Data consistency based rigid motion artifact reduction in fan-beam CT

被引:69
|
作者
Yu, Hengyong [1 ]
Wang, Ge [1 ]
机构
[1] Univ Iowa, CT Micro CT Lab, Dept Radiol, Iowa City, IA 52242 USA
基金
美国国家卫生研究院;
关键词
computed tomography (CT); fan-beam; Helgason-Ludwig consistency condition; motion artifact reduction; motion estimation;
D O I
10.1109/TMI.2006.889717
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
It is well known that a rigid in-plane motion can be decomposed into a translation and a rotation around an origin. Based on our previous work, we first extend the Helgason-Ludwig consistency condition (HLCC) to cover a general rigid motion in fan-beam geometry. Then, we model the general motion by several parameters, and develop an iterative scheme for estimation of the in-plane motion parameters. This scheme determines the motion parameters by numerically minimizing an objective function constructed based on the HLCC. After the motion parameters are estimated, image reconstruction can be performed to compensate for the motion effects. Finally, we implement the algorithm and evaluate its performance in numerical simulations.
引用
收藏
页码:249 / 260
页数:12
相关论文
共 50 条
  • [1] Data consistency based translational motion artifact reduction in fan-beam CT
    Yu, Hengyong
    Wei, Yuchuan
    Hsieh, Jiang
    Wang, Ge
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (06) : 792 - 803
  • [2] In-plane motion estimation for artifact reduction in fan-beam CT
    Yu, Hengyong
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [3] Rigid motion artifact reduction in CT using extended difference function
    Zhang, Yuan
    Zhang, Liyi
    Sun, Yunshan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (02) : 273 - 285
  • [4] Data consistency condition for truncated projections in fan-beam geometry
    Yu, Hengyong
    Wang, Ge
    Yang, Jiansheng
    Pack, Jed D.
    Jiang, Ming
    De Man, Bruno
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (05) : 627 - 638
  • [5] A Rigid Motion Artifact Reduction Method for CT Based on Blind Deconvolution
    Zhang, Yuan
    Zhang, Liyi
    ALGORITHMS, 2019, 12 (08)
  • [6] Rigid Motion Artifact Reduction in CT Using the Phase Correlation Method
    Zhang, Yuan
    Zhang, Liyi
    Sun, Yunshan
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2020, 13 (08) : 1119 - 1128
  • [7] Dynamic bowtie for fan-beam CT
    Liu, Fenglin
    Wang, Ge
    Cong, Wenxiang
    Hsieh, Scott S.
    Pelc, Norbert J.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (04) : 579 - 590
  • [8] Motion compensated fan-beam reconstruction for nonrigid transformation
    Taguchi, Katsuyuki
    Kudo, Hiroyuki
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (07) : 907 - 917
  • [9] Rigid motion artifact reduction in CT using frequency domain analysis
    Zhang, Yuan
    Zhang, Liyi
    Sun, Yunshan
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (05) : 721 - 736
  • [10] Method for measuring the intensity profile of a CT fan-beam filter
    Whiting, Bruce R.
    Dohatcu, Andreea
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033