摘要
Transplantation of macroencapsulated tissue-engineered grafts (TEGs) is being investigated as a treatment for type 1 diabetes, but there is a critical need to measure TEG viability both in vitro and in vivo. Oxygen deficiency is the most critical issue preventing widespread implementation of TEG transplantation and delivery of supplemental oxygen (DSO) has been shown to enhance TEG survival and function in vivo. In this study, we demonstrate the first use of oxygen-17 magnetic resonance spectroscopy (O-17-MRS) to measure the oxygen consumption rate (OCR) of TEGs and show that in addition to providing therapeutic benefits to TEGs, DSO with O-17(2) can also enable measurements of TEG viability. Macroencapsulated TEGs containing beta TC3 murine insulinoma cells were prepared with three fractional viabilities and provided with O-17(2). Cellular metabolism of O-17(2) into nascent mitochondrial water (H-2 O-17) was monitored by O-17-MRS and, from the measured data, OCR was calculated. For comparison, OCR was simultaneously measured on a separate, but equivalent sample of cells with a well-established stirred microchamber technique. OCR measured by O-17-MRS agreed well with measurements made in the stirred microchamber device. These studies confirm that O-17-MRS can quantify TEG viability noninvasively. (C) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:1118 / 1121
页数:4
相关论文
共 14 条
  • [1] Assessment of Tissue-Engineered Islet Graft Viability by Fluorine Magnetic Resonance Spectroscopy
    Suszynski, T. M.
    Avgoustiniatos, E. S.
    Stein, S. A.
    Falde, E. J.
    Hammer, B. E.
    Papas, K. K.
    TRANSPLANTATION PROCEEDINGS, 2011, 43 (09) : 3221 - 3225
  • [2] Development and Validation of Noninvasive Magnetic Resonance Relaxometry for the In Vivo Assessment of Tissue-Engineered Graft Oxygenation
    Einstein, Samuel A.
    Weegman, Bradley P.
    Firpo, Meri T.
    Papas, Klearchos K.
    Garwood, Michael
    TISSUE ENGINEERING PART C-METHODS, 2016, 22 (11) : 1009 - 1017
  • [3] Resorption rate assessment of adipose tissue-engineered constructs by intravital magnetic resonance imaging
    Torio-Padron, N.
    Paul, D.
    von Elverfeldt, D.
    Stark, G. B.
    Huotari, A. M.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2011, 64 (01) : 117 - 122
  • [4] Noninvasive Absolute Electron Paramagnetic Resonance Oxygen Imaging for the Assessment of Tissue Graft Oxygenation
    Kotecha, Mrignayani
    Epel, Boris
    Ravindran, Sriram
    Dorcemus, Deborah
    Nukavarapu, Syam
    Halpern, Howard
    TISSUE ENGINEERING PART C-METHODS, 2018, 24 (01) : 14 - 19
  • [5] Rapid, Quantitative Nuclear Magnetic Resonance Test for Oxygen-17 Enrichment in Water
    Peterson, Joshua W.
    Burt, Scott R.
    Yuan, Yu
    Harper, James K.
    ANALYTICAL CHEMISTRY, 2022, 94 (15) : 5741 - 5743
  • [6] The role of magnetic resonance spectroscopy in the assessment of kidney viability
    Barnard, ML
    Changani, KK
    TaylorRobinson, SD
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1997, 31 (05): : 487 - 492
  • [7] In Vivo Noninvasive Monitoring of Dissolved Oxygen Concentration Within an Implanted Tissue-Engineered Pancreatic Construct
    Goh, Fernie
    Sambanis, Athanassios
    TISSUE ENGINEERING PART C-METHODS, 2011, 17 (09) : 887 - 894
  • [8] Magnetic Resonance Imaging of Shear Stress and Wall Thickness in Tissue-Engineered Vascular Grafts
    Stacy, Mitchel R.
    Best, Cameron A.
    Maxfield, Mark W.
    Qiu, Maolin
    Naito, Yuji
    Kurobe, Hirotsugu
    Mahler, Nathan
    Rocco, Kevin A.
    Sinusas, Albert J.
    Shinoka, Toshiharu
    Sampath, Smita
    Breuer, Christopher K.
    TISSUE ENGINEERING PART C-METHODS, 2018, 24 (08) : 465 - 473
  • [9] Structural Role of Alkali Cations in Calcium Aluminosilicate Glasses as Examined Using Oxygen-17 Solid-State Nuclear Magnetic Resonance Spectroscopy
    Sukenaga, Sohei
    Kanehashi, Koji
    Shibata, Hiroyuki
    Saito, Noritaka
    Nakashima, Kunihiko
    METALLURGICAL AND MATERIALS TRANSACTIONS B-PROCESS METALLURGY AND MATERIALS PROCESSING SCIENCE, 2016, 47 (04): : 2177 - 2181
  • [10] Viability assessment of magnetic resonance spectroscopy for the detection of minimal hepatic encephalopathy severity
    Meng, Ling-ping
    Chen, Yuan-chang
    Li, Yue-hua
    Zhu, Jin-shui
    Ye, Jian-lin
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (10) : 2019 - 2023