Influence of the constructive features of RC existing buildings in their ductility and seismic performance

被引:7
|
作者
Requena-Garcia-Cruz, Maria-Victoria [1 ]
Morales-Esteban, Antonio [1 ,2 ]
Durand-Neyra, Percy [1 ,2 ]
Zapico-Blanco, Beatriz [1 ]
机构
[1] Univ Seville, Dept Bldg Struct & Geotech Engn, Ave Reina Mercedes 2, Seville 41012, Spain
[2] Univ Seville, Inst Univ Arquitectura & Ciencias Construcc, Ave Reina Mercedes 2, Seville 41012, Spain
关键词
Reinforced concrete buildings; Nonlinear static analysis; Finite element method; Ductility; Behaviour factor; Damage level probability; PLASTIC-DAMAGE MODEL; CAPACITY SPECTRUM METHOD; FORCE REDUCTION FACTORS; BEHAVIOR FACTOR; CONCRETE BUILDINGS; OVERSTRENGTH; DESIGN; FRAMES; SHEAR;
D O I
10.1007/s10518-020-00984-z
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
This paper aims to analyse the ductility of existing buildings to evaluate its influence in their seismic performance. This has been achieved through the retrospective analysis of an existing building in accordance with current seismic codes. This study has revealed the lack of guidance in the NCSE02 and the EC8 regarding the assessment of the ductility of existing buildings. This manuscript proposes a methodology to assess the ductility of Spanish existing buildings. For this purpose, this paper has implemented the American code procedure combined with the EC8 and the Spanish seismic code (NCSE02) requirements. A two-storey RC frame school located in the Spanish region of Huelva has been selected as a case study. Different versions of this school have been compared: as built, designed according to current best practice, EC8 provisions and NCSE02 provisions. To do so, different constructive features have been varied according to each of the ductility class requirements: geometrical properties and the reinforcement ratio of the structural elements. Nonlinear static analyses have been carried out to obtain the displacement ductility factor (mu) and the behaviour factor (q) of each model. Construction costs and the expected damage index have been determined and compared. Results have shown that the best performance, regarding the ductility and the costs, has been obtained with the models designed with deep beams. Conversely, models with wide beams, and where only the reinforcement ratios have been varied, have merely shown a slight enhancement of the resistant and ductile capacity. It has been concluded that the ductility affects the shear capacity, the seismic performance and the expected damage of RC buildings.
引用
收藏
页码:377 / 401
页数:25
相关论文
共 50 条
  • [31] Numerical Assessment of an Innovative RC-Framed Skin for Seismic Retrofit Intervention on Existing Buildings
    Talledo, Diego Alejandro
    Rocca, Irene
    Pozza, Luca
    Savoia, Marco
    Saetta, Anna
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [32] Nonlinear Seismic Analysis of Existing RC School Buildings: The "P3" School Typology
    Estevao, Joao M. C.
    Esteves, Carlos
    BUILDINGS, 2020, 10 (11) : 1 - 16
  • [33] Seismic performance evaluation of different strategies for retrofitting RC frame buildings
    Zhao, Jianchen
    Qiu, Hongxing
    Sun, Jian
    Jiang, Hongbo
    STRUCTURES, 2021, 34 : 2355 - 2366
  • [34] Seismic vulnerability assessment of RC buildings with setback irregularity
    Mouhine, Mohamed
    Hilali, Elmokhtar
    AIN SHAMS ENGINEERING JOURNAL, 2022, 13 (01)
  • [35] Seismic Performance Evaluation of RC Buildings Using Irregularity Based Indices
    Usta, Pinar
    Bozdag, Ozgur
    Onat, Ozge
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2022, 29 (04): : 1362 - 1371
  • [36] Seismic performance assessment of piping systems in bare and infilled RC buildings
    Blasi, Gianni
    Perrone, Daniele
    Aiello, Maria Antonietta
    Pecce, Maria Rosaria
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 149
  • [37] Seismic overstrength and ductility of concrete buildings reinforced with superelastic shape memory alloy rebar
    Alam, M. Shahria
    Moni, M.
    Tesfamariam, S.
    ENGINEERING STRUCTURES, 2012, 34 : 8 - 20
  • [38] The ductility reduction factor in the seismic design of buildings
    Lam, N
    Wilson, J
    Hutchinson, G
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1998, 27 (07): : 749 - 769
  • [39] Influence of Structural Walls on the Seismic Performance of RC Buildings during the May 19, 2011 Simav Earthquake in Turkey
    Avsar, Ozgur
    Tunaboyu, Onur
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2014, 28 (04)
  • [40] Masonry infilling effect on seismic vulnerability and performance level of high ductility RC frames
    Ghalehnovi, M.
    Shahraki, H.
    2008 SEISMIC ENGINEERING CONFERENCE COMMEMORATING THE 1908 MESSINA AND REGGIO CALABRIA EARTHQUAKE, PTS 1 AND 2, 2008, 1020 : 1727 - 1737