A German Chlamydia trachomatis screening program employing semi-automated real-time PCR: results and perspectives

被引:0
|
作者
Boehm, I. [1 ]
Groening, A. [1 ]
Sommer, B. [1 ]
Mueller, H. -W [1 ]
Krawczak, M. [2 ]
Glaubitz, R. [3 ,4 ]
机构
[1] Gynakol Humangenet & Pathol GmbH, MVZ Wagnerstibbe Lab Med, D-30159 Hannover, Germany
[2] Univ Kiel, Inst Med Informat & Stat, D-24105 Kiel, Germany
[3] MVZ Inst Labormed, D-45127 Essen, Germany
[4] Klin Genet Rhein Ruhr GmbH, D-45127 Essen, Germany
关键词
Chlamydia trachomatis; Screening; Real-time PCR; Pooling; Public health; SEXUALLY-TRANSMITTED-DISEASES; LIGASE CHAIN-REACTION; NEISSERIA-GONORRHOEAE; COBAS AMPLICOR; URINE SPECIMENS; PREGNANT-WOMEN; UNITED-KINGDOM; 1ST-VOID URINE; VAGINAL SWABS; PREVALENCE;
D O I
暂无
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Genital Chlamydia trachomatis infection is a worldwide public health burden. A screening program for C trachomatis was therefore initiated by the public health insurers in Germany ("Gemeinsamer Bundesausschuss", GBA) in April 2008. Objectives: To estimate C trachomatis prevalence from screening 115,766 asymptomatic females and 20,033 female patients with unspecific abdominal pain. Study design: Urine samples (pooled by five for the asymptomatic screening subjects) and cervical swabs were analyzed using semi-automated real-time PCR. Infection prevalence was determined separately in four categories of women, defined by health status (asymptomatic screening vs. non-screening with unspecified symptoms) and test material used. Comparative analyses were stratified by age and pregnancy status. Results: Experimental evaluation of the assay used revealed a detection limit of 379 genome copies/ml urine. For pooled urine samples, the positive predictive value was 100% whereas the negative predictive value equaled 98.1%. The observed infection prevalence was higher for cervical swabs than for urine samples. Prevalence estimates also differed significantly between pregnant and non-pregnant adolescents (<= 20 years), irrespective of the test material used (10.2% vs. 7.3% for cervical swabs, 10.9% vs. 6.1% for pooled urine samples). Conclusions: Our retrospective study, based upon a very large number of females from all parts of Germany, revealed a high infection prevalence in adolescents, particularly in pregnant adsolescents, thereby justifying the screening directive of the German GBA. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:S27 / S32
页数:6
相关论文
共 24 条
  • [1] Comparison of three real-time PCR assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in young pregnant women
    Peuchant, Olivia
    de Diego, Sabrina
    Le Roy, Chloe
    Frantz-Blancpain, Sandrine
    Hocke, Claude
    Bebear, Cecile
    de Barbeyrac, Bertille
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2015, 83 (04) : 335 - 337
  • [2] Real-time PCR for pharmacodynamic studies of Chlamydia trachomatis
    Storm, M
    Gustafsson, I
    Herrmann, B
    Engstrand, L
    JOURNAL OF MICROBIOLOGICAL METHODS, 2005, 61 (03) : 361 - 367
  • [3] Evaluation of a Multiplex Real-Time PCR Assay for Detecting Chlamydia trachomatis in Vaginal Samples
    Kebbi-Beghdadi, Carole
    Aeby, Sebastien
    Baud, David
    Greub, Gilbert
    DIAGNOSTICS, 2022, 12 (05)
  • [4] Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs
    Pickering, Harry
    Holland, Martin J.
    Last, Anna R.
    Burton, Matthew J.
    Burr, Sarah E.
    PARASITES & VECTORS, 2018, 11
  • [5] Development, validation and testing costs of an in-house real-time PCR assay for the detection of Chlamydia trachomatis
    dos Santos, Camila Gurgel
    Sabido, Meritxell
    Leturiondo, Andre Luiz
    Ferreira, Cynthia de Oliveira
    da Cruz, Thielle Pereira
    Benzaken, Adele Schwartz
    JOURNAL OF MEDICAL MICROBIOLOGY, 2017, 66 (03) : 312 - 317
  • [6] Real-time High Resolution Melting PCR for identification of the Swedish variant of Chlamydia trachomatis
    Raherison, Sophie
    Clerc, Maithe
    Trombert, Sabine
    Cado, Sylvie
    Normandin, Francoise
    Bebear, Christiane
    de Barbeyrac, Bertille
    JOURNAL OF MICROBIOLOGICAL METHODS, 2009, 78 (01) : 101 - 103
  • [7] Screening for Chlamydia trachomatis in Egyptian women with unexplained infertility, comparing real-time PCR techniques to standard serology tests: case control study
    Abdella, Rana M. A.
    Abdelmoaty, Hatem I.
    Elsherif, Rasha H.
    Sayed, Ahmed Mahmoud
    Sherif, Nadine Alaa
    Gouda, Hisham M.
    El Lithy, Ahmed
    Almohamady, Maged
    Abdelbar, Mostafa
    Hosni, Ahmed Naguib
    Magdy, Ahmed
    Youssef, M. A.
    BMC WOMENS HEALTH, 2015, 15
  • [8] Evaluation of a Chlamydia trachomatis-specific, commercial, real-time PCR for use with ocular swabs
    Harry Pickering
    Martin J. Holland
    Anna R. Last
    Matthew J. Burton
    Sarah E. Burr
    Parasites & Vectors, 11
  • [9] Development of multiplex real-time quantitative PCR for simultaneous detection of Chlamydia trachomatis and Ureaplasma parvum
    Wei, Hong-bo
    Zou, She-xiao
    Yang, Xiao-lin
    Yang, Dai-qin
    Chen, Xiang-dong
    CLINICAL BIOCHEMISTRY, 2012, 45 (09) : 663 - 667
  • [10] Performance assessment of the Allplex™ STI Essential real-time PCR assay for the diagnosis of Neisseria gonorrhoeae and Chlamydia trachomatis infections in genital and extra-genital sites
    Robinet, Sylvain