Benefits and Risks of Prophylactic Cerebrospinal Fluid Catheter and Evoked Potential Monitoring in Symptomatic Spinal Cord Ischemia Low-Risk Thoracic Endovascular Aortic Repair

被引:34
作者
Maier, Sven [1 ,2 ]
Shcherbakova, Maria [1 ,2 ]
Beyersdorf, Friedhelm [1 ,2 ]
Benk, Christoph [1 ,2 ]
Kari, Fabian Alexander [1 ,2 ]
Siepe, Matthias [1 ,2 ]
Czerny, Martin [1 ,2 ]
Rylski, Bartosz [1 ,2 ]
机构
[1] Univ Heart Ctr Freiburg, Dept Cardiovasc Surg, Hugstetter Str 55, D-79106 Freiburg, Germany
[2] Univ Freiburg, Fac Med, Freiburg, Germany
关键词
thoracic endovascular aortic repair; cerebrospinal fluid; cerebrospinal fluid catheter; evoked potential monitoring; symptomatic spinal cord ischemia; DRAINAGE; INJURY; COMPLICATIONS; TEVAR;
D O I
10.1055/s-0038-1642611
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background To assess risks and benefits of a standardized strategy to prevent symptomatic spinal cord ischemia (SSCI) after thoracic endovascular repair (TEVAR) using routine cerebrospinal fluid (CSF) catheter placement and evoked potential (EP) monitoring. Methods One hundred and ninety-five patients underwent 223 SSCI low-risk TEVAR procedures between 1998 and 2014. CSF catheter was used to measure CSF pressure and drain CSF if necessary throughout the procedure and up to 24 hours thereafter. EPs were used to monitor spinal cord integrity throughout the procedure. Results Underlying pathologies included descending thoracic aortic aneurysm in 115 (52%), type B aortic dissection in 85 (38%), traumatic aortic rupture in 16 (7%), and others in 7 (3%) patients. CSF catheter was inserted before TEVAR in 116 procedures (52%). Active CSF draining was required in 29 patients (25%). The CSF catheter caused no major and 11 (10%) minor complications. EP were monitored during 88 (40%) procedures. We observed a reduction in the amplitude, prolonged latencies, or complete signal loss in nine procedures. There were no EP monitoring-related complications. SSCI incidence was higher in patients without CSF drainage (0.8% vs 4.7%, p =0.031). Conclusion Use of CSF drainage is associated with a significant lower incidence of SSCI after SSCI low-risk TEVAR than nonuse, whereas the complication rate associated with CSF drainage insertion or removal is very low. Routine EP monitoring is a useful tool to detect immediate arterial inflow obstruction to the spinal cord. The combination of these two methods serves as a safe and reliable standardized strategy in reducing the incidence of SSCI to a minimum.
引用
收藏
页码:379 / 384
页数:6
相关论文
共 15 条
  • [1] Pro: Patients at Risk for Spinal Cord Ischemia After Thoracic Endovascular Aortic Repairs Should Receive Prophylactic Cerebrospinal Fluid Drainage
    Arora, Harendra
    Ullery, Brant W.
    Kumar, Priya A.
    Cheung, Albert T.
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (05) : 1376 - 1380
  • [2] Neuromonitoring, Cerebrospinal Fluid Drainage, and Selective Use of Iliofemoral Conduits to Minimize Risk of Spinal Cord Injury During Complex Endovascular Aortic Repair
    Banga, Peter V.
    Oderich, Gustavo S.
    de Souza, Leonardo Reis
    Hofer, Jan
    Gonzalez, Meaghan L. Cazares
    Pulido, Juan N.
    Cha, Stephen
    Gloviczki, Peter
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (01) : 139 - 149
  • [3] Mechanisms of Symptomatic Spinal Cord Ischemia After TEVAR: Insights From the European Registry of Endovascular Aortic Repair Complications (EuREC)
    Czerny, Martin
    Eggebrecht, Holger
    Sodeck, Gottfried
    Verzini, Fabio
    Cao, Piergiorgio
    Maritati, Gabriele
    Riambau, Vicente
    Beyersdorf, Friedhelm
    Rylski, Bartosz
    Funovics, Martin
    Loewe, Christian
    Schmidli, Juerg
    Tozzi, Piergiorgio
    Weigang, Ernst
    Kuratani, Toru
    Livi, Ugolino
    Esposito, Giampiero
    Trimarchi, Santi
    van den Berg, Jos C.
    Fu, Weiguo
    Chiesa, Roberto
    Melissano, Germano
    Bertoglio, Luca
    Lonn, Lars
    Schuster, Ingrid
    Grimm, Michael
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (01) : 37 - 43
  • [4] Contemporary spinal cord protection during thoracic and thoracoabdominal aortic surgery and endovascular aortic repair: a position paper of the vascular domain of the European Association for Cardio-Thoracic Surgery
    Etz, Christian D.
    Weigang, Ernst
    Hartert, Marc
    Lonn, Lars
    Mestres, Carlos A.
    Di Bartolomeo, Roberto
    Bachet, Jean E.
    Carrel, Thierry P.
    Grabenwoeger, Martin
    Schepens, Marc A. A. M.
    Czerny, Martin
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2015, 47 (06) : 943 - 957
  • [5] Results With Selective Preoperative Lumbar Drain Placement for Thoracic Endovascular Aortic Repair
    Hanna, Jennifer M.
    Andersen, Nicholas D.
    Aziz, Hamza
    Shah, Asad A.
    McCann, Richard L.
    Hughes, G. Chad
    [J]. ANNALS OF THORACIC SURGERY, 2013, 95 (06) : 1968 - 1975
  • [6] Strategies to improve spinal cord ischemia in endovascular thoracic aortic repair: Outcomes of a prospective cerebrospinal fluid drainage protocol
    Hnath, Jeffrey C.
    Mehta, Manish
    Taggert, John B.
    Sternbach, Yaron
    Roddy, Sean P.
    Kreienberg, Paul B.
    Ozsvath, Kathleen J.
    Chang, Benjamin B.
    Shah, Dhiraj M.
    Darling, R. Clement, III
    [J]. JOURNAL OF VASCULAR SURGERY, 2008, 48 (04) : 836 - 840
  • [7] Con: Patients at Risk for Spinal Cord Ischemia After Thoracic Endovascular Aortic Repairs Should Not Receive Prophylactic Cerebrospinal Fluid Drainage
    Isaak, Robert S.
    Furman, William
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (05) : 1381 - 1383
  • [8] Safety of intraoperative transcranial electrical stimulation motor evoked potential monitoring
    MacDonald, DB
    [J]. JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2002, 19 (05) : 416 - 429
  • [9] Spinal cord ischemia after endovascular aortic repair versus open surgical repair for descending thoracic and thoracoabdominal aortic aneurism
    Maeda, Takuma
    Yoshitani, Kenji
    Sato, Shunsuke
    Matsuda, Hitoshi
    Inatomi, Yuzuru
    Tomita, Yukihiko
    Ogino, Hitoshi
    Ohnishi, Yoshihiko
    [J]. JOURNAL OF ANESTHESIA, 2012, 26 (06) : 805 - 811
  • [10] Spinal Cord Injury is Not Negligible after TEVAR for Lower Descending Aorta
    Matsuda, H.
    Fukuda, T.
    Iritani, O.
    Nakazawa, T.
    Tanaka, H.
    Sasaki, H.
    Minatoya, K.
    Ogino, H.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 39 (02) : 179 - 186