Equal tibial component fixation of a mobile-bearing and fixed-bearing medial unicompartmental knee arthroplasty: a randomized controlled RSA study with 2-year follow-up

被引:12
作者
Koppens, Daan [1 ]
Rytter, Soren [1 ]
Munk, Stig [1 ]
Dalsgaard, Jesper [1 ]
Sorensen, Ole G. [2 ]
Hansen, Torben B. [1 ]
Stilling, Maiken [1 ]
机构
[1] Hosp Unit West Holstebro, Univ Clin Hand Hip & Knee Surg, Dept Orthoped Surg, Holstebro, Denmark
[2] Aarhus Univ Hosp, Dept Orthoped Surg, Aarhus, Denmark
关键词
ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS; OXFORD HIP; REPLACEMENT; MIGRATION; POWER;
D O I
10.1080/17453674.2019.1639965
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose - Differences in stress distribution in a mobile-bearing and fixed-bearing unicompartmental knee arthroplasty (UKA) design might lead to a difference in fixation of the tibial component. We compared tibial component migration of a mobile-bearing (MB) UKA and a fixed-bearing (FB) UKA using radiostereometric analysis. Patients and methods - In a randomized, patient-blinded clinical trial 62 patients received either the MB Oxford UKA or the FB Sigma UKA. The patients were followed for 24 months with radiostereometric analysis. Clinical outcome was assessed with Oxford Knee Score (OKS), RAND-36 and leg extension power. Results - Migration of the tibial components was similar between groups throughout follow-up. At 12 months, MTPM of the tibial component was 0.44 mm (95% CI 0.34-0.55) for the MB group and 0.40 mm (CI 0.31-0.50) for the FB group. Between 12 and 24 months, the tibial components migrated with a median MTPM increase of 0.03 mm (CI -0.02 to 0.08) in the MB group and 0.03 mm (CI -0.02 to 0.07) in the FB group. Continuous migration of the tibial component was found for 1 MB UKA and 2 FB UKAs. Both groups showed similar and clinically relevant improvement in clinical outcome. Interpretation - MB and FB tibial components had similar good fixation and clinical improvement until 2 years. Based on this study, a low 5- to 10-year revision rate can be expected for both implants.
引用
收藏
页码:575 / 581
页数:7
相关论文
共 37 条
[21]   Early recovery after fast-track Oxford unicompartmental knee arthroplasty 35 patients with minimal invasive surgery [J].
Munk, Stig ;
Dalsgaard, Jesper ;
Bjerggaard, Karin ;
Andersen, Ina ;
Hansen, Torben Baek ;
Kehlet, Henrik .
ACTA ORTHOPAEDICA, 2012, 83 (01) :41-45
[22]   Assessment of mobility after multi-level surgery for cerebral palsy [J].
Graham, H. K. ;
Harvey, A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (08) :993-994
[23]   The Oxford medial unicompartmental arthroplasty - A ten-year survival study [J].
Murray, DW ;
Goodfellow, JW ;
O'Connor, JJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (06) :983-989
[24]  
NJR, 2018, NAT JOINT REG ENGL W
[25]  
Odgaard A, 2009, TRANSLATION CROSS CU
[26]   The clinical outcome of minimally invasive Phase 3 Oxford unicompartmental knee arthroplasty A 15-YEAR FOLLOW-UP OF 1000 UKAS [J].
Pandit, H. ;
Hamilton, T. W. ;
Jenkins, C. ;
Mellon, S. J. ;
Dodd, C. A. F. ;
Murray, D. W. .
BONE & JOINT JOURNAL, 2015, 97B (11) :1493-1500
[27]   Minimally invasive Oxford phase 3 unicompartmental knee replacement RESULTS OF 1000 CASES [J].
Pandit, H. ;
Jenkins, C. ;
Gill, H. S. ;
Barker, K. ;
Dodd, C. A. F. ;
Murray, D. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (02) :198-204
[28]   Fixed- versus mobile-bearing UKA: a systematic review and meta-analysis [J].
Peersman, Geert ;
Stuyts, Bart ;
Vandenlangenbergh, Tom ;
Cartier, Philippe ;
Fennema, Peter .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (11) :3296-3305
[29]   Differences in long-term fixation between mobile-bearing and fixed-bearing knee prostheses at ten to 12 years' follow-up A SINGLE-BLINDED RANDOMISED CONTROLLED RADIOSTEREOMETRIC TRIAL [J].
Pijls, B. G. ;
Valstar, E. R. ;
Kaptein, B. L. ;
Nelissen, R. G. H. H. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (10) :1366-1371
[30]  
Pijls B G., Acta Orthop, DOI [10.1080/17453674.2018.1443635, DOI 10.1080/17453674.2018.1443635]