Simultaneous determination of ultra-trace level 237Np and Pu isotopes in soil and sediment samples by SF-ICP-MS with a single column chromatographic separation

被引:35
作者
Huang, Zhaoya [1 ,2 ]
Ni, Youyi [3 ]
Wang, Hai [4 ]
Zheng, Jian [1 ]
Yamazaki, Shinnosuke [1 ]
Sakaguchi, Aya [5 ]
Long, Xinggui [2 ]
Uchida, Shigeo [1 ]
机构
[1] Natl Inst Quantum & Radiol Sci & Technol, Dept Radioecol & Fukushima Project, Inage Ku, 491 Anagawa, Chiba 2638555, Japan
[2] China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621900, Sichuan, Peoples R China
[3] Peking Univ, Sch Phys, State Key Lab Nucl Phys & Technol, Beijing 100871, Peoples R China
[4] Univ South China, Sch Nucl Sci & Technol, Hengyang 421001, Peoples R China
[5] Univ Tsukuba, Ctr Res Isotopes & Environm Dynam, Tsukuba, Ibaraki, Japan
关键词
Np-237; Pu isotope; Anion-exchange chromatography; SF-ICP-MS; Soil; ENVIRONMENTAL-SAMPLES; ATOMIC SPECTROMETRY; RAPID-DETERMINATION; PLUTONIUM; FIELD; RADIONUCLIDES; FOREST; AM-241; AM; NP;
D O I
10.1016/j.microc.2019.05.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents a method developed for simultaneous analysis of ultra-trace level Np-237 and Pu isotopes in soil and sediment samples by sector field inductively coupled plasma mass spectrometry (SF-ICP-MS). Pu-242 was used as a yield tracer for Np-237 as well as for Pu isotopes. A simple single chromatographic column packed with anion exchange resin (AG MP-1M) was used for the separation of Np-237 and Pu isotopes from the matrix elements and other potential interferences. The SF-ICP-MS measurement precision of the Np-237/Pu-242 atom ratio for sub-fg/mL level Np-237 and (PU)-P-242 was 0.97%, and the overall fractionation between Np-237 and (PU)-P-242 for the whole analysis procedure was 1.010 +/- 0.038. Besides, the single column chromatographic separation realized high decontamination factor of U (1.8 x 10(6) to 1.7 x 10(7)), and that ensured the interference effect of U-238 to the Np-237, Pu-239 and Pu-240 measurements was negligible or could be easily corrected. Four standard reference materials were analyzed for method validation, and the results illustrated Pu-242 was an effective non-isotopic tracer for Np-237 determination. Finally, the developed method was successfully employed in the analysis of the global fallout level of Np-237 and Pu isotopes in Japanese paddy soil samples to study their environmental behaviors.
引用
收藏
页码:597 / 604
页数:8
相关论文
共 33 条
  • [1] [Anonymous], 2014, CRC Handbook of Chemistry and Physics, V95th, P3, DOI DOI 10.1201/B17118
  • [2] The role of mass spectrometry in radioactive contamination assessment after the Fukushima nuclear accident
    Bu, Wenting
    Ni, Youyi
    Steinhauser, Georg
    Zheng, Wang
    Zheng, Jian
    Furuta, Naoki
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (04) : 519 - 546
  • [3] MIGRATION OF FALLOUT PU-239+240, AM-241 AND CS-137 IN THE VARIOUS HORIZONS OF A FOREST SOIL UNDER PINE
    BUNZL, K
    KRACKE, W
    SHIMMACK, W
    AUERSWALD, K
    [J]. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1995, 28 (01) : 17 - 34
  • [4] 242Pu as tracer for simultaneous determination of 237Np and 239,240Pu in environmental samples
    Chen, QJ
    Dahlgaard, H
    Nielsen, SP
    Aarkrog, A
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 253 (03) : 451 - 458
  • [5] Sequential determination of Am, Cm, Pu, Np and U by extraction chromatography
    Desideri, Donatella
    Feduzi, Laura
    Meli, Maria Assunta
    Roselli, Carla
    [J]. MICROCHEMICAL JOURNAL, 2011, 97 (02) : 264 - 268
  • [6] Plutonium age determination from 240Pu/236U ratios in individual particles by ICP-MS without prior chemical separation
    Esaka, Fumitaka
    Suzuki, Daisuke
    Miyamoto, Yutaka
    Magara, Masaaki
    [J]. MICROCHEMICAL JOURNAL, 2015, 118 : 69 - 72
  • [7] Inhibitory effect of anti-HER-2 anti-CD3 bi-specific antibody on the growth of gastric carcinoma
    Fang, XD
    Ren, H
    Zhang, Y
    Wang, GJ
    [J]. CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2006, 22 (02) : 193 - 196
  • [8] Analytical atomic spectrometry for nuclear forensics
    Hou, XD
    Chen, W
    He, YH
    Jones, BT
    [J]. APPLIED SPECTROSCOPY REVIEWS, 2005, 40 (03) : 245 - 267
  • [9] Critical comparison of radiometric and mass spectrometric methods for the determination of radionuclides in environmental, biological and nuclear waste samples
    Hou, Xiaolin
    Roos, Per
    [J]. ANALYTICA CHIMICA ACTA, 2008, 608 (02) : 105 - 139
  • [10] International Atomic Energy Agency, 2010, TECH REP, V472, P1