Influence of Rectangular Ribs on Exergetic Performance in a Triangular Duct Solar Air Heater

被引:20
作者
Nidhul, Kottayat [1 ]
Kumar, Sachin [1 ]
Yadav, Ajay Kumar [1 ]
Anish, S. [1 ]
机构
[1] Natl Inst Technol Karnataka, Dept Mech Engn, Adv Heat Transfer Lab, Surathkal 575025, India
关键词
solar air heater; triangular duct; artificial roughness; rectangular rib; thermal efficiency; entropy generation; exergetic efficiency; energy efficiency; energy systems; extended surfaces; fins; forced convection; heat exchangers; heat transfer enhancement; FRICTION FACTOR CORRELATIONS; 2ND LAW OPTIMIZATION; FORCED-CONVECTION; ARTIFICIAL ROUGHNESS; FLOW; ENERGY; PLATE; OPERATION; COLLECTOR; COEFFICIENT;
D O I
10.1115/1.4046057
中图分类号
O414.1 [热力学];
学科分类号
摘要
Several artificial roughness (ribs) configurations have been used in flat plate solar air heaters (SAH) in recent years to improve their overall performance. In the present work, energy and exergy analyses of rectangular ribs in a triangular duct SAH for varying relative rib heights (e/D = 0.02-0.04), relative rib pitches (P/e = 5-15), and rib aspect ratios (e/w = 0.5-4) are evaluated and compared with smooth SAH. The analysis reveals that the entropy generated due to heat transfer is lower for the ribbed triangular duct compared to the smooth duct. It is also observed that the width of the rib plays a crucial role in minimizing heat losses to the environment. A maximum reduction of 43% and 62% in exergy losses to the environment and exergy losses due to heat transfer to the fluid is achieved, respectively, with a rib aspect ratio (e/w) of 4 compared to the smooth plate. It is found that in contrast to the smooth plate, ribs beneath the absorber plate effectively improves thermal and exergetic efficiency. Maximum enhancement of 36% and 17% is obtained in exergetic efficiency (eta (ex)) and thermal efficiency (eta (th)), respectively, for e/w = 4, P/e = 10 and e/D = 0.04. Results also show the superiority of the ribbed triangular duct over the ribbed rectangular duct for an application requiring compact SAH with a higher flowrate.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Heat transfer augmentation and flow characteristics in ribbed triangular duct solar air heater: An experimental analysis
    Bharadwaj, Gaurav
    Varun
    Kumar, Rajneesh
    Sharma, Avdhesh
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2017, 14 (07) : 587 - 598
  • [32] Exergetic performance evaluation of solar air heater having arc shape oriented protrusions as roughness element
    Yadav, Sanjay
    Kaushal, Maneesh
    Varun
    Siddhartha
    SOLAR ENERGY, 2014, 105 : 181 - 189
  • [33] Performance Evaluation of a Solar Air Heater Roughened with Conic-Curve Profile Ribs Based on Efficiencies and Entropy Generation
    Nguyen Minh Phu
    Nguyen Van Hap
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2020, 45 (11) : 9023 - 9035
  • [34] Numerical solution of solar air heater with triangular corrugations for indirect solar dryer: Influence of pitch and an optimized pitch of corrugation for enhanced performance
    Prajapati, Shivam
    Naik, Namith
    Chandramohan, V. P.
    SOLAR ENERGY, 2022, 243 : 1 - 12
  • [35] Analysis of exergetic performance for a solar air heater with metal foam fins
    Farhan, Ammar A.
    Obaid, Zain Alabdeen H.
    Hussien, Sally Q.
    HEAT TRANSFER, 2020, 49 (05) : 3190 - 3204
  • [36] Thermal performance analysis of semicircular and triangular cross-sectioned duct solar air heaters under external recycle
    Singh, Satyender
    JOURNAL OF ENERGY STORAGE, 2018, 20 : 316 - 336
  • [37] Exergetic performance estimation for roughened triangular duct used in solar air heaters
    Sunil Kumar
    Rajneesh Kumar
    Varun Goel
    Suvanjan Bhattacharyya
    Alibek Issakhov
    Journal of Thermal Analysis and Calorimetry, 2021, 145 : 1661 - 1672
  • [38] Performance Investigation of a Triangular Solar Air Heater Duct Having Broken Inclined Roughness Using Computational Fluid Dynamics
    Jain, Sheetal Kumar
    Das Agrawal, Ghanshyam
    Misra, Rohit
    Verma, Prateek
    Rathore, Sanjay
    Jamuwa, Doraj Kamal
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (06):
  • [39] CFD based performance analysis of a solar air heater duct provided with artificial roughness
    Kumar, Sharad
    Saini, R. P.
    RENEWABLE ENERGY, 2009, 34 (05) : 1285 - 1291
  • [40] Thermohydraulic performance assessment of a solar air heater with equilateral-triangular, trapezoidal, and square sectional ribs on the absorber plate: A comparative study
    Al-Chlaihawi, Kadhim K. Idan
    Hasan, Moayed R.
    Ekaid, Ali L.
    HEAT TRANSFER, 2024, 53 (02) : 441 - 471