Intrapartum cardiotocogram monitoring between obstetricians and computer analysis

被引:5
|
作者
Magawa, Shoichi [1 ]
Tanaka, Hiroaki [1 ]
Furuhashi, Fumi [1 ]
Maki, Shintaro [1 ]
Nii, Masafumi [1 ]
Toriyabe, Kuniaki [1 ]
Kondo, Eiji [1 ]
Ikeda, Tomoaki [1 ]
机构
[1] Mie Univ, Fac Med, Dept Obstet & Gynecol, 2-174 Edobashi, Tsu, Mie, Japan
关键词
Cardiotocogram (CTG) monitoring; computer analysis; deceleration; fetal heart rate; Trium; DEVELOPMENT WORKSHOP REPORT; FETAL; CLASSIFICATION; DEFINITIONS; GUIDELINES; UPDATE;
D O I
10.1080/14767058.2019.1617688
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Purpose: To investigate the accuracy of computer analysis and its features to be used as a fu fetal heart rate (FHR) interpretation method in clinical settings. Methods: The Trium CTG Online (R) was used as the computer analysis software. Twenty-six cases of intrapartum FHR tracings (total time, 6900 min) were randomly selected from third-trimester pregnancies. Three obstetricians blinded to the patients' clinical information traced the decelerations, variability, and baseline cardiotocogram (CTG) data. Three obstetrician observer individually interpreted the data and only the waveforms they interpreted were adopted. The agreement between the deceleration and baseline, variability, and level of five-tier system was estimated. Weighted kappa (kappa) statistics were used to assess reliability. Results: Based on the observers and Trium's classification, kappa was 0.78 and the strength of agreement level was substantial. The obstetricians and Trium mostly agreed on the variability and baseline data. However, kappa of each deceleration was approximately 0.65 (0.63-0.66), with substantial strength of agreement. Conclusion: Based on the obstetricians and Trium's interpretation, the latter was found to be excellent for FHR interpretation. However, it was difficult for Trium to interpret specific waveform patterns. Therefore, clinical staff should understand these characteristics to more sensitively evaluate the fetal well-being.
引用
收藏
页码:787 / 793
页数:7
相关论文
共 50 条
  • [31] Fetal electrocardiography ST-segment analysis for intrapartum monitoring: a critical appraisal of conflicting evidence and a way forward
    Amer-Wahlin, Isis
    Ugwumadu, Austin
    Yli, Branka M.
    Kwee, Anneke
    Timonen, Susanna
    Cole, Vanessa
    Ayres-de-Campos, Diogo
    Roth, Georges-Emmanuel
    Schwarz, Christiane
    Ramenghi, Luca A.
    Todros, Tullia
    Ehlinger, Virginie
    Vayssiere, Christophe
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2019, 221 (06) : 577 - +
  • [32] Challenges of Developing Robust AI for Intrapartum Fetal Heart Rate Monitoring
    O'Sullivan, M. E.
    Considine, E. C.
    O'Riordan, M.
    Marnane, W. P.
    Rennie, J. M.
    Boylan, G. B.
    FRONTIERS IN ARTIFICIAL INTELLIGENCE, 2021, 4
  • [33] Intrapartum cardiotocograph monitoring and perinatal outcomes for women at risk: Literature review
    Small, Kirsten A.
    Sidebotham, Mary
    Fenwick, Jennifer
    Gamble, Jenny
    WOMEN AND BIRTH, 2020, 33 (05) : 411 - 418
  • [34] Comparison of the effect of different sampling modes on computer analysis of cardiotocograms
    Goncalves, Hernani
    Chaves, Joana
    Costa, Antonia
    Ayres-de-Campos, Diogo
    Bernardes, Joao
    COMPUTERS IN BIOLOGY AND MEDICINE, 2015, 64 : 62 - 66
  • [35] Automatic evaluation of intrapartum fetal heart rate recordings: a comprehensive analysis of useful features
    Chudacek, V.
    Spilka, J.
    Janku, P.
    Koucky, M.
    Lhotska, L.
    Huptych, M.
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (08) : 1347 - 1360
  • [36] Delphi consensus statement on intrapartum fetal monitoring in low-resource settings
    Housseine, Natasha
    Punt, Marieke C.
    Browne, Joyce L.
    Van't Hooft, Janneke
    Maaloe, Nanna
    Meguid, Tarek
    Theron, Gerhard B.
    Franx, Arie
    Grobbee, Diederick E.
    Visser, Gerard H. A.
    Rijken, Marcus J.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2019, 146 (01) : 8 - 16
  • [37] Reliability and agreement in intrapartum fetal heart rate monitoring interpretation: A systematic review
    Engelhart, Christina Hernandez
    Brurberg, Kjetil Gundro
    Aanstad, Kristin Jerve
    Pay, Aase Serine Devold
    Kaasen, Anne
    Blix, Ellen
    Vanbelle, Sophie
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2023, 102 (08) : 970 - 985
  • [38] Fetal electrocardiogram:: ST waveform analysis in intrapartum surveillance
    Amer-Wahlin, I.
    Arulkumaran, S.
    Hagberg, H.
    Marsal, K.
    Visser, G. H. A.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2007, 114 (10) : 1191 - 1193
  • [39] MULTIFRACTAL ANALYSIS OF ECG FOR INTRAPARTUM DIAGNOSIS OF FETAL ASPHYXIA
    Abry, P.
    Helgason, H.
    Goncalves, P.
    Pereira, E.
    Gaucherand, P.
    Doret, M.
    2010 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2010, : 566 - 569
  • [40] Interobserver agreement in CTG interpretation using the 2015 FIGO guidelines for intrapartum fetal monitoring
    Rei, Mariana
    Tavares, Sara
    Pinto, Pedro
    Machado, Ana P.
    Monteiro, Sofia
    Costa, Antonia
    Costa-Santos, Cristina
    Bernardes, Joao
    Ayres-De-Campos, Diogo
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2016, 205 : 27 - 31