Monitoring, control and reduction of bioaerosols in the intensive care unit in Turkey

被引:0
作者
Lakestani, Sanaz [1 ]
Cakir, Ibrahim [1 ]
Gozdas, Hasan Tahsin [2 ]
Yildiz, Isa [3 ]
Demirhan, Abdullah [3 ]
机构
[1] Abant Izzet Baysal Univ, Sci Ind & Technol Applicat & Res Ctr, Bolu, Turkey
[2] Abant Izzet Baysal Univ, Fac Med, Dept Infect Dis, Bolu, Turkey
[3] Abant Izzet Baysal Univ, Fac Med, Dept Anesthesiol & Reanimat, Bolu, Turkey
关键词
air disinfection devices; bioaerosols; health & safety; indoor air; intensive care unit; matrix-assisted laser desorption; ionisation-time of flight mass spectrometry; monitoring; MORAXELLA-OSLOENSIS; AIR; CONTAMINATION; INFECTION;
D O I
10.1680/jenes.22.00002
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Maintaining high indoor air quality in hospitals is important for protecting the health of both personnel and patients. In this study, the results of air quality monitoring carried out in the intensive care unit of a hospital in Bolu, Turkey, are discussed. Air disinfection devices were used to reduce the concentrations of bacteria. A 4-week sampling programme was implemented. In the first and the last weeks of the sampling, the disinfection devices were turned off, while in the second and third weeks, they were turned on. Bioaerosols were collected, and their indoor levels were determined by counting all plate colonies and bacterial types were identified by matrix-assisted laser desorption/ionisation-time of flight mass spectrometry. The highest levels of bacteria were measured in the mornings and before the air disinfection devices were turned on. Doctors did their rounds at approximately nine to ten o'clock. The dominant bacteria in the air samples examined were Staphylococcus hominis, Micrococcus luteus, Staphylococcus capitis, Staphylococcus epidermidis, Corynebacterium afermentans and Staphylococcus haemolyticus. The results showed that the air disinfection devices were effective in decreasing the concentration of microorganisms between 83.4 and 55% in the intensive care unit, which is very important for the healthcare staff and patients, particularly during pandemics.
引用
收藏
页码:94 / 100
页数:7
相关论文
共 41 条
  • [21] Lakestani S., 2013, J CIVIL ENV STRUCT C, V7, P275, DOI [10.5281/zenodo.1061557, DOI 10.5281/ZENODO.1061557]
  • [22] Efficacy of indoor air purification in the treatment of Artemisia pollen-allergic rhinitis: A randomised, double-blind, clinical controlled trial
    Li, Li
    Zhang, Li
    Mo, Jin-Han
    Li, Yun-Ying
    Xia, Ji-Yan
    Bai, Xiao-Bing
    Xie, Pei-Fang
    Liang, Jing-Yi
    Yang, Zi-Feng
    Chen, Qiao-Yan
    [J]. CLINICAL OTOLARYNGOLOGY, 2020, 45 (03) : 394 - 401
  • [23] Microbial diversity in bioaerosol samples causing ODTS compared to reference bioaerosol samples as measured using Illumina sequencing and MALDI-TOF
    Madsen, Anne Mette
    Zervas, Athanasios
    Tendal, Kira
    Nielsen, Jeppe Lund
    [J]. ENVIRONMENTAL RESEARCH, 2015, 140 : 255 - 267
  • [24] Mandal J., 2011, Open Environmental & Biological Monitoring Journal, V4, P83, DOI 10.2174/1875040001104010083
  • [25] Mathema B., 2009, Staphylococci in human disease, V2nd
  • [26] Niazi S., 2009, Handbook of pharmaceutical manufacturing formulations, V2nd
  • [27] Ogun E., 2017, P 2017 ULUSAL TESISA, P1591
  • [28] The index of microbial air contamination
    Pasquarella, C
    Pitzurra, O
    Savino, A
    [J]. JOURNAL OF HOSPITAL INFECTION, 2000, 46 (04) : 241 - 256
  • [29] Acinetobacter lwoffii: Bacteremia associated with acute gastroenteritis
    Regalado, Nora G.
    Martin, Greg
    Antony, Suresh J.
    [J]. TRAVEL MEDICINE AND INFECTIOUS DISEASE, 2009, 7 (05) : 316 - 317
  • [30] Schleibinger H, 2004, HANDB ENVIRON CHEM, V4, P149, DOI 10.1007/b94834