Ring artifacts removal in X-ray-induced acoustic computed tomography

被引:0
|
作者
Pandey, Prabodh Kumar [1 ]
Aggrawal, Hari Om [2 ,3 ]
Wang, Siqi [4 ]
Kim, Kaitlyn [4 ]
Liu, An [5 ]
Xiang, Liangzhong [1 ,4 ,6 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
[2] Univ Lubeck, Inst Math & Image Comp, Lubeck, Germany
[3] Independent Tech Consultant, Delhi, India
[4] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92617 USA
[5] City Hope Natl Med Ctr, Dept Radiat Oncol, Duarte, CA 91010 USA
[6] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92612 USA
基金
美国国家卫生研究院;
关键词
X-ray-induced acoustic computed tomography (XACT); ring artifacts; artifacts correction; FEASIBILITY; SIMULATION; REDUCTION; WAVES; ARRAY;
D O I
10.1142/S1793545822500171
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray-induced acoustic computed tomography (XACT) is a hybrid imaging modality for detecting X-ray absorption distribution via ultrasound emission. It facilitates imaging from a single projection X-ray illumination, thus reducing the radiation exposure and improving imaging speed. Nonuniform detector response caused by the interference between multichannel data acquisition for ring array transducers and amplifier systems yields ring artifacts in the reconstructed XACT images, which compromises the image quality. We propose model-based algorithms for ring artifacts corrected XACT imaging and demonstrate their efficacy on numerical and experimental measurements. The corrected reconstructions indicate significantly reduced ring artifacts as compared to their conventional counterparts.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Fast X-Ray-Induced Acoustic Computed Tomography
    Faiz, R.
    Tang, S.
    Zheng, B.
    Liu, H.
    Zarafshani, A.
    Xiang, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3253 - 3253
  • [2] X-Ray-Induced Acoustic Computed Tomography for Osteoporosis
    Li, Y.
    Samant, P.
    Wang, S.
    Xianghu
    Liu, Hong
    Yu, Aixi
    Xiang, Liangzhong
    MEDICAL PHYSICS, 2019, 46 (06) : E668 - E669
  • [3] X-ray-induced acoustic computed tomography with an ultrasound transducer ring-array
    Tang, S.
    Nguyen, D. H.
    Zarafshani, A.
    Ramseyer, C.
    Zheng, B.
    Liu, H.
    Xiang, L.
    APPLIED PHYSICS LETTERS, 2017, 110 (10)
  • [4] Effects of Acoustic Heterogeneity in X-Ray-Induced Acoustic Computed Tomography
    Cochran, C.
    Samant, P.
    Xiang, L.
    MEDICAL PHYSICS, 2019, 46 (06) : E134 - E134
  • [5] X-ray-induced acoustic computed tomography of concrete infrastructure
    Tang, Shanshan
    Ramseyer, Chris
    Samant, Pratik
    Xiang, Liangzhong
    APPLIED PHYSICS LETTERS, 2018, 112 (06)
  • [6] Model-Based X-Ray-Induced Acoustic Computed Tomography
    Pandey, Prabodh Kumar
    Wang, Siqi
    Aggrawal, Hari Om
    Bjegovic, Kristina
    Boucher, Salime
    Xiang, Liangzhong
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (12) : 3560 - 3569
  • [7] X-ray-induced acoustic computed tomography and its applications in biomedicine
    Yan, Yuchen
    Xiang, Shawn
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29
  • [8] Dose Images Reconstruction Based on X-ray-Induced Acoustic Computed Tomography
    Liu, Yanhua
    Liu, Mingzhe
    Jiang, Xin
    Liu, Xianghe
    Liu, Min
    ELECTRONICS, 2023, 12 (10)
  • [9] X-Ray-Induced Acoustic Computed Tomography (XACT): Initial Experiment on Bone Sample
    Robertson, Elijah
    Samant, Pratik
    Wang, Siqi
    Tran, Tiffany
    Ji, Xuanrong
    Xiang, Liangzhong
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (04) : 1073 - 1080
  • [10] RING ARTIFACTS IN X-RAY COMPUTED-TOMOGRAPHY
    CRANAGE, RW
    TOFTS, PS