MR-acoustic radiation force imaging (MR-ARFI) and susceptibility weighted imaging (SWI) to visualize calcifications in ex vivo swine brain

被引:11
|
作者
Bitton, Rachel R. [1 ]
Butts, Kim R. [1 ]
机构
[1] Stanford Univ, Dept Radiol, Sch Med, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
MR-ARFI; acoustic radiation force; MR-HIFU; MR guided focused ultrasound; calcification; susceptibility weighted;
D O I
10.1002/jmri.24255
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To present the use of MR-acoustic radiation force imaging (MR-ARFI) and susceptibility weighted imaging (SWI) to visualize calcifications in ex vivo brain tissue as a planning indicator for MR-guided focused ultrasound (MRgFUS). Materials and Methods Calcifications were implanted in ex vivo swine brain and imaged using SWI, MR-ARFI, and computed tomography (CT). SWI-filtered phase images used 3D gradient recalled echo (GRE) images with a Fourier-based unwrapping algorithm. The MR-ARFI pulse sequence used a 2DFT spin-echo with repeated bipolar encoding gradients in the direction of the longitudinal ultrasound beam. MR-ARFI interrogations scanned a subregion (14 x 10 x 12 mm) of the brain surrounding the calcification. They were combined into a single displacement weighted map, using the sum of squares method. Calcification size estimates were based on image profiles plotted along the +/- x and +/- z direction, at the full-width half-maximum. Results Both MR-ARFI and SWI were able to visualize the calcifications. The contrast ratio was 150 for CT, 12 for SWI, and 12 for MR-ARFI. Profile measures were 1.35 x 1.28 mm on CT, 1.24 x 1.73 mm on SWI, and 2.45 x 3.02 mm on MR-ARFI. MR-ARFI displacement showed a linear increase with acoustic power (20-80W), and also increased with calcification size. Conclusion The use of SWI-filtered phase and MR-ARFI have the potential to provide a clinical indicator of calcification relevance in the planning of a transcranial MRgFUS treatment. J. Magn. Reson. Imaging 2014;39:1294-1300. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:1294 / 1300
页数:7
相关论文
共 10 条
  • [1] Magnetic Resonance Acoustic Radiation Force Imaging (MR-ARFI)
    Odeen, Henrik
    Payne, Allison H.
    Parker, Dennis L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025,
  • [2] Keyhole acceleration for magnetic resonance acoustic radiation force imaging (MR ARFI)
    Paquin, Raphael
    Vignaud, Alexandre
    Marsac, Laurent
    Younan, Youliana
    Lehericy, Stephane
    Tanter, Mickael
    Aubry, Jean-Francois
    MAGNETIC RESONANCE IMAGING, 2013, 31 (10) : 1695 - 1703
  • [3] ACOUSTIC RADIATION FORCE IMPULSE IMAGING OF HUMAN PROSTATES EX VIVO
    Zhai, Liang
    Madden, John
    Foo, Wen-Chi
    Palmeri, Mark L.
    Mouraviev, Vladimir
    Polascik, Thomas J.
    Nightingale, Kathryn R.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (04) : 576 - 588
  • [4] Improving in situ acoustic intensity estimates using MR acoustic radiation force imaging in combination with multifrequency MR elastography
    Li, Ningrui
    Gaur, Pooja
    Quah, Kristin
    Pauly, Kim Butts
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (04) : 1673 - 1689
  • [5] Simultaneous MR thermometry and acoustic radiation force imaging using interleaved acquisition
    de Bever, Joshua T.
    Odeen, Henrik
    Hofstetter, Lorne W.
    Parker, Dennis L.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1515 - 1524
  • [6] A simulation technique for 3D MR-guided acoustic radiation force imaging
    Payne, Allison
    de Bever, Josh
    Farrer, Alexis
    Coats, Brittany
    Parker, Dennis L.
    Christensen, Douglas A.
    MEDICAL PHYSICS, 2015, 42 (02) : 674 - 684
  • [7] High sensitivity MR acoustic radiation force imaging using transition band balanced steady-state free precession
    Zheng, Yuan
    Marx, Michael
    Miller, G. Wilson
    Pauly, Kim Butts
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1532 - 1537
  • [8] Acoustic radiation force impulse imaging of thermally- and chemically-induced lesions in soft tissues: Preliminary ex vivo results
    Fahey, BJ
    Nightingale, KR
    Stutz, DL
    Trahey, GE
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (03) : 321 - 328
  • [9] Evaluation of a Three-Dimensional MR Acoustic Radiation Force Imaging Pulse Sequence Using a Novel Unbalanced Bipolar Motion Encoding Gradient
    de Bever, Joshua T.
    Odeen, Henrik
    Todd, Nick
    Farrer, Alexis I.
    Parker, Dennis L.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) : 803 - 813
  • [10] Reduced-field of view three-dimensional MR acoustic radiation force imaging with a low-rank reconstruction for targeting transcranial focused ultrasound
    Luo, Huiwen
    Sigona, Michelle K.
    Manue, Thomas J.
    Phipps, Marshal A.
    Chen, Li M.
    Caskey, Charles F.
    Grissom, William A.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) : 2419 - 2431