateral-recumbency, supine position and prone position. After examinations in one posture, the same examination was demonstrated in another posture and repeated in all postures. In each posture, several standard TEE views were demonstrated: longitudinal cranial-esophageal aorta long-axis-view, transverse middle-esophageal mitral valve long-axis-view and transgastric middle short-axis-view. Additionally, echocardiographic parameters were attempted to measure, and direct blood pressure monitoring was performed in each view. As a result, oriented views, except for transgastric middle short-axis-view, could be obtained in all postures. Stroke volume and peak early diastolic velocity of mitral inflow were lower in supine position compared with those in right and left lateral-recumbency. Heart rate (HR) and systemic vascular resistance were higher in supine position compared with those in right and left lateral-recumbency. Left ventricular pre-ejection period/left ventricular ejection time corrected and uncorrected by HR were higher in supine position compared with those in right and left lateral-recumbency. In conclusion, longitudinal cranial-esophageal aorta long-axis-view and transverse middle-esophageal mitral valve long-axis-view provide useful information of interest anesthesia monitoring, because of their views enable to certainly obtain TEE parameters in various postures. Furthermore, TEE parameters allow to detect the changes of preload, afterload and HR that occur in supine position dogs.
引用
收藏
页码:380 / 386
页数:7
相关论文
共 43 条
  • [1] Utility of transesophageal echocardiography during port-access minimally invasive cardiac surgery
    Applebaum, RM
    Cutler, WM
    Bhardwaj, N
    Colvin, SB
    Galloway, AC
    Ribakove, GH
    Grossi, EA
    Schwartz, DS
    Anderson, RV
    Tunick, PA
    Kronzon, I
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (02) : 183 - 188
  • [2] PHARMACODYNAMICS OF A SINGLE DOSE OF QUINIDINE DURING CHRONIC DIGOXIN TREATMENT - A RANDOMIZED DOUBLE-BLIND PLACEBO AND SPARTEINE CONTROLLED CROSSOVER STUDY
    BELZ, GG
    AUST, PE
    DOERING, W
    HEINZ, M
    SCHNEIDER, B
    [J]. EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1982, 22 (02) : 117 - 122
  • [3] Bornscheuer A, 1996, J EXP ANIM SCI, V38, P20
  • [4] AUTONOMIC CARDIAC CONTROL .2. NONINVASIVE INDEXES AND BASAL RESPONSE AS REVEALED BY AUTONOMIC BLOCKADES
    CACIOPPO, JT
    BERNTSON, GG
    BINKLEY, PF
    QUIGLEY, KS
    UCHINO, BN
    FIELDSTONE, A
    [J]. PSYCHOPHYSIOLOGY, 1994, 31 (06) : 586 - 598
  • [5] The effect of the lateral decubitus position on vagal tone
    Chen, GY
    Kuo, CD
    [J]. ANAESTHESIA, 1997, 52 (07) : 653 - 657
  • [6] COKKINOS DV, 1976, BRIT HEART J, V38, P683
  • [7] Cardiac output determination during experimental hemorrhage and resuscitation using a transesophageal doppler monitor
    de Figueiredo, LFP
    Cruz, RJ
    Silva, E
    Silva, MRE
    [J]. ARTIFICIAL ORGANS, 2004, 28 (04) : 338 - 342
  • [8] DOERING L, 1988, NURS RES, V37, P114
  • [9] Transoesophageal echocardiography in the dog
    Domenech, Oriol
    Oliveira, Pedro
    [J]. VETERINARY JOURNAL, 2013, 198 (02) : 329 - 338
  • [10] Dulchavsky SA, 1999, J TRAUMA, V46, P611