Analysis of Samples Stored as Individual Plugs in a Capillary by Electrospray Ionization Mass Spectrometry

被引:76
|
作者
Pei, Jian [1 ]
Li, Qiang [1 ]
Lee, Mike S. [3 ]
Valaskovic, Gary A. [4 ]
Kennedy, Robert T. [1 ,2 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Pharmacol, Ann Arbor, MI 48109 USA
[3] Milestone Dev Serv Inc, Milestone Dev Serv, Newtown, PA 18940 USA
[4] New Object Inc, Cambridge, MA 02139 USA
关键词
MICROFLUIDIC DEVICES; AQUEOUS DROPLETS; NANOLITER PLUGS; FLOW-ANALYSIS; SYSTEM; TIME; NANOPARTICLES; MANIPULATION; CARTRIDGES; REAGENTS;
D O I
10.1021/ac901172a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Droplets or plugs within multiphase microfluidic systems have rapidly gained interest as a way to manipulate samples and chemical reactions on the femtoliter to microliter scale. Chemical analysis of the plugs remains a challenge. We have discovered that nanoliter plugs of sample separated by air or oil can be analyzed by electrospray ionization mass spectrometry when pumped directly into a fused silica nanospray emitter tip. Using leucine-enkephalin in methanol and 1% acetic acid in water (50:50 v:v) as a model sample, we found carry-over between plugs was < 0.1% and relative standard deviation of signal for a series of plugs was 3%. Detection limits were 1 nM. Sample analysis rates of 0.8 Hz were achieved by pumping 13 nL samples separated by 3 mm long air gaps in a 75 mu m inner diameter tube. Analysis rates were limited by the scan time of the ion trap mass spectrometer. The system provides a robust, rapid, and information-rich method for chemical analysis of sample in segmented flow systems.
引用
收藏
页码:6558 / 6561
页数:4
相关论文
共 50 条
  • [21] Processed eggshell as sample carrier for rapid analysis of organometallic compounds by desorption electrospray ionization mass spectrometry
    Zhu, Wei
    Wang, Hao-Yang
    Zhang, Junting
    Zhang, Shusheng
    Guo, Yinlong
    JOURNAL OF MASS SPECTROMETRY, 2015, 50 (08): : 972 - 977
  • [22] Controlling Charge States of Peptides through Inductive Electrospray Ionization Mass Spectrometry
    Peng, Yue'e
    Zhang, Sichun
    Gong, Xiaoyun
    Ma, Xiaoxiao
    Yang, Chengdui
    Zhang, Xinrong
    ANALYTICAL CHEMISTRY, 2011, 83 (23) : 8863 - 8866
  • [23] Secondary electrospray ionization-mass spectrometry: breath study on a control group
    Martinez-Lozano, P.
    Zingaro, L.
    Finiguerra, A.
    Cristoni, S.
    JOURNAL OF BREATH RESEARCH, 2011, 5 (01)
  • [24] Reactive Charged Droplets for Reduction of Matrix Effects in Electrospray Ionization Mass Spectrometry
    Kulyk, Dmytro S.
    Miller, Colbert F.
    Badu-Tawiah, Abraham K.
    ANALYTICAL CHEMISTRY, 2015, 87 (21) : 10988 - 10994
  • [25] Capillary Zone Electrophoresis-Electrospray Ionization-Tandem Mass Spectrometry for Top-Down Characterization of the Mycobacterium marinum Secretome
    Zhao, Yimeng
    Sun, Liangliang
    Champion, Matthew M.
    Knierman, Michael D.
    Dovichi, Norman J.
    ANALYTICAL CHEMISTRY, 2014, 86 (10) : 4873 - 4878
  • [26] Ultra-Low Flow Electrospray Ionization-Mass Spectrometry for Improved Ionization Efficiency in Phosphoproteomics
    Heemskerk, Anthonius A. M.
    Busnel, Jean-Marc
    Schoenmaker, Bart
    Derks, Rico J. E.
    Klychnikov, Oleg
    Hensbergen, Paul J.
    Deelder, Andre M.
    Mayboroda, Oleg A.
    ANALYTICAL CHEMISTRY, 2012, 84 (10) : 4552 - 4559
  • [27] Hyphenation of capillary high-performance ion-exchange chromatography with mass spectrometry using sheath-flow electrospray ionization
    Kochmann, Sven
    Matysik, Frank-Michael
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (23) : 2670 - 2680
  • [28] Fraction Collection from Capillary Liquid Chromatography and Off-line Electrospray Ionization Mass Spectrometry Using Oil Segmented Flow
    Li, Qiang
    Pei, Jian
    Song, Peng
    Kennedy, Robert T.
    ANALYTICAL CHEMISTRY, 2010, 82 (12) : 5260 - 5267
  • [29] In-spray supercharging of intact proteins by capillary electrophoresis-electrospray ionization-mass spectrometry using sheath liquid interface
    Bonvin, Gregoire
    Rudaz, Serge
    Schappler, Julie
    ANALYTICA CHIMICA ACTA, 2014, 813 : 97 - 105
  • [30] Analysis of secondary organic aerosols in air using extractive electrospray ionization mass spectrometry (EESI-MS)
    Doezema, Lambert A.
    Longin, Teresa
    Cody, William
    Perraud, Veronique
    Dawson, Matthew L.
    Ezell, Michael J.
    Greaves, John
    Johnson, Kathleen R.
    Finlayson-Pitts, Barbara J.
    RSC ADVANCES, 2012, 2 (07) : 2930 - 2938