A validation study of a smartphone application for heart rate variability assessment in asymptomatic adults

被引:0
作者
Gambassi, Bruno Bavaresco [1 ,2 ]
Neves, Victor Ribeiro [1 ,3 ]
Alves Brito, Einstein Zeus [1 ,4 ]
da Silva Fernandes, Danilo Sobral [1 ,4 ,5 ]
Sa, Camila Almeida [1 ,4 ,5 ]
Rocha Nogueira, Raquel Moraes [2 ]
Furtado Almeida, Fabiano de Jesus [11 ]
de Araujo Cavalcanti, Pedro Augusto [4 ]
Gomes Goncalves e Silva, Daniela Conceicao [1 ,6 ]
Neto, Danilo Sobreira [1 ,5 ,7 ]
de Souza Mesquita, Fabricio Olinda [1 ,4 ,6 ,7 ]
Gaspar Novais, Tania Maria [2 ]
Matias de Souza, Vania de Fatima [8 ]
Cerqueira Oliveira, Antonio Carlos [1 ,9 ]
Leite, Richard Diego [10 ]
Schwingel, Paulo Adriano [1 ,3 ,6 ]
机构
[1] Univ Pernambuco UPE, Lab Pesquisas Desempenho Humano LAPEDH, BR-56328900 Petrolina, PE, Brazil
[2] Univ Ceuma CEUMA, Programa Posgrad Gestao Programas & Serv Saude MG, BR-65075120 Sao Luis, MA, Brazil
[3] UPE, Programa Posgrad Reabilitacao & Desempenho Func P, BR-56328900 Petrolina, PE, Brazil
[4] Fac Tecnol Inspirar INSPIRAR, Curso Posgrad Fisioterapia Traumato Ortopedia & E, BR-56302280 Petrolina, PE, Brazil
[5] Inst Valler Med Integrada VALLER, Dept Med Esport, BR-48903055 Juazeiro, BA, Brazil
[6] Univ Pernambuco, Programa Posgrad Ciencias Saude PPGCS, BR-50100130 Recife, PE, Brazil
[7] Hosp Univ Univ Fed Vale Sao Francisco HU UNIVASF, Empresa Brasileira Serv Hosp EBSERH, BR-56304205 Petrolina, PE, Brazil
[8] Univ Estadual Maringa UEM, Dept Educ Fis DEF, BR-87020900 Maringa, Parana, Brazil
[9] Univ Fed Bahia UFBA, Complexo Hosp Univ Prof Edgard Santos HUPES, BR-40301155 Salvador, BA, Brazil
[10] Univ Fed Espirito Santo UFES, Ctr Educ Fis & Desportos CEFD, Lab Forca & Condicionamento, BR-2907591 Vitoria, ES, Brazil
[11] Univ Ceuma CEUMA, BR-65075120 Sao Luis, Maranhao, Brazil
来源
AMERICAN JOURNAL OF CARDIOVASCULAR DISEASE | 2020年 / 10卷 / 03期
关键词
Autonomic nervous system; heart rate; electrocardiography; mobile applications; RATE MONITOR; VALIDITY; INTERVALS; SYSTEM;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Assessment of heart rate variability (HRV) is an effective non-invasive tool to obtain data on cardiac autonomic modulation and may be assessed by a range of devices, including mobile applications. Objective: This study aimed to validate a smartphone application by comparingthe R-R intervals (RRi) obtained by the app with a classic electrocardiogram (ECG)-derived reference condition Methods: Fifteen asymptomatic adults (24.9 +/- 3.4 years) underwent an orthostatic challenge during which RRi were simultaneously recorded by a freeware smartphone application and by an ECG recorder. Pearson correlation coefficients (r) and coefficients of determination (r(2)) were calculated to determine the degree of association between the two electronic devices. Two-way repeated measures analysis of variance and Bland-Altman analysis were used to calculate the measurement consistency and agreement, respectively, between the two methods. Effect size was also used to estimate the magnitude of the differences. Results: The number of RRi from asymptomatic adults recorded by the ECG and by the free smartphone application was similar at rest in supine position (13,149 vs. 13,157; P = 0.432) and during orthostatic challenge (10,666 vs. 10,664 P = 0.532). RRi in milliseconds from both devices presented a near perfect correlation in the supine position (r = 0.999; Confidence Interval [CI] at 95%: 0.999-0.999; P < 0.0001) and during orthostatic challenge (r = 0.988; 95% CI: 0.988-0.989; P < 0.0001). A negative bias of -0.526 milliseconds (95% limits of agreement [LoA] from -4.319 to 3.266 milliseconds) was observed in supine position between ECG and the smartphone application. On the other hand, a positive bias of 0.077 milliseconds (95% LoA from -10.090 to 10.240 milliseconds) during the orthostatic challenge was observed. Conclusions: Our results cross-validated a freeware smartphone application with the ECG-derived reference condition for asymptomatic adults at rest in the supine position and during orthostatic challenge.
引用
收藏
页码:219 / 229
页数:11
相关论文
共 37 条
  • [31] The role of heart rate variability in prognosis for different modes of death in chronic heart failure
    Sandercock, Gavin Richard H.
    Brodie, David A.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (08): : 892 - 904
  • [32] Physiological Parameter Monitoring from Optical Recordings With a Mobile Phone
    Scully, Christopher G.
    Lee, Jinseok
    Meyer, Joseph
    Gorbach, Alexander M.
    Granquist-Fraser, Domhnull
    Mendelson, Yitzhak
    Chon, Ki H.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (02) : 303 - 306
  • [33] A healthy heart is not a metronome: an integrative review of the heart's anatomy and heart rate variability
    Shaffer, Fred
    McCraty, Rollin
    Zerr, Christopher L.
    [J]. FRONTIERS IN PSYCHOLOGY, 2014, 5
  • [34] A meta-analysis of heart rate variability and neuroimaging studies: Implications for heart rate variability as a marker of stress and health
    Thayer, Julian F.
    Ahs, Fredrik
    Fredrikson, Mats
    Sollers, John J., III
    Wager, Tor D.
    [J]. NEUROSCIENCE AND BIOBEHAVIORAL REVIEWS, 2012, 36 (02) : 747 - 756
  • [35] Quantitative beat-to-beat analysis of heart rate dynamics during exercise
    Tulppo, MP
    Makikallio, TH
    Takala, TES
    Seppanen, T
    Huikuri, HV
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1996, 271 (01): : H244 - H252
  • [36] A Possibility of Active Controlled Installation for Deep Water Subsea Production Modules
    Watanabe, Keisuke
    [J]. PROCEEDINGS OF THE 2012 FIFTH INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN ENGINEERING AND TECHNOLOGY (ICETET 2012), 2012, : 163 - 166
  • [37] Comparison of three mobile devices for measuring R-R intervals and heart rate variability: Polar S810i, Suunto t6 and an ambulatory ECG system
    Weippert, Matthias
    Kumar, Mohit
    Kreuzfeld, Steffi
    Arndt, Dagmar
    Rieger, Annika
    Stoll, Regina
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 109 (04) : 779 - 786