Local and global subaxial cervical spine biomechanics after single-level fusion or cervical arthroplasty

被引:96
作者
Finn, Michael A. [2 ]
Brodke, Darrel S. [1 ]
Daubs, Michael [1 ]
Patel, Alpesh [1 ]
Bachus, Kent N. [3 ]
机构
[1] Univ Utah, Univ Orthopaed Ctr, Dept Orthoped Surg, Salt Lake City, UT 84108 USA
[2] Univ Utah, Sch Med, Dept Neurosurg, Salt Lake City, UT 84108 USA
[3] Univ Utah, Sch Med, Orthopaed Bioengn Lab, Salt Lake City, UT 84108 USA
关键词
Cervical arthroplasty; Biomechanics; Subaxial spine; Fusion; INTERVERTEBRAL-DISK; INTRADISCAL PRESSURE; SOLUTE TRANSPORT; INTERBODY FUSION; FOLLOW-UP; IN-VIVO; ADJACENT; JOINT; DISEASE; PROSTHESIS;
D O I
10.1007/s00586-009-1085-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
An experimental in vitro biomechanical study was conducted on human cadaveric spines to evaluate the motion segment (C4-C5) and global subaxial cervical spine motion after placement of a cervical arthroplasty device (Altia TDI (TM), Amedica, Salt Lake City, UT) as compared to both the intact spine and a single-level fusion. Six specimens (C2-C7) were tested in flexion/extension, lateral bending, and axial rotation under a +/- 1.5 Nm moment with a 100 N axial follower load. Following the intact spine was tested; the cervical arthroplasty device was implanted at C4-C5 and tested. Then, a fusion using lateral mass fixation and an anterior plate was simulated and tested. Stiffness and range of motion (ROM) data were calculated. The ROM of the C4-C5 motion segment with the arthroplasty device was similar to that of the intact spine in flexion/extension and slightly less in lateral bending and rotation, while the fusion construct allowed significantly less motion in all directions. The fusion construct caused broader effects of increasing motion in the remaining segments of the subaxial cervical spine, whereas the TDI did not alter the adjacent and remote motion segments. The fusion construct was also far stiffer in all motion planes than the intact motion segment and the TDI, while the artificial disc treated level was slightly stiffer than the intact segment. The Altia TDI allows for a magnitude of motion similar to that of the intact spine at the treated and adjacent levels in the in vitro setting.
引用
收藏
页码:1520 / 1527
页数:8
相关论文
共 36 条
[1]   Dislocations with intervertebral disc prosthesis: two case reports [J].
Aunoble, S ;
Donkersloot, P ;
Le Huec, JC .
EUROPEAN SPINE JOURNAL, 2004, 13 (05) :464-467
[2]  
Azmi Hooman, 2003, Neurosurg Focus, V15, pE6
[3]   LATE RADIOGRAPHIC FINDINGS AFTER ANTERIOR CERVICAL FUSION FOR SPONDYLOTIC MYELORADICULOPATHY [J].
BABA, H ;
FURUSAWA, N ;
IMURA, S ;
KAWAHARA, N ;
TSUCHIYA, H ;
TOMITA, K .
SPINE, 1993, 18 (15) :2167-2173
[4]   Early results after ProDisc-C cervical disc replacement [J].
Bertagnoli, R ;
Yue, JJ ;
Pfeiffer, F ;
Fenk-Mayer, A ;
Lawrence, JP ;
Kershaw, T ;
Nanieva, R .
JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (04) :403-410
[5]   BIOMECHANICS OF THE SB CHARITE LUMBAR INTERVERTEBRAL-DISK ENDOPROSTHESIS [J].
BUTTNERJANZ, K ;
SCHELLNACK, K ;
ZIPPEL, H .
INTERNATIONAL ORTHOPAEDICS, 1989, 13 (03) :173-176
[6]  
CHERUBINO P, 1990, Italian Journal of Orthopaedics and Traumatology, V16, P533
[7]   THE ANTERIOR APPROACH FOR REMOVAL OF RUPTURED CERVICAL DISKS [J].
CLOWARD, RB .
JOURNAL OF NEUROSURGERY, 1958, 15 (06) :602-617
[8]   Prospective randomized controlled study of the Bryan Cervical Disc: early clinical results from a single investigational site - Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005 [J].
Coric, D ;
Finger, F ;
Boltes, P .
JOURNAL OF NEUROSURGERY-SPINE, 2006, 4 (01) :31-35
[9]   Surgical experience with an implanted artificial cervical joint [J].
Cummins, BH ;
Robertson, JT ;
Gill, SS .
JOURNAL OF NEUROSURGERY, 1998, 88 (06) :943-948
[10]   Revision of a Charite artificial disc 9.5 years in vivo to a new Charite artificial disc: case report and explant analysis [J].
David, T .