Personalized glucose-insulin model based on signal analysis

被引:4
作者
Goede, Simon L. [1 ]
de Galan, Bastiaan E. [2 ]
Leow, Melvin Khee Shing [3 ,4 ]
机构
[1] Syst Res, Oterlekerweg 4, NL-1841 GP Stompetoren, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Gen Internal Med, Postbus 9101, NL-6500 HB Nijmegen, Netherlands
[3] Tan Tock Seng Hosp, Dept Endocrinol, Singapore 308433, Singapore
[4] Nanyang Technol Univ, Off Clin Sci, Duke NUS Grad Med Sch, Singapore Lee Kong Chian Sch Med, Singapore, Singapore
关键词
Appearance profile; Model identification; Electrical network model; Simulation; Personalized target; Validation;
D O I
10.1016/j.jtbi.2016.12.018
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Glucose plasma measurements for diabetes patients are generally presented as a glucose concentration-time profile with 15-60 min time scale intervals. This limited resolution obscures detailed dynamic events of glucose appearance and metabolism. Measurement intervals of 15 min or more could contribute to imperfections in present diabetes treatment. High resolution data from mixed meal tolerance tests (MMTT) for 24 type 1 and type 2 diabetes patients were used in our present modeling. We introduce a model based on the physiological properties of transport, storage and utilization. This logistic approach follows the principles of electrical network analysis and signal processing theory. The method mimics the physiological equivalent of the glucose homeostasis comprising the meal ingestion, absorption via the gastrointestinal tract (GIT) to the endocrine nexus between the liver, pancreatic alpha and beta cells. This model demystifies the metabolic 'black box' by enabling in silico simulations and fitting of individual responses to clinical data. Five-minute intervals MMIT data measured from diabetic subjects result in two independent model parameters that characterize the complete glucose system response at a personalized level. From the individual data measurements, we obtain a model which can be analyzed with a standard electrical network simulator for diagnostics and treatment optimization. The insulin dosing time scale can be accurately adjusted to match the individual requirements of characterized diabetic patients without the physical burden of treatment.
引用
收藏
页码:333 / 342
页数:10
相关论文
共 50 条
  • [21] A Brain-oriented Compartmental Model of Glucose-Insulin-Glucagon Regulatory System
    Lu Gaohua
    Kimura, Hidenori
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 1655 - +
  • [22] Analysis of signal integrity based on SPECCTRA Quest
    Wang, LA
    Zhou, RJ
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 6, 2005, : 211 - 214
  • [23] Acoustic Signal Recognition Based on Time Series Model
    Cui, Yuquan
    Shi, Lejun
    Fang, Yuwei
    MANUFACTURING PROCESS TECHNOLOGY, PTS 1-5, 2011, 189-193 : 3243 - +
  • [24] A rule-based model of insulin signalling pathway
    Di Camillo, Barbara
    Carlon, Azzurra
    Eduati, Federica
    Toffolo, Gianna Maria
    BMC SYSTEMS BIOLOGY, 2016, 10
  • [25] Modeling and Analysis of Sea-clutter Signal for Wide-band Radar Based on Electromagnetic Model
    Wang, Tong
    Chuangming, Tong
    Guangfei, X. U.
    Peng, Peng
    Yijin, Wang
    JOURNAL OF ELECTRONICS & INFORMATION TECHNOLOGY, 2022, 44 (04) : 1358 - 1365
  • [26] ReplayBG: A Digital Twin-Based Methodology to Identify a Personalized Model From Type 1 Diabetes Data and Simulate Glucose Concentrations to Assess Alternative Therapies
    Cappon, Giacomo
    Vettoretti, Martina
    Sparacino, Giovanni
    Favero, Simone Del
    Facchinetti, Andrea
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (11) : 3227 - 3238
  • [27] In vivo measurement of the rate constant of liver handling of glucose and glucose uptake by insulin-dependent tissues, using a mathematical model for glucose homeostasis in diabetic rats
    Lombarte, Mercedes
    Lupo, Maela
    Fina Brenda, L.
    Campetelli, German
    Buzalaf Marilia, A. R.
    Basualdo, Marta
    Rigalli, Alfredo
    JOURNAL OF THEORETICAL BIOLOGY, 2018, 439 : 205 - 215
  • [28] Blood glucose detection based on Teager-Kaiser main energy of photoacoustic signal
    Long, Hongfeng
    Chen, Bingzhang
    Li, Wei
    Xian, Yongli
    Peng, Zhenming
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 134
  • [29] A universal SPICE model for signal analysis of a straw tube detector
    Lan, Kejian A.
    Cui, Yonggong
    Hungerford, Ed V.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1191 - 1195
  • [30] Analysis on the Practical Identifiability of the Subcutaneous Oral Glucose Minimal Model
    Villa-Tamayo, Maria F.
    Pavan, Jacopo
    Breton, Marc
    IFAC PAPERSONLINE, 2024, 58 (24): : 269 - 274