Radiopacity of dental materials using a digital X-ray system

被引:71
作者
Gu, Steven [1 ]
Rasimick, Brian J. [1 ]
Deutsch, Allan S. [1 ]
Musikant, Barry Lee [1 ]
机构
[1] Essential Dent Labs, S Hackensack, NJ 07606 USA
关键词
radiopacity; radio-opacity digital radiography; step wedge of aluminum; target distance; Beer's law;
D O I
10.1016/j.dental.2005.11.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Radiopacity is a desirable property for most intra-oral materials. There are established ISO and ANSI/ADA protocols for determining radiopacity using film-based radiography. However, these methods are not always followed by researchers. This study aims to adapt those procedures by using digital radiography, a simplified stepwedge, and examine the effects of target distance and exposure time choice. Methods. One millimetre thick samples of three dental materials were prepared by placing the materials into a 1.00 mm thick washer sandwiched between two glass slides. The samples were digitally radiographed alongside a stepwedge of aluminum alloy 1100 with an X-ray unit at 70 kVp using five different target distance/exposure time combinations. For each combination, the grey scale values of various thicknesses of the stepwedge were converted into absorbencies and plotted against their thickness. These plots were then linearly regressed in order to correlate absorbance with a thickness of aluminum for each target distance/exposure time combination. The absorbencies of each sample were then converted into radiopacities using these correlations. Results. The correlations between the absorbance of the stepwedge and its thickness were highly linear. This linearity allows the correlation to be accurately deduced from fewer data points than required by the ISO and ANSI/ADA protocols. Varying exposure time did not significantly affect the mean radiopacity measured at a target distance of 30 cm. Varying the target distance did not significantly affect the measured radiopacity as long as the samples were properly exposed. Significance. A simplified, consistent digital method for determining radiopacity is presented. (C) 2005 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:765 / 770
页数:6
相关论文
共 16 条
[1]  
*AM HLTH, ENC MED IM, V1
[2]  
[Anonymous], 2000, 57 ANSIADA
[3]  
*ANSI ADA, 2000, 78 ANSIADA
[4]   RADIOPACITY OF ROOT-CANAL SEALERS [J].
BEYEROLSEN, EM ;
ORSTAVIK, D .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1981, 51 (03) :320-328
[5]   Evaluation of periapical lesion healing by correction of gray values [J].
Camps, J ;
Pommel, L ;
Bukiet, F .
JOURNAL OF ENDODONTICS, 2004, 30 (11) :762-766
[7]   THEORETICAL FORM-FACTOR, ATTENUATION AND SCATTERING TABULATION FOR Z=1-92 FROM E=1-10 EV TO E=0.4-1.0 MEV [J].
CHANTLER, CT .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1995, 24 (01) :71-591
[8]  
International Organization for Standardization, 2001, 6876 ISO
[9]  
*ISO, 1995, 6877 ISO
[10]  
ISODentistry, 2000, ISO 4049, V4049, P1