Comparison of Biomechanical Properties of Native Menisci and Bacterial Cellulose Implant

被引:20
作者
Tanaka, Martin L. [1 ,2 ]
Vest, Nikolaj [3 ]
Ferguson, Cristin M. [2 ]
Gatenholm, Paul [3 ,4 ]
机构
[1] Western Carolina Univ, Dept Engn & Technol, Cullowhee, NC 28723 USA
[2] Wake Forest Univ, Dept Orthopaed Surg, Winston Salem, NC 27109 USA
[3] Chalmers, Dept Chem & Biol Engn, S-41296 Gothenburg, Sweden
[4] BC Genesis LLC, Blacksburg, VA USA
基金
美国国家科学基金会;
关键词
Bovine meniscus; Gluconactobacter xylinus; human meniscus; ovine meniscus; suture retention test; tensile testing; MECHANICAL-PROPERTIES; FOLLOW-UP; KNEE; MENISCECTOMY; TENSILE;
D O I
10.1080/00914037.2014.886226
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The menisci are crescent shaped fibrocartilaginous structures in the knee that may become damaged due to traumatic injury or degeneration resulting in pain and a loss of joint function. The goal of this study is to evaluate the mechanical properties of bacterial cellulose (BC) produced by Gluconacetobacter xylinus as a meniscus implants and compare it to native menisci from pigs, sheep, and human. The modulus of BC was varied by controlling water content and tested at four different stiffness values. The modulus of BC ranged from 2.2MPa for native hydrogel (1% cellulose) to 242MPa for BC with 30% cellulose. SEM showed a much denser network as the cellulose content increased. Suture retention tests gave a load to break of 20N and 30N for 10% and 20% BC, respectively. This study shows promising results for the potential use of BC as a meniscus implant.
引用
收藏
页码:891 / 897
页数:7
相关论文
共 28 条
  • [1] Mechanical properties of bacterial cellulose and interactions with smooth muscle cells
    Bäckdahl, H
    Helenius, G
    Bodin, A
    Nannmark, U
    Johansson, BR
    Risberg, B
    Gatenholm, P
    [J]. BIOMATERIALS, 2006, 27 (09) : 2141 - 2149
  • [2] Tendon augmentation grafts: Biomechanical failure loads and failure patterns
    Barber, F. Alan
    Herbert, Morley A.
    Coons, David A.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (05) : 534 - 538
  • [3] BARDANA D, 2000, OPER TECH ORTHOP, V10, P183
  • [4] Bacterial cellulose as a potential meniscus implant
    Bodin, Aase
    Concaro, Sebastian
    Brittberg, Mats
    Gatenholm, Paul
    [J]. JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2007, 1 (05) : 406 - 408
  • [5] Fifteen-year follow-up of arthroscopic partial meniscectomy
    Burks, RT
    Metcalf, MH
    Metcalf, RW
    [J]. ARTHROSCOPY, 1997, 13 (06): : 673 - 679
  • [6] Ewing J.W., 1990, Articular cartilage and knee joint function: basic science and arthroscopy
  • [7] KNEE JOINT CHANGES AFTER MENISCECTOMY
    FAIRBANK, TJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1948, 30 (04): : 664 - 670
  • [8] FITHIAN DC, 1990, CLIN ORTHOP RELAT R, P19
  • [9] GROOT JH, 1990, COLLOID POLYM SCI, V268, P1073
  • [10] DEGENERATIVE CHANGES IN KNEE AFTER MENISCECTOMY
    JACKSON, JP
    [J]. BRITISH MEDICAL JOURNAL, 1968, 2 (5604) : 525 - &