Automatic air temperature control in a container with an optic-variable wall

被引:9
作者
Wang, C. [1 ]
Zhu, Y. [2 ]
Qu, J. [3 ]
Hu, H. D. [1 ]
机构
[1] Changzhou Univ, Jiangsu Prov Key Lab Oil & Gas Storage & Transpor, Changzhou 213016, Jiangsu, Peoples R China
[2] Changzhou Univ, Jiangsu Prov Key Lab Fine Petrochem Engn, Changzhou 213164, Jiangsu, Peoples R China
[3] Jiangsu Univ, Sch Energy & Power Engn, Zhenjiang 21203, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar energy; Optic-variable wall (OVW); Air temperature control; Energy-saving; PASSIVE SOLAR HOUSE; THERMAL PERFORMANCE; ENERGY-STORAGE; INSULATION MATERIALS; REFLECTIVE COATINGS; TROMBE WALL; BUILDINGS; SIMULATION; SYSTEMS; VENTILATION;
D O I
10.1016/j.apenergy.2018.05.018
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solar energy is one important source of sustainable and green energy. However, solar radiation is not always demanded as heat source for building in seasons. Automatic air temperature control with an optic-variable wall is proposed in this paper to reduce the HVAC (Heating, Ventilation & Air-Conditioning) energy consumption in containers. The feasibility of an optic-variable wall (OVW) is first verified with sample-test on the color, reflectivity and absorbance with UV 3600. The reference for relectivity test is BaSO4 and the reference for absorbance test is quartz. The feasibility of its performance on air temperature control inside a container is verified with preliminary experiments under natural winter conditions at a low ambient temperature. It is checked that the color of OVW varies from dark at low temperature to light at high temperature. The reflectivity of OVW is small at low temperature and high at high temperature. Then, the theoretical investigation on air temperature inside a container is conducted. It is concluded that air inside a container is simultaneously kept cool in summer and warm in winter, with the adoption of OVW. The stable air temperature rise is small under the conditions of high ambient temperature and large solar radiation, leading to the potential of less energy consumption for cooling in summer, while it is large under the conditions of low ambient temperature and small solar radiation, leading to the potential of less energy consumption for heating in winter. The variation range of the stable air temperature with OVW is also narrower. The results are helpful for green design and energy saving in containers.
引用
收藏
页码:671 / 681
页数:11
相关论文
共 55 条
[51]   New concepts and approach for developing energy efficient buildings: Ideal specific heat for building internal thermal mass [J].
Zeng, Ruolang ;
Wang, Xin ;
Di, Hongfa ;
Jiang, Feng ;
Zhang, Yinping .
ENERGY AND BUILDINGS, 2011, 43 (05) :1081-1090
[52]   Numerical simulation investigation on thermal performance of heat pipe flat-plate solar collector [J].
Zhang, Dongwei ;
Tao, Hanzhong ;
Wang, Mimi ;
Sun, Zishuai ;
Jiang, Chuan .
APPLIED THERMAL ENGINEERING, 2017, 118 :113-126
[53]   Efficient planar perovskite solar cells based on high-quality perovskite films with smooth surface and large crystal grains fabricated in ambient air conditions [J].
Zhang, Lei ;
Zhang, Xuezhen ;
Yu, Yang ;
Xu, Xiaoxia ;
Tang, Jie ;
He, Xin ;
Wu, Jihuai ;
Lan, Zhang .
SOLAR ENERGY, 2017, 155 :942-950
[54]   Experimental study on thermal response of passive solar house with color changed [J].
Zhu, Jiayin ;
Chen, Bin .
RENEWABLE ENERGY, 2015, 73 :55-61
[55]   Simplified analysis methods for thermal responsive performance of passive solar house in cold area of China [J].
Zhu, Jiayin ;
Chen, Bin .
ENERGY AND BUILDINGS, 2013, 67 :445-452