Preparation of alumina-coated magnetite nanoparticle for extraction of trimethoprim from environmental water samples based on mixed hemimicelles solid-phase extraction

被引:136
作者
Sun, Lei [1 ]
Zhang, Chuanzhou [2 ]
Chen, Ligang [1 ]
Liu, Jun [1 ]
Jin, Haiyan [1 ]
Xu, Haoyan [1 ]
Ding, Lan [1 ]
机构
[1] Jilin Univ, Coll Chem, Changchun 130012, Peoples R China
[2] Jilin Prov Prod Qual Supervis Test Inst, Changchun 130022, Peoples R China
基金
中国国家自然科学基金;
关键词
Alumina-coated magnetite nanoparticles; Mixed hemimicelles; Solid-phase extraction; Trimethoprim; Environmental water samples; WASTE-WATER; BENZALKONIUM SURFACTANTS; PHENOLIC-COMPOUNDS; RIVER WATER; LIQUID; ANTIBIOTICS; SULFONAMIDE; SEWAGE; HPLC; SULFAMETHOXAZOLE;
D O I
10.1016/j.aca.2009.02.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a new type of alumina-coated magnetite nanoparticles (Fe3O4/Al2O3 NPs) modified by the surfactant sodium dodecyl sulfate (SDS) has been successfully synthesized and applied for extraction of trimethoprim (TMP) from environmental water samples based on mixed hemimicelles solid-phase extraction (MHSPE). The coating of alumina on Fe3O4 NPs not only avoids the dissolving of Fe3O4 NPs in acidic solution, but also extends their application without sacrificing their unique magnetization characteristics. Due to the high surface area of these new sorbents and the excellent adsorption capacity after surface modification by SDS, satisfactory concentration factor and extraction recoveries can be produced with only 0.1 g Fe3O4/Al2O3 NPs. Main factors affecting the adsolubilization of TMP such as the amount of SDS. pH value, standing time, desorption solvent and maximal extraction volume were optimized. Under the selected conditions, TMP could be quantitatively extracted. The recoveries of TMP by analyzing the four spiked water samples were between 67 and 86%, and the relative standard deviation (RSD) ranged from 2 to 6%. Detection and quantification limits of the proposed method were 0.09 and 0.24 mu g L-1, respectively. Concentration factor of 1000 was achieved using this method to extract 500 mL of different environmental water samples. Compared with conventional SPE methods, the advantages of this new Fe3O4/Al2O3 NPs MHSPE method still include easy preparation and regeneration of sorbents, short times of sample pretreatment, high extraction yields, and high breakthrough Volumes. It shows great analytical potential in preconcentration of organic compounds from large volume water samples. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:162 / 168
页数:7
相关论文
共 32 条
[1]   Solid phase extraction and HPLC determination of veterinary pharmaceuticals in wastewater [J].
Babic, Sandra ;
Asperger, Danijela ;
Mutavdzic, Dragana ;
Horvat, Alka J. M. ;
Kastelan-Macan, Marija .
TALANTA, 2006, 70 (04) :732-738
[2]   Simultaneous determination of sulfamethoxazole and trimethoprim in biological fluids for high-throughput analysis:: Comparison of HPLC with ultraviolet and tandem mass spectrometric detection [J].
Bedor, D. C. G. ;
Goncalves, T. M. ;
Ferreiraa, M. L. L. ;
de Sousaa, C. E. M. ;
Menezes, A. L. ;
Oliveira, E. J. ;
de Santana, D. P. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 863 (01) :46-54
[3]   Determination of non-ionic polyethoxylated surfactants in wastewater and river water by mixed hemimicelle extraction and liquid chromatography-ion trap mass spectrometry [J].
Cantero, M ;
Rubio, S ;
Pérez-Bendito, D .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1067 (1-2) :161-170
[4]   Determination of alkylphenols and alkylphenol carboxylates in wastewater and river samples by hemimicelle-based extraction and liquid chromatography-ion trap mass spectrometry [J].
Cantero, Manuel ;
Rubio, Soledad ;
Perez-Bendito, Dolores .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1120 (1-2) :260-267
[5]   Simultaneous analysis of 16 sulfonamide and trimethoprim antibiotics in environmental waters by liquid chromatography-electrospray tandem mass spectrometry [J].
Chang, Hong ;
Hu, Jianying ;
Asami, Mari ;
Kunikane, Shoichi .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1190 (1-2) :390-393
[6]   Comparison of a liquid chromatographic method with ultraviolet and ion-trap tandem mass spectrometric detection for the simultaneous determination of sulfadiazine and trimethoprim in plasma from dogs [J].
Croubels, S ;
De Baere, S ;
De Backer, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (01) :167-178
[7]   Simultaneous quantification of sulfamethoxazole and trimethoprim in whole egg samples by column-switching high-performance liquid chromatography using restricted access media column for on-line sample clean-up [J].
de Paula, F. C. C. R. ;
de Pietro, A. C. ;
Cass, Q. B. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) :221-226
[8]   Extraction and determination of sulfonamides, macrolides, and trimethoprim in sewage sludge [J].
Göbel, A ;
Thomsen, A ;
McArdell, CS ;
Alder, AC ;
Giger, W ;
Theiss, N ;
Löffler, D ;
Ternes, TA .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1085 (02) :179-189
[9]   Trace determination of macrolide and sulfonamide antimicrobials, a human sulfonamide metabolite, and trimethoprim in wastewater using liquid chromatography coupled to electrospray tandem mass spectrometry [J].
Göbel, A ;
McArdell, CS ;
Suter, MJF ;
Giger, W .
ANALYTICAL CHEMISTRY, 2004, 76 (16) :4756-4764
[10]   Improved properties of magnetic particles by combination of different polymer materials as particle matrix [J].
Grüttner, C ;
Rudershausen, S ;
Teller, J .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2001, 225 (1-2) :1-7